All Categories
History
Product
FA sensor Photoelectric sensor (beam sensor) ・Laser sensor Compact/long distance laser distance measurement sensor HG-F1Handling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Analog output | Analog voltage output Output impedance | Analog voltage output output range | Analog current output output range | Analog current output Load resistance | Timer time | Timer function | Teaching function | Hysteresis | Beam diameter | Usage altitude | Light source | Control output NPN transistor open collector | Control output Output operation | Control output short circuit protection | External input | External input function | Response time | Pollution degree | Current consumption | Temperature characteristics | Measurable range | Linearity | Repeatability | Environmental resistance Operating ambient temperature | Environmental resistance Protective structure | Displayable range | Overvoltage category | Compliance regulations and certifications | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
HG-F13A-A-N |
Available upon quote |
Voltage output/current output switching type (initial value: voltage output) |
100Ω |
• Normal: 0V~+5V Distance range can be set by setting (Initial value: 250~3,000mm) |
• Normal: +4mA~+20mA Distance range can be set by setting (Initial value: 250~3,000mm) |
250Ω or less |
5ms / 10ms / 25ms / 50ms / 100ms / 250ms / 500ms / 1,000ms / 5,000ms switchable (initial value: 5ms) |
OFF / On delay / Off delay / One shot switching type (default value: OFF) |
Normal detection mode (2 points / limit), window comparator mode (1 point / 2 points / 3 points) switching type (initial value: normal detection mode) |
30mm (factory setting) Variable up to a minimum of 1mm in PRO mode |
Approximately ø10mm (typical value) (at a measurement distance of 1,000mm) |
2,000m or less |
Red semiconductor laser class 1 [IEC / EN / JIS / GB / KS / FDA] Maximum output: 0.39mW, emission peak wavelength: 680nm |
• Maximum inflow current: 50mA |
Switchable: ON when light is received / ON when no light is received (default value: ON when light is received) |
Equipment (automatic return type) |
NPN non-contact input |
Zero set/teaching/light emission stop switching type (Initial value: zero set) |
35ms / 100ms / 300ms / 2,000ms switchable (initial value: 100ms) |
2 |
40mA or less (at power supply voltage 24V DC) |
0.1% F.S./°C |
250~3,000mm |
±2% F.S. (However, at a measurement distance of 500 to 3,000 mm) |
Within 10mm (on white matte paper □200mm) |
-10~+45℃ (no condensation or freezing), Storage: -20~+60℃ |
IP67 (IEC) |
200~3,300mm |
Category I |
CE marking (EMC directive, RoHS directive), UKCA marking (EMC regulation, RoHS regulation), FDA regulation, TÜV SÜD certification (USA/Canada) |
24V DC±10% including ripple P-P10% |