Product
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)Handling Company
OVAL CorporationCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applicable fluid | Body material | Flange standard | Flow -range liquid (water) | Flow -up range gas (0.2MPa air) | Flow -up range steam (0.5MPa saturated steam) | Maximum use pressure | Nominal diameter | Operating temperature limit | accuracy | output | power supply | structure | type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Battery type VXU |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 600 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 15 ~ 300mm | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Flange -type fixed sensor | |
Battery -type VXT |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 601 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 15 ~ 300mm | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Flange -shaped replesable sensor | |
Battery type VXW |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 602 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 10 ~ 150mm (15mm or more for steam) | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Wafer -shaped fixing sensor (nominal diameter 10-150mm) | |
Battery VXF |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 603 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 15 ~ 300mm | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Flange -shaped fixed sensor (rhuan diameter 15mm or more, RF flange standard) | |
Battery VXR |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 604 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 15 ~ 300mm | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Flange -shaped replacables (RF flange standard, standard RF flange) | |
Battery -type VXJ |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 605 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 10 ~ 150mm (15mm or more for steam) | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Rhinogata -shaped whirlpool -type wafer -shaped fixing sensor | |
Battery VXL |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 606 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 15 ~ 300mm | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Rhinodent whirlpool -type flange -type fixed sensor (order design) | |
Battery type VXM |
Available upon quote | Liquid, gas, steam | SUS316 or SCS14A | JIS 10, 20, 30k ASME/JPI 150, 300, 607 | 0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) | 0.02 ~ 47.6t/h (10 format) (15mm or more) | 4.51MPa (with flange standard and flange material) | 15 ~ 300mm | -30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) | ± 1 % of the amount represented or ± 1 % of the full scale | Analog, pulse | DC power or battery drive | Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) | Rhinodo -shaped vortex flange -type replayable sensor (order design) |
Click on the part number for more information about each product