All Categories
History
Response Rate
100.0%
Response Time
23.1hours
Relatively Fast Response
Product
External power supply that can not be used only with internal batteries EX Delta (standard, battery type, PAF5 type)Handling Company
OVAL CorporationCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | type | Nominal diameter | Flow -range liquid (water) | Flow -up range gas (0.2MPa air) | Flow -up range steam (0.5MPa saturated steam) | Applicable fluid | Operating temperature limit | Flange standard | Maximum use pressure | accuracy | power supply | Body material | structure | output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Battery type VXU |
Available upon quote |
Flange -type fixed sensor |
15 ~ 300mm |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 600 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery -type VXT |
Available upon quote |
Flange -shaped replesable sensor |
15 ~ 300mm |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 601 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery type VXW |
Available upon quote |
Wafer -shaped fixing sensor (nominal diameter 10-150mm) |
10 ~ 150mm (15mm or more for steam) |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 602 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery VXF |
Available upon quote |
Flange -shaped fixed sensor (rhuan diameter 15mm or more, RF flange standard) |
15 ~ 300mm |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 603 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery VXR |
Available upon quote |
Flange -shaped replacables (RF flange standard, standard RF flange) |
15 ~ 300mm |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 604 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery -type VXJ |
Available upon quote |
Rhinogata -shaped whirlpool -type wafer -shaped fixing sensor |
10 ~ 150mm (15mm or more for steam) |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 605 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery VXL |
Available upon quote |
Rhinodent whirlpool -type flange -type fixed sensor (order design) |
15 ~ 300mm |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 606 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
|
Battery type VXM |
Available upon quote |
Rhinodo -shaped vortex flange -type replayable sensor (order design) |
15 ~ 300mm |
0.2 * ~ 2,510m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
2 * ~ 15,000m3/h (11 format) ( * The seal is 10mm and accuracy ± 2 % FS) |
0.02 ~ 47.6t/h (10 format) (15mm or more) |
Liquid, gas, steam |
-30 ~ + 300 ° C, -30 ~ + 460 ° C (for high temperature of replayable sensors) |
JIS 10, 20, 30k ASME/JPI 150, 300, 607 |
4.51MPa (with flange standard and flange material) |
± 1 % of the amount represented or ± 1 % of the full scale |
DC power or battery drive |
SUS316 or SCS14A |
Explosion or non -explosion, IP66 (DC power supply), IP65 (battery drive) |
Analog, pulse |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.