Product
Plug-in-type digital instruction PH meter WIL-102-PHHandling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry UseItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Calibration function 1 | Calibric function 2 | Conformity standard | Contact output (Options: EVT) 1 | External dimensions | Instruction accuracy | Linearness | Measurement range (rated scale) | Peripheral humidity | Protective structure | Repetition | Self -diagnostic function | Serial communication | Serial communication and communication protocol | Serial communication cable length | Serial communication communication line | Serial communication communication method | Serial communication communication speed | Serial communication data bit/Parity | Serial communication error correction | Serial communication error detection | Serial communication format | Serial communication stop bit | Serial communication synchronous method | Temperature compensation element | Temperature compensation range | mass | power supply | structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WIL-102-PH, EVT |
Available upon quote | 0 to 50 ℃ |
2 Automatic proofreading or manual proofreading ・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others ・ Manual proofreading: Optional 2 pH or higher |
Temperature school regular (1 point) | ROHS command support |
As a contact output, select by key operation from among the following 1 ・ No movement ・ PH input limit operation ・ PH input upper limited operation ・ Temperature input limit operation ・ Temperature input upper limited operation |
W30XH88XD108mm (including socket) | Temperature: ± 1 ℃ | PH value: ± 0.05 pH |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH ・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃ |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | PH value: ± 0.05 pH | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ PH, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-PH, TA |
Available upon quote | 0 to 50 ℃ |
2 Automatic proofreading or manual proofreading ・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others ・ Manual proofreading: Optional 2 pH or higher |
Temperature school regular (1 point) | ROHS command support |
As a contact output, select by key operation from among the following 1 ・ No movement ・ PH input limit operation ・ PH input upper limited operation ・ Temperature input limit operation ・ Temperature input upper limited operation |
W30XH88XD108mm (including socket) | Temperature: ± 1 ℃ | PH value: ± 0.05 pH |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH ・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃ |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | PH value: ± 0.05 pH | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ PH, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-PH, TA2 |
Available upon quote | 0 to 50 ℃ |
2 Automatic proofreading or manual proofreading ・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others ・ Manual proofreading: Optional 2 pH or higher |
Temperature school regular (1 point) | ROHS command support |
As a contact output, select by key operation from among the following 1 ・ No movement ・ PH input limit operation ・ PH input upper limited operation ・ Temperature input limit operation ・ Temperature input upper limited operation |
W30XH88XD108mm (including socket) | Temperature: ± 1 ℃ | PH value: ± 0.05 pH |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH ・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃ |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | PH value: ± 0.05 pH | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ PH, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-PH1, EVT |
Available upon quote | 0 to 50 ℃ |
2 Automatic proofreading or manual proofreading ・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others ・ Manual proofreading: Optional 2 pH or higher |
Temperature school regular (1 point) | ROHS command support |
As a contact output, select by key operation from among the following 1 ・ No movement ・ PH input limit operation ・ PH input upper limited operation ・ Temperature input limit operation ・ Temperature input upper limited operation |
W30XH88XD108mm (including socket) | Temperature: ± 1 ℃ | PH value: ± 0.05 pH |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH ・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃ |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | PH value: ± 0.05 pH | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ PH, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-PH1, TA |
Available upon quote | 0 to 50 ℃ |
2 Automatic proofreading or manual proofreading ・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others ・ Manual proofreading: Optional 2 pH or higher |
Temperature school regular (1 point) | ROHS command support |
As a contact output, select by key operation from among the following 1 ・ No movement ・ PH input limit operation ・ PH input upper limited operation ・ Temperature input limit operation ・ Temperature input upper limited operation |
W30XH88XD108mm (including socket) | Temperature: ± 1 ℃ | PH value: ± 0.05 pH |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH ・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃ |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | PH value: ± 0.05 pH | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ PH, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
|
WIL-102-PH1, TA2 |
Available upon quote | 0 to 50 ℃ |
2 Automatic proofreading or manual proofreading ・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others ・ Manual proofreading: Optional 2 pH or higher |
Temperature school regular (1 point) | ROHS command support |
As a contact output, select by key operation from among the following 1 ・ No movement ・ PH input limit operation ・ PH input upper limited operation ・ Temperature input limit operation ・ Temperature input upper limited operation |
W30XH88XD108mm (including socket) | Temperature: ± 1 ℃ | PH value: ± 0.05 pH |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH ・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃ |
35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | PH value: ± 0.05 pH | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Perform the following operations from the external computer. ・ Read and set various set values ・ PH, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9,600, 19,200, 38,400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend |
・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) |
ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) | 0.0 to 100.0 ° C | Approximately 200g (including socket) | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray ・ Panel: Membrane sheet |
Click on the part number for more information about each product