Plug-in-type digital instruction PH meter WIL-102-PH-WIL-102-PH, EVT
Plug-in-type digital instruction PH meter WIL-102-PH-Shinko Technos Co., Ltd.

Plug-in-type digital instruction PH meter WIL-102-PH
Shinko Technos Co., Ltd.


About This Product

This is a digital instruction pH meter that is installed on the DIN rail in the control panel that supports various purposes such as top water, drainage, training equipment, and building equipment. ・ DIN rail mounting type ・ Various settings and calibration operations are possible via communication (RS-485) ・ Compatible with model approval (SS121) ・ 24 V power supply (by specified form name) ・ Equipped with cleaning output function ・ 2 points of transmission output (optional)

  • Product

    Plug-in-type digital instruction PH meter WIL-102-PH




*Please note that we may not be able to accommodate sample requests.

6 Models of Plug-in-type digital instruction PH meter WIL-102-PH

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Calibration function 1 Calibric function 2 Conformity standard Contact output (Options: EVT) 1 External dimensions Instruction accuracy Linearness Measurement range (rated scale) Peripheral humidity Protective structure Repetition Self -diagnostic function Serial communication Serial communication and communication protocol Serial communication cable length Serial communication communication line Serial communication communication method Serial communication communication speed Serial communication data bit/Parity Serial communication error correction Serial communication error detection Serial communication format Serial communication stop bit Serial communication synchronous method Temperature compensation element Temperature compensation range mass power supply structure
Plug-in-type digital instruction PH meter WIL-102-PH-Part Number-WIL-102-PH, EVT

WIL-102-PH, EVT

Available upon quote 0 to 50 ℃ 2 Automatic proofreading or manual proofreading
・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others
・ Manual proofreading: Optional 2 pH or higher
Temperature school regular (1 point) ROHS command support As a contact output, select by key operation from among the following 1
・ No movement
・ PH input limit operation
・ PH input upper limited operation
・ Temperature input limit operation
・ Temperature input upper limited operation
W30XH88XD108mm (including socket) Temperature: ± 1 ℃ PH value: ± 0.05 pH ・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH
・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) PH value: ± 0.05 pH Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ PH, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) 0.0 to 100.0 ° C Approximately 200g (including socket) 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ DIN rail mounting method
・ Case: flame -retardant resin color: Light gray
・ Panel: Membrane sheet
Plug-in-type digital instruction PH meter WIL-102-PH-Part Number-WIL-102-PH, TA

WIL-102-PH, TA

Available upon quote 0 to 50 ℃ 2 Automatic proofreading or manual proofreading
・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others
・ Manual proofreading: Optional 2 pH or higher
Temperature school regular (1 point) ROHS command support As a contact output, select by key operation from among the following 1
・ No movement
・ PH input limit operation
・ PH input upper limited operation
・ Temperature input limit operation
・ Temperature input upper limited operation
W30XH88XD108mm (including socket) Temperature: ± 1 ℃ PH value: ± 0.05 pH ・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH
・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) PH value: ± 0.05 pH Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ PH, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) 0.0 to 100.0 ° C Approximately 200g (including socket) 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ DIN rail mounting method
・ Case: flame -retardant resin color: Light gray
・ Panel: Membrane sheet
Plug-in-type digital instruction PH meter WIL-102-PH-Part Number-WIL-102-PH, TA2

WIL-102-PH, TA2

Available upon quote 0 to 50 ℃ 2 Automatic proofreading or manual proofreading
・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others
・ Manual proofreading: Optional 2 pH or higher
Temperature school regular (1 point) ROHS command support As a contact output, select by key operation from among the following 1
・ No movement
・ PH input limit operation
・ PH input upper limited operation
・ Temperature input limit operation
・ Temperature input upper limited operation
W30XH88XD108mm (including socket) Temperature: ± 1 ℃ PH value: ± 0.05 pH ・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH
・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) PH value: ± 0.05 pH Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ PH, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) 0.0 to 100.0 ° C Approximately 200g (including socket) 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ DIN rail mounting method
・ Case: flame -retardant resin color: Light gray
・ Panel: Membrane sheet
Plug-in-type digital instruction PH meter WIL-102-PH-Part Number-WIL-102-PH1, EVT

WIL-102-PH1, EVT

Available upon quote 0 to 50 ℃ 2 Automatic proofreading or manual proofreading
・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others
・ Manual proofreading: Optional 2 pH or higher
Temperature school regular (1 point) ROHS command support As a contact output, select by key operation from among the following 1
・ No movement
・ PH input limit operation
・ PH input upper limited operation
・ Temperature input limit operation
・ Temperature input upper limited operation
W30XH88XD108mm (including socket) Temperature: ± 1 ℃ PH value: ± 0.05 pH ・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH
・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) PH value: ± 0.05 pH Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ PH, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) 0.0 to 100.0 ° C Approximately 200g (including socket) 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ DIN rail mounting method
・ Case: flame -retardant resin color: Light gray
・ Panel: Membrane sheet
Plug-in-type digital instruction PH meter WIL-102-PH-Part Number-WIL-102-PH1, TA

WIL-102-PH1, TA

Available upon quote 0 to 50 ℃ 2 Automatic proofreading or manual proofreading
・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others
・ Manual proofreading: Optional 2 pH or higher
Temperature school regular (1 point) ROHS command support As a contact output, select by key operation from among the following 1
・ No movement
・ PH input limit operation
・ PH input upper limited operation
・ Temperature input limit operation
・ Temperature input upper limited operation
W30XH88XD108mm (including socket) Temperature: ± 1 ℃ PH value: ± 0.05 pH ・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH
・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) PH value: ± 0.05 pH Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ PH, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) 0.0 to 100.0 ° C Approximately 200g (including socket) 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ DIN rail mounting method
・ Case: flame -retardant resin color: Light gray
・ Panel: Membrane sheet
Plug-in-type digital instruction PH meter WIL-102-PH-Part Number-WIL-102-PH1, TA2

WIL-102-PH1, TA2

Available upon quote 0 to 50 ℃ 2 Automatic proofreading or manual proofreading
・ 2 points Automatic School Shoji: Automatic Power Director Stability Judgment, Type PH2, 4, 7, 9, 10 (JIS), the combination of standard solution, pH7 and others
・ Manual proofreading: Optional 2 pH or higher
Temperature school regular (1 point) ROHS command support As a contact output, select by key operation from among the following 1
・ No movement
・ PH input limit operation
・ PH input upper limited operation
・ Temperature input limit operation
・ Temperature input upper limited operation
W30XH88XD108mm (including socket) Temperature: ± 1 ℃ PH value: ± 0.05 pH ・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH
・ Temperature: 0.0 to 100.0 ° C, decomposition ability: 0.1 ℃
35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) PH value: ± 0.05 pH Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. Perform the following operations from the external computer.
・ Read and set various set values
・ PH, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Half double communication Select 9,600, 19,200, 38,400 BPS by key operation 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Command resend ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
ASCII, binary Select 1 bit and 2 bits by key operation Toning synchronization ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element PT1000 or PT100) ・ PH composite electrode sensor (PH sensor JIS Z8802 compliant temperature element CU500/25) 0.0 to 100.0 ° C Approximately 200g (including socket) 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ DIN rail mounting method
・ Case: flame -retardant resin color: Light gray
・ Panel: Membrane sheet

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree