Digital instructions dissolved oxygen Aer-102-DO-AER-102-DO, C5
Digital instructions dissolved oxygen Aer-102-DO-Shinko Technos Co., Ltd.

Digital instructions dissolved oxygen Aer-102-DO
Shinko Technos Co., Ltd.

♻️ Environment & Recycling Use 🧪 Chemical Industry Use 💊 Pharmaceutical & Medical Use

Shinko Technos Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

53.0hours


About This Product

A type of digital insolved meter that is installed on the control panel panel that supports various purposes such as top water, drainage, training equipment, and building equipment. ・ 48 × 96mm square, panel mount type ・ Drip -proof / dustproof structure IP66 compatible (front panel) ・ Compatible with power supply voltage 24 v AC/DC (specified by form name) ・ Up to 4 points of contact compatible with proportional control ・ Various settings and calibration operations are possible via communication (RS-485) (optional)

  • Product

    Digital instructions dissolved oxygen Aer-102-DO
  • Usage Scenarios

    Environment & Recycling Use / Chemical Industry Use / Pharmaceutical & Medical Use

Share this product


490+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of Digital instructions dissolved oxygen Aer-102-DO

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Measurement range dissolved oxygen concentration Measurement range dissolved oxygen saturation rate Measurement range oxygen division of pressure Measurement range temperature Instruction accuracy Time accuracy Data update cycle Contact output Transmission output 1, 2-1 Transmission output 1, 2-2 Transmission output 1, 2-3 Self -diagnostic function Ambient temperature Peripheral humidity power supply structure Protective structure Conformity standard External dimensions mass Serial communication (Options: C5) Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (Options: C5) Communication method Serial communication (Options: C5) Communication speed Serial communication (Options: C5) Sync Serial communication (Options: C5) Certification format Serial communication (Options: C5) Communication protocol Serial Communication (Options: C5) Data Bit/Parity Serial communication (Options: C5) Stop bit
Digital instructions dissolved oxygen Aer-102-DO-Part Number-AER-102-DO, C5

AER-102-DO, C5

Available upon quote

Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l

Scenery range: 0.0-200.0 %, decomposition ability: 0.1 %

Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa

Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃

Rely on the accuracy of the fluorescent dissolved oxygen detector

Within ± 1%for the set time

5 seconds

・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation

-Dissed oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen subdivision or MV is converted to analog amount for each data update cycle and output by current.

-The transmission output 1 (2) Maximum value and transmission output 1 (2) If the lower limit value is set to the same value, the transmission output 1 (2) is fixed to 4 ma DC.
・ The transmission output volume can be displayed.

・ Resolution: 12,000
・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω)
・ Output accuracy: Transmission output 1 (2) within ± 0.3%of span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

0 to 50 ℃

35 ~ 85%RH (but not condensation)

100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66

Over-pressure category Ⅱ, pollution 2 (IEC61010-1)

ROHS command support

W48XH96XD110mm case depth: 98.5mm (at panel mount)

Approximately 280g

Perform the following operations from the external computer.
・ Read and set various set values
・ Dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen pressure, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9,600, 19,200, 38,400 BPS by key operation

Toning synchronization

ASCII, binary

Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation

8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation

Select 1 bit and 2 bits by key operation

Digital instructions dissolved oxygen Aer-102-DO-Part Number-AER-102-DO, EVT3

AER-102-DO, EVT3

Available upon quote

Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l

Scenery range: 0.0-200.0 %, decomposition ability: 0.1 %

Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa

Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃

Rely on the accuracy of the fluorescent dissolved oxygen detector

Within ± 1%for the set time

5 seconds

・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation

-Dissed oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen subdivision or MV is converted to analog amount for each data update cycle and output by current.

-The transmission output 1 (2) Maximum value and transmission output 1 (2) If the lower limit value is set to the same value, the transmission output 1 (2) is fixed to 4 ma DC.
・ The transmission output volume can be displayed.

・ Resolution: 12,000
・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω)
・ Output accuracy: Transmission output 1 (2) within ± 0.3%of span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

0 to 50 ℃

35 ~ 85%RH (but not condensation)

100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC

・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66

Over-pressure category Ⅱ, pollution 2 (IEC61010-1)

ROHS command support

W48XH96XD110mm case depth: 98.5mm (at panel mount)

Approximately 280g

Perform the following operations from the external computer.
・ Read and set various set values
・ Dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen pressure, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9,600, 19,200, 38,400 BPS by key operation

Toning synchronization

ASCII, binary

Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation

8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation

Select 1 bit and 2 bits by key operation

Digital instructions dissolved oxygen Aer-102-DO-Part Number-AER-102-DO1, C5

AER-102-DO1, C5

Available upon quote

Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l

Scenery range: 0.0-200.0 %, decomposition ability: 0.1 %

Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa

Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃

Rely on the accuracy of the fluorescent dissolved oxygen detector

Within ± 1%for the set time

5 seconds

・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation

-Dissed oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen subdivision or MV is converted to analog amount for each data update cycle and output by current.

-The transmission output 1 (2) Maximum value and transmission output 1 (2) If the lower limit value is set to the same value, the transmission output 1 (2) is fixed to 4 ma DC.
・ The transmission output volume can be displayed.

・ Resolution: 12,000
・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω)
・ Output accuracy: Transmission output 1 (2) within ± 0.3%of span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

0 to 50 ℃

35 ~ 85%RH (but not condensation)

24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC

・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66

Over-pressure category Ⅱ, pollution 2 (IEC61010-1)

ROHS command support

W48XH96XD110mm case depth: 98.5mm (at panel mount)

Approximately 280g

Perform the following operations from the external computer.
・ Read and set various set values
・ Dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen pressure, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9,600, 19,200, 38,400 BPS by key operation

Toning synchronization

ASCII, binary

Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation

8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation

Select 1 bit and 2 bits by key operation

Digital instructions dissolved oxygen Aer-102-DO-Part Number-AER-102-DO1, EVT3

AER-102-DO1, EVT3

Available upon quote

Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l

Scenery range: 0.0-200.0 %, decomposition ability: 0.1 %

Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa

Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃

Rely on the accuracy of the fluorescent dissolved oxygen detector

Within ± 1%for the set time

5 seconds

・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation

-Dissed oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen subdivision or MV is converted to analog amount for each data update cycle and output by current.

-The transmission output 1 (2) Maximum value and transmission output 1 (2) If the lower limit value is set to the same value, the transmission output 1 (2) is fixed to 4 ma DC.
・ The transmission output volume can be displayed.

・ Resolution: 12,000
・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω)
・ Output accuracy: Transmission output 1 (2) within ± 0.3%of span

Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality.

0 to 50 ℃

35 ~ 85%RH (but not condensation)

24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC

・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66

Over-pressure category Ⅱ, pollution 2 (IEC61010-1)

ROHS command support

W48XH96XD110mm case depth: 98.5mm (at panel mount)

Approximately 280g

Perform the following operations from the external computer.
・ Read and set various set values
・ Dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen pressure, temperature, state reading
・ Change and adjust function
・ Reading and setting of user storage area

1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides)

EIA RS-485 compliant

Half double communication

Select 9,600, 19,200, 38,400 BPS by key operation

Toning synchronization

ASCII, binary

Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation

8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation

Select 1 bit and 2 bits by key operation

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Dissolved Oxygen Analyzers Products

Other products of Shinko Technos Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

53.0hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree