Digital instructions dissolved oxygen Aer-102-DO-Shinko Technos Co., Ltd.

AER-102-DO1, C5 | Digital instructions dissolved oxygen Aer-102-DO
Shinko Technos Co., Ltd.


Price (excluding tax)

Estimate Required


Model Description

・ Input number: 2 points ・ Input: fluorescent dissolved oxygen detector ・ Power supply voltage: 24 V AC/DC ・ Options: Serial communication RS-485


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Ambient temperature

Conformity standard

Contact output

Data update cycle

External dimensions

Instruction accuracy

Measurement range dissolved oxygen concentration

Measurement range dissolved oxygen saturation rate

Measurement range oxygen division of pressure

Measurement range temperature

Peripheral humidity

Protective structure

Self -diagnostic function

Serial Communication (Options: C5) Data Bit/Parity

Serial communication (Options: C5)

Serial communication (Options: C5) Certification format

Serial communication (Options: C5) Communication method

Serial communication (Options: C5) Communication protocol

Serial communication (Options: C5) Communication speed

Serial communication (Options: C5) Stop bit

Serial communication (Options: C5) Sync

Serial communication (option: C5) cable length

Serial communication (option: C5) communication line

Time accuracy

Transmission output 1, 2-1

Transmission output 1, 2-2

Transmission output 1, 2-3

mass

power supply

structure

See all 4 models in list
  • Part Number

    AER-102-DO1, C5




*Please note that we may not be able to accommodate sample requests.

Digital instructions dissolved oxygen Aer-102-DO AER-102-DO1, C5's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Ambient temperature Conformity standard Contact output Data update cycle External dimensions Instruction accuracy Measurement range dissolved oxygen concentration Measurement range dissolved oxygen saturation rate Measurement range oxygen division of pressure Measurement range temperature Peripheral humidity Protective structure Self -diagnostic function Serial Communication (Options: C5) Data Bit/Parity Serial communication (Options: C5) Serial communication (Options: C5) Certification format Serial communication (Options: C5) Communication method Serial communication (Options: C5) Communication protocol Serial communication (Options: C5) Communication speed Serial communication (Options: C5) Stop bit Serial communication (Options: C5) Sync Serial communication (option: C5) cable length Serial communication (option: C5) communication line Time accuracy Transmission output 1, 2-1 Transmission output 1, 2-2 Transmission output 1, 2-3 mass power supply structure
Digital instructions dissolved oxygen Aer-102-DO-Part Number-AER-102-DO1, C5 Available upon quote 0 to 50 ℃ ROHS command support ・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation 5 seconds W48XH96XD110mm case depth: 98.5mm (at panel mount) Rely on the accuracy of the fluorescent dissolved oxygen detector Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l Scenery range: 0.0-200.0 %, decomposition ability: 0.1 % Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃ 35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Perform the following operations from the external computer. ・ Read and set various set values ・ Dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen pressure, temperature, state reading ・ Change and adjust function ・ Reading and setting of user storage area ASCII, binary Half double communication Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation Select 9,600, 19,200, 38,400 BPS by key operation Select 1 bit and 2 bits by key operation Toning synchronization 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant Within ± 1%for the set time -Dissed oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen subdivision or MV is converted to analog amount for each data update cycle and output by current. -The transmission output 1 (2) Maximum value and transmission output 1 (2) If the lower limit value is set to the same value, the transmission output 1 (2) is fixed to 4 ma DC. ・ The transmission output volume can be displayed. ・ Resolution: 12,000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: Transmission output 1 (2) within ± 0.3%of span Approximately 280g 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66

There are 4 models for this product.

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Shinko Technos Co., Ltd.

  • Japan
  • Since 1945
  • 185 employees

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree