Power adjustment instrument power controller PA-200Handling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Food Industry Use / Electronics & Electrical Use / Chemical Industry UseClick on the part number for more information about each product
Image | Part Number | Price (excluding tax) | control method | Phase | Rated current | input signal | Rated voltage | Output adjustment range | Slope adjustment range | Voltage fluctuation range | Soft -up | External dimensions W x H x D (mm) | Mounting method | Calorific value | Ambient temperature | mass | accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PA-2100-H |
Available upon quote |
Phase control method |
Single-phase |
100A |
4 ~ 20mA DC, relay contact input, manual setting, 0.8 ~ 4V DC |
100/110V AC, 200/220V AC 50/60Hz |
0 to 98% of rated voltage |
0 ~ 100% (DAMP) |
Within ± 10%of the rated voltage |
0.2 ~ 5 seconds variable (0.2 seconds when the factory is shipped) |
155 x 228 x 157 |
Surface mounting method |
100W |
Operation temperature: 0 to 60 ° C (allowed current reduction at 40 ° C or higher) |
3.5kg |
1 part of the instruction manual |
|
PA-215-Z |
Available upon quote |
Zero cross -wander control method |
Single-phase |
15A |
4 ~ 20mA DC, relay contact input, manual setting, 0.8 ~ 4V DC |
100/110V AC, 200/220V AC 50/60Hz |
0 to 98% of rated voltage |
0 ~ 100% (DAMP) |
Within ± 10%of the rated voltage |
- |
60 × 178 × 152 |
Surface mounting method |
22W |
Operation temperature: 0 to 60 ° C (allowed current reduction at 40 ° C or higher) |
1.0kg |
1 part of the instruction manual |
|
PA-230-Z |
Available upon quote |
Zero cross -wander control method |
Single-phase |
30A |
4 ~ 20mA DC, relay contact input, manual setting, 0.8 ~ 4V DC |
100/110V AC, 200/220V AC 50/60Hz |
0 to 98% of rated voltage |
0 ~ 100% (DAMP) |
Within ± 10%of the rated voltage |
- |
60 × 178 × 152 |
Surface mounting method |
36W |
Operation temperature: 0 to 60 ° C (allowed current reduction at 40 ° C or higher) |
1.1kg |
1 part of the instruction manual |
|
PA-260-Z |
Available upon quote |
Zero cross -wander control method |
Single-phase |
60A |
4 ~ 20mA DC, relay contact input, manual setting, 0.8 ~ 4V DC |
100/110V AC, 200/220V AC 50/60Hz |
0 to 98% of rated voltage |
0 ~ 100% (DAMP) |
Within ± 10%of the rated voltage |
- |
124 x 228 x 157 |
Surface mounting method |
60W |
Operation temperature: 0 to 60 ° C (allowed current reduction at 40 ° C or higher) |
3.0kg |
1 part of the instruction manual |
Click on the part number for more information about each product