Product
Indoor -shaped sensor (temperature, humidity, temperature and humidity, CO2) DSW seriesHandling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Architecture & Construction UseItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Environmental specifications | Insulation resistance | Material | Measurement range | Measuring method | Mounting method | Power-supply voltage | Preserved environment | Response characteristics | Sensor correction | Type of element | Withstand voltage | accessories | accuracy | mass | output | power consumption | usage environment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DSW-100-H |
Available upon quote | ROHS command support | Case-between output 500V DC 500mΩ or more | Flame retardant PC resin white | 5 ~ 90%RH | - | Installation on the box cover (JIS-C8340: 1999 Outlet box mounting dimension 66.7mm) | 24V DC ± 10% |
・ Temperature: -20 ~ 60 ° C ・ Humidity: 5 to 90%RH (not condensation) |
About 20 seconds (90%reach of 30⇔ 85%RH) | - | Changing capacity change type | Case-Between output between output 1.5kv 1 minute 1 minute or less |
・ Mounting the body (M3 × 4) 4 ・ 1 ate board ・ Ate board mounting (M4 × 8, spring washer) 2 each ・ 1 part of the instruction manual |
± 5%RH (AT5 ~ 45 ° C) 5 to 45 ° C, maximum ± 8%RH | Approximately 90g | ・ 4 ~ 20 MA DC (linear for 0 to 100%RH) ・ 2 -wire type, 4 -wire type ・ Maximum allowable load: 500Ω or less | ・ 2-wire type: Approximately 550 MW (4 ~ 20 MA DC output) ・ 4-wire type: about 3 W (DSW-100-H W4) |
・ Temperature: 0 to 50 ℃ ・ Humidity: 5 to 90%RH (not condensation) |
|
DSW-100-Tr □ |
Available upon quote | ROHS command support | Case-between output 500V DC 500mΩ or more | Flame retardant PC resin white | 0 to 50 ℃ | - | Installation on the box cover (JIS-C8340: 1999 Outlet box mounting dimension 66.7mm) | Without a power supply |
・ Temperature: -20 ~ 60 ° C ・ Humidity: 5 to 90%RH (not condensation) |
63%response within 1 minute (at the time of wind speed 1.5 m/s) | - | Temperature resistance 100Ω/0 ° C (PT100) (IEC60751 class) | Case-Between output between output 1.5kv 1 minute 1 minute or less |
・ Mounting the body (M3 × 4) 4 ・ 1 ate board ・ Ate board mounting (M4 × 8, spring washer) 2 each ・ 1 part of the instruction manual |
± (0.1+0.0017 | T |) ℃ | Approximately 90g | 100Ω/0 ° C (PT100) 3 -wire type | Approximately 550 MW (4 ~ 20 ma DC output) |
・ Temperature: 0 to 50 ℃ ・ Humidity: 5 to 90%RH (not condensation) |
|
DSW-100-TA □ |
Available upon quote | ROHS command support | Case-between output 500V DC 500mΩ or more | Flame retardant PC resin white | 0 to 50 ℃ | - | Installation on the box cover (JIS-C8340: 1999 Outlet box mounting dimension 66.7mm) | 24V DC ± 10% | ・ Temperature: -20 ~ 60 ° C ・ Humidity: 5 to 90%RH (not condensation) | 63%response within 1 minute (at the time of wind speed 1.5 m/s) | - | Temperature resistance 100Ω/0 ° C (PT100) (IEC60751 class) | Case-Between output between output 1.5kv 1 minute 1 minute or less |
・ Mounting the body (M3 × 4) 4 ・ 1 ate board ・ Ate board mounting (M4 × 8, spring washer) 2 each ・ 1 part of the instruction manual |
± 0.5 ℃ | Approximately 90g |
・ 4 ~ 20 MA DC (linear for 0 to 50 ° C) ・ Select 2 -wire type and 4 -wire type ・ Maximum allowable load: 500Ω or less |
・ 2-wire type: Approximately 550 MW (4 ~ 20 MA DC output) ・ 4 wire: Approximately 4 W (DSW-100-TA W4, DSW-100-TAH W4) |
・ Temperature: 0 to 50 ℃ ・ Humidity: 5 to 90%RH (not condensation) |
|
DSW-100-Tah □ |
Available upon quote | ROHS command support | Case-between output 500V DC 500mΩ or more | Flame retardant PC resin white | Temperature: 0 ~ 50, humidity: 5 ~ 90%RH | - | Installation on the box cover (JIS-C8340: 1999 Outlet box mounting dimension 66.7mm) | 24V DC ± 10% |
・ Temperature: -20 ~ 60 ° C ・ Humidity: 5 to 90%RH (not condensation) |
・ Temperature: 63%in 1 minute (wind speed 1.5 m/s at time) ・ Humidity: about 20 seconds (90%of RH of 30⇔ 85%RH) | - | ・ Temperature: Measurement temperature resistor 100Ω/0 ° C (PT100) (IEC60751 class) ・ Humidity: Changing capacity change type | Case-Between output between output 1.5kv 1 minute 1 minute or less |
・ Mounting the body (M3 × 4) 4 ・ 1 ate board ・ Ate board mounting (M4 × 8, spring washer) 2 each ・ 1 part of the instruction manual |
・ Temperature: ± 0.5 ° C ・ Humidity: ± 5%RH (AT5 ~ 45 ° C) 5 to 45 ° C, maximum ± 8%RH | Approximately 90g | Temperature: 4 to 20mA DC (linear against 0 to 50 ° C) Humidity: 4 ~ 20mA DC or 0 to 1V DC (linear for 0 to 100%RH) Select 4 -wire type, maximum allowable load. : 500Ω or less | ・ 2-wire type: Approximately 550 MW (4 ~ 20 MA DC output) ・ 4 wire: Approximately 4 W (DSW-100-TA W4, DSW-100-TAH W4) |
・ Temperature: 0 to 50 ℃ ・ Humidity: 5 to 90%RH (not condensation) |
|
DSW-100-TRHV W4 |
Available upon quote | ROHS command support | Case-between output 500V DC 500mΩ or more | Flame retardant PC resin white | Temperature: 0 ~ 50, humidity: 5 ~ 90%RH | - | Installation on the box cover (JIS-C8340: 1999 Outlet box mounting dimension 66.7mm) | 24V DC ± 10% |
・ Temperature: -20 ~ 60 ° C ・ Humidity: 5 to 90%RH (not condensation) |
・ Temperature: 63%in 1 minute (at the time of wind speed 1.5 m/s) ・ Humidity: about 20 seconds (90%of RH of 30⇔ 85%RH) |
- |
・ Temperature: Temperature resistance body 100Ω/0 ° C (PT100) (IEC60751 class) ・ Humidity: Changing capacity change type |
Case-Between output between output 1.5kv 1 minute 1 minute or less |
・ Mounting the body (M3 × 4) 4 ・ 1 ate board ・ Ate board mounting (M4 × 8, spring washer) 2 each ・ 1 part of the instruction manual |
・ Temperature: ± (0.1+0.0017 | T |) ℃ ・ Humidity: ± 5%RH (AT5 ~ 45 ° C) 5 to 45 ° C, maximum ± 8%RH |
Approximately 90g | Temperature: 100Ω/0 ° C (PT100) 3 -wire humidity: 0 ~ 1V DC (linear for 0 to 100%RH), 4 -wire type, maximum allowable load: 500Ω or less. | Approximately 4 w |
・ Temperature: 0 to 50 ℃ ・ Humidity: 5 to 90%RH (not condensation) |
|
DSW-200-Co2-1 □□ |
Available upon quote | ROHS command support | Case-between output 500V DC 500mΩ or more | Flame retardant PC resin white | 360 ~ 2,000 ppm (with sensor correction function) | Non -disciplined infrared analysis method (NDIR) | Installation on the box cover (JIS-C8340: 1999 Outlet box mounting dimension 66.7mm) | 24V DC ± 10% |
・ Temperature: -30 to 70 ° C ・ Humidity: 0 to 95%RH (not condensation) |
Within 120 seconds | If the 45th day is one cycle and the measured value falls below 400 ppm within that period, the difference between the minimum and 400 ppm within the period is added to the next cycle. | - | Case-Between output between output 1.5kv 1 minute 1 minute or less |
・ Mounting the body (M3 × 4) 4 ・ 1 ate board ・ Ate board mounting (M4 × 8, spring washer) 2 each ・ 1 part of the instruction manual |
・ (50ppm+3%of measured values). ・ Warm up time 30 minutes * Regarding the accuracy described, the accuracy of the factory is not guaranteed. |
Approximately 100 g | ・ DSW-200-CO2-11 □: 4-20mA DC (maximum allowable load 550Ω or less) ・ DSW-200-Co2-12 □: 0 to 20mA DC (maximum allowable load 550Ω or less) ・ DSW-200-CO2-13 □: 1-5V DC (maximum allowable load 5kΩ or more) ・ DSW-200-CO2-14 □: 0 to 5V DC (maximum allowable load 5kΩ or more) ・ DSW-200-CO2-15 □: 0-1V DC (maximum Telegrated load 1kΩ or more) | Approximately 3 w |
・ Temperature: 0 to 50 ℃ ・ Humidity: 0 to 95%RH (not condensation) |
Click on the part number for more information about each product