Module-shaped adjustment meter QX1 Series Control Module QTC1- □-QTC1-2
Module-shaped adjustment meter QX1 Series Control Module QTC1- □-QTC1-4
Module-shaped adjustment meter QX1 Series Control Module QTC1- □-Shinko Technos Co., Ltd.

Module-shaped adjustment meter QX1 Series Control Module QTC1- □
Shinko Technos Co., Ltd.

⚙️ Plastic & Rubber Manufacturing 💻 Electronics & Electrical Use 🔩 Metal Processing Industry Use

About This Product

A module -shaped meter installed in the board that can measure, control, and monitor up to 1,024 points. The combination of control modules and communication expansion modules can flexibly respond to all controls, and can be configured at the minimum cost. ■ Measure and control MAX 1024 points The control module with a regulatory plan for two or four units can be used alone or consolidated. By combining with the top, it can be flexible in the construction of a large to small variety of systems. ■ Contributing to reducing man -hours by PLC programless connection (SIF function) By using the SIF function (Smart interface, PLC programless communication function), you can connect directly to each company PLC. ■ Used as an analog module. Contributing to initial cost reduction+ministry wiring By using the QX1 series as an analog module, initial costs are reduced and contributed to the deployment. ■ Failure prediction conservation The following measurement function can be grasped. ・ Hita accumulation time energization time ・ Countermination time of the module itself ・ Number of relay contact opening and closing. The input difference detection function allows you to monitor the input difference between channels. As an avoidance of risk in case of emergency ・ The output can be switched with the output selection function. ・ Detects the breaking of the heater and outputs the signal. ・ You can output a warning output signal or start/stop control. ■ Power equipment cost reduction with peak power suppression function The total current in the module can be set, and the total of the current value set on each channel can control the power suppression with a value below the total current. Contribute to reducing the investment of power equipment. ■ Contribute to improving the quality of the product ・ Coordinates multiple zones (auto balance control) ・ Individual setting (output gain / bias control) ■ Equipped with 5 control methods to reduce workers' trouble How you want to control is different for each control target. This unit is equipped with five control methods and responds to various requests. ・ 2 Flexible PID control ・ Fast-PID control ・ Slow-PID control ・ GAP-PID control ・ ON-OFF control ■ Improvement of maintenance You can see the state and error on site with many LEDs. * There are other model numbers

  • Product

    Module-shaped adjustment meter QX1 Series Control Module QTC1- □
  • Usage Scenarios

    Plastic & Rubber Manufacturing / Electronics & Electrical Use / Metal Processing Industry Use

Share this product


330+ people viewing

Last viewed: 4 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Module-shaped adjustment meter QX1 Series Control Module QTC1- □

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Communication line Communication method Communication protocol Input sampling cycle Standard accuracy measurement temperature resistor Standard precision current/voltage input Standard precision thermoelectric interpretation 1 Standard precision thermoelectric interpretation 2 Synchronous method communication speed
Module-shaped adjustment meter QX1 Series Control Module QTC1- □-Part Number-QTC1-2

QTC1-2

Available upon quote EIA RS-485 compliant Half double communication MODBUS RTU ・ 20ms (valid only for current/voltage input) ・ 50ms (only for current/voltage input) ・ 125ms ・ In the case of thermoelectric interpretation, measuring temperature resistance input, 125ms fixed regardless of setting. Within 0.1%of each input span at a peripheral temperature of 23 ° C and a mounting angle of ± 5 degrees. Within 0.2%of each input span at a peripheral temperature of 23 ° C and a mounting angle of ± 5 degrees. The surrounding temperature is 23 ° C, the mounting angle is ± 5 degrees ・ within 0.2%of each input span ・ However, for less than 0 ° C (32 ° F), within 0.4%of each input span ・ R, S input 0 ~ 200 ° C (32 ~ 392 ° F) within 6 ° C (12 ° F) ・ B input 0 ~ 300 ° C (32 ~ 572 ° F) outside the accuracy guarantee range. Toning synchronization 9600, 19200, 38400, 57600bps
Module-shaped adjustment meter QX1 Series Control Module QTC1- □-Part Number-QTC1-4

QTC1-4

Available upon quote EIA RS-485 compliant Half double communication MODBUS RTU ・ 20ms (valid only for current/voltage input) ・ 50ms (only for current/voltage input) ・ 125ms ・ In the case of thermoelectric interpretation, measuring temperature resistance input, 125ms fixed regardless of setting. Within 0.1%of each input span at a peripheral temperature of 23 ° C and a mounting angle of ± 5 degrees. Within 0.2%of each input span at a peripheral temperature of 23 ° C and a mounting angle of ± 5 degrees. The surrounding temperature is 23 ° C, the mounting angle is ± 5 degrees ・ within 0.2%of each input span ・ However, for less than 0 ° C (32 ° F), within 0.4%of each input span ・ R, S input 0 ~ 200 ° C (32 ~ 392 ° F) within 6 ° C (12 ° F) ・ B input 0 ~ 300 ° C (32 ~ 572 ° F) outside the accuracy guarantee range. Toning synchronization 9600, 19200, 38400, 57600bps

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.