About This Product

A digital instruction adjustment meter with a compact body, a simple program function and a simple conversion device function. ・ 4 digits LED display ・ Dustproof / drip -proof IP66 ・ Simple program function (9 steps per pattern) ・ Simple conversion device function (input signal → 4 to 20 MADC)

■ Small size

Compact with 48 × 24 × 98.5mm (W × H × D).

■ Multi input

A total of 18 types: thermoelectric vs (10 types), measuring temperature resistors (2 types), DC current (2 types), and DC voltage (4 types). In addition to temperature control of injection molding machines, extruders, bags, packaging machines, dryers, electric furnaces, etc., it can also support various processes that make use of the high speed of 0.25 seconds in input sampling cycle.

■ Event output 2 points

Equipped with two events output (relay contact, open collector) standard equipment. You can select a key operation from the alarm operation, the timer function, and the pattern end function.

■ Simple program controller function

Equipped with 1 pattern/9 -step program controller function. Simple program control can be performed.

■ Conversion device function

The signal of the thermoelectric dating, the measured temperature resistor, the DC current, and the DC voltage input is converted to a 4-20mA DC that is insulated and outputs.

■ Digital input (DI)

SV1/SV2 external switching function, OUT/OFF (Run/STOP) external switching function, timer function can be selected by key operation. ・ SV1/SV2 External switching function: SV1 (main setting 1) and SV2 (main setting 2) can be switched by the signal of the external contact. ・ OUT/OFF (RUN/STOP) External switching function: Out/off of the control of this device can be switched by external contact signals. In the case of program control, you can switch the program execution (RUN) and stop (STOP) by external contact signals. ・ Timer function: When the input signal from the outside is entered, the timer measurement is started, and the operation output of ON delay, OFF delay, or ON/OFF delay is turned on after the delay tyima set time (delay operation is the operation operation. You can choose by key operation).

■ Drip -proof / dustproof structure

It is an front IP66 structure that can be used in a harsh environment where dust and water is applied.

■ Serial communication (optional)

The communication protocol uses the world standard Modbus protocol (Modbus ASCII, Modbus RTU) as our standard and field network. Equipment number and communication protocol can be selected by key operation.

■ Monitor software

The monitor software SWM-JCL01M has functions such as collective display, 1 channel display, and data logging. * There are other model numbers

  • Product

    Digital instruction adjustment meter JCL-33A series (48mm x 24mm square)

Share this product


380+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Digital instruction adjustment meter JCL-33A series (48mm x 24mm square)

Image Part Number Price (excluding tax) Rated range K input input range Rated range J input input range Rated range R input range Rated Range S input range Rated range B input range Rated range E input input range Rated range T input range Rated range N input input range Rated range PL-II input range Rated range C (W/Re5-26) input range Rated range PT100 input range Rated range JPT100 input range Rated range 4 ~ 20 MA DC input range Rated range 0 ~ 20 MA DC input range Rated range 0-1 V DC input range Rated range 0-10 V DC input range Rated range 1 ~ 5 v DC input range Rated range 0 ~ 5 V DC input range display Input thermoelectric dating Input measurement temperature resistor Input DC current Input DC voltage 1 Input DC voltage 2 Accuracy (setting / instructions) Thermotical electricity vs. 1 Accuracy (setting / instructions) Thermotical electricity vs. 2 Accuracy (setting / instructions) Mass -resistant Accuracy (setting / instructions) DC current Accuracy (setting / instructions) DC voltage Input sampling cycle
Digital instruction adjustment meter JCL-33A series (48mm x 24mm square)-Part Number-JCL-33A-A/M 1

JCL-33A-A/M 1

Available upon quote

-200 ~ 1370 ° C/-320 ~ 2500 ° F, -199.9 ~ 400.0 ° C/-199.9 ~ 750.0 ° F

-200 ~ 1000 ° C/-320 ~ 1800 ° F

0 ~ 1760 ° C/0 ~ 3200 ° F

0 ~ 1760 ° C/0 ~ 3200 ° F

0 ~ 1820 ° C/0 ~ 3300 ° F

-200 ~ 800 ° C/-320 ~ 1500 ° F

-199.9 ~ 400.0 ℃/-199.9 ~ 750.0 ° F

-200 ~ 1300 ° C/-320 ~ 2300 ° F

0 ~ 1390 ° C/0 ~ 2500 ° F

0 ~ 2315 ° C/0 ~ 4200 ° F

-200 ~ 850 ° C/-300 ~ 1500 ° F, -199.9 ~ 850.0 ° C/-199.9 ~ 999.9 ° f

-200 ~ 500 ° C/-300 ~ 900 ° F, -199.9 ~ 500.0 ° C/-199.9 ~ 900.0 ° F

-1999 ~ 9999, -199.9 ~ 999.9, -19.99 ~ 99.99, -1.999 ~ 9.999

-1999 ~ 9999, -199.9 ~ 999.9, -19.99 ~ 99.99, -1.999 ~ 9.999

-1999 ~ 9999, -199.9 ~ 999.9, -19.99 ~ 99.99, -1.999 ~ 9.999

-1999 ~ 9999, -199.9 ~ 999.9, -19.99 ~ 99.99, -1.999 ~ 9.999

-1999 ~ 9999, -199.9 ~ 999.9, -19.99 ~ 99.99, -1.999 ~ 9.999

-1999 ~ 9999, -199.9 ~ 999.9, -19.99 ~ 99.99, -1.999 ~ 9.999

PV/SV: [Red 4 digits, character dimensions: 8.7 x 5 mm (height x width)], MEMO/STOP: [Green 1 digit, character dimensions: 8.7 x 5 mm (height x width)]

・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance: 100Ω or less, but in the case of B input, the external resistance is 40Ω or less.

・ PT100, JPT100
・ 3 conductor type (permissible input donductor resistance per line: 10Ω or less)

・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance: 50Ω (Connect the receiving resistor 50Ω between the input terminals.)
・ Available input current: 50mA DC or less (when receiving resistor 50Ω is used)

・ 0 ~ 1V DC
・ Input impedance: 1mΩ or more
・ Tolerance input voltage: 5V DC or less, allowable signal source resistance: 2kΩ or less

・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance: 100kΩ or more
・ Tolerance input voltage: 15V DC or less, allowable signal source resistance: 100Ω or less

・ Within ± 0.2%± 1 digit or within ± 2 ° C (4 ° F) of each input span
・ However, the range of 0 to 200 ° C (32 to 392 ° F) by R or S input is within ± 6 ° C (12 ° F).

・ The range of 0 to 300 ° C (32 ~ 572 ° F) by B input is out of the precision guarantee range.
・ K, J, E, T, N input is less than 0 ° C (32 ° F) within ± 0.4%± 1 digit or ± 4 ° C (8 ° F) of the input span.

Within ± 0.1%± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2%± 1 digit of each input span

Within ± 0.2%± 1 digit of each input span

250ms

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Controllers Products

Other products of Shinko Technos Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

53.0hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree