Digital instruction adjustment meter ACD-13A/ACR-13A-ACD-13A-R/M, EI
Digital instruction adjustment meter ACD-13A/ACR-13A-Shinko Technos Co., Ltd.

Digital instruction adjustment meter ACD-13A/ACR-13A
Shinko Technos Co., Ltd.

⚙️ Plastic & Rubber Manufacturing 🍎 Food Industry Use 💻 Electronics & Electrical Use

About This Product

■ Easy -to -see industry top class large LCD display The LCD display is the industry's top class. ・ ACD-13A PV display: 24.0 x 11.0mm (height x width), SV/MV/TIME display: 14.0 x 7.0mm (height x width) ・ ACR-13A PV display: 14.0 x 5.4mm (height x width), SV/MV/TIME Display: 10.0 x 4.6mm (height x width) ■ You can see the current value (PV) even in control OFF There are four types of control output OFF functions. You can see the current value (PV) even when the control output is OFF, and you can also select alarm output. ■ The amount of output operation can be seen on the burger. 22 dots (-5-105%) burger label display. You can also select the deviation display. ■ Easy setting mode Normally used configuration items can be operated with an up key, down key, and mode key as in the conventional adjustment meter. ■ Abundant input / output event function Event input 4 points (optional), up to 5 points output. In addition to warning output, heater disconnection warning output (optional), loop abnormal alarm output, timer output, time signal output, pattern -end output, you can select arbitrarily select. ■ Power -free USB communication cable If you use an separately sold USB communication cable (CMB-001), the initial settings are not required to the regulator. ■ Drip -proof / dustproof structure It is an front IP66 structure that can be used in a harsh environment where dust and water is applied. * There are other model numbers

  • Product

    Digital instruction adjustment meter ACD-13A/ACR-13A
  • Usage Scenarios

    Plastic & Rubber Manufacturing / Food Industry Use / Electronics & Electrical Use

Share this product


740+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Digital instruction adjustment meter ACD-13A/ACR-13A

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Input DC current Input DC voltage 1 Input DC voltage 2 Input measurement temperature resistor Input thermoelectric dating Measurement range scale -10 ~ 10mv input (decomposition ability 1) Measurement range scale 0 ~ 100mv input (decomposition ability 1) Measurement range scale 0 ~ 10V input (resolution 1) Measurement range scale 0 ~ 10mv input (resolution 1) Measurement range scale 0 ~ 1V input (resolution 1) Measurement range scale 0 ~ 20mA input (resolution 1) Measurement range scale 0 ~ 50mv input (resolution 1) Measurement range scale 0 ~ 5V input (resolution 1) Measurement range scale 1 ~ 5V input (decomposition ability 1) Measurement range scale 4 ~ 20mA input (resolution 1) Measurement range scale C input (decomposition ability 1 ° C/° f) Measurement range scale E input (decomposed ability 1 ° C/° f) Measurement range scale Input (decomposition ability 1 ° C/° f) Measurement range scale N input (decomposed ability 1 ° C/° f) Measurement range scale range B input (decomposed ability 1 ° C/° f) Measurement range scale range J input (decomposed ability 1 ° C/° f) Measurement range scale range JPT100 input (decomposition No ability 0.1 ° C/° f) Measurement range scale range JPT100 input (decomposition ability 1 ° C/° f) Measurement range scale range K input (decomposed ability 1 ℃/° f) Measurement range scale range K input (decomposition No ℃/° f) Measurement range scale range PL-II input (decomposed ability 1 ° C/° f) Measurement range scale range PT100 input (decomposed ability 1 ℃/° f) Measurement range scale range PT100 input (decomposition No ℃/° f) Measurement range scale range R input (decomposition ability 1 ° C/° f) Measurement range scale range T input (decomposition No ℃/° f)
Digital instruction adjustment meter ACD-13A/ACR-13A-Part Number-ACD-13A-R/M, EI

ACD-13A-R/M, EI

Available upon quote ・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance 50Ω, allowable input current 50mA or less
・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC
・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less
・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less
・ PT100, JPT100 3 conductor type
・ Removable value per tolerable resistance value 10Ω or less per line
・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance 100Ω
-2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 0 ~ 2315 ° C/32 ~ 4199 ° F -200 ~ 800 ° C/-328 ~ 1472 ° F 0 ~ 1760 ° C/32 ~ 3200 ° F -200 ~ 1300 ° C/-328 ~ 2372 ° F 0 ~ 1820 ° C/32 ~ 3308 ° F -200 ~ 1000 ° C/-328 ~ 1832 ° F -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F -200 ~ 500 ° C/-328 ~ 932 ° F -200 ~ 1370 ° C/-328 ~ 2498 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F 0 ~ 1390 ° C/32 ~ 2534 ° F -200 ~ 850 ° C/-328 ~ 1562 ° F ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C 0 ~ 1760 ° C/32 ~ 3200 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F
Digital instruction adjustment meter ACD-13A/ACR-13A-Part Number-ACR-13A-R/M, C5

ACR-13A-R/M, C5

Available upon quote ・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance 50Ω, allowable input current 50mA or less
・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC
・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less
・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less
・ PT100, JPT100 3 conductor type
・ Removable value per tolerable resistance value 10Ω or less per line
・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance 100Ω
-2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 0 ~ 2315 ° C/32 ~ 4199 ° F -200 ~ 800 ° C/-328 ~ 1472 ° F 0 ~ 1760 ° C/32 ~ 3200 ° F -200 ~ 1300 ° C/-328 ~ 2372 ° F 0 ~ 1820 ° C/32 ~ 3308 ° F -200 ~ 1000 ° C/-328 ~ 1832 ° F -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F -200 ~ 500 ° C/-328 ~ 932 ° F -200 ~ 1370 ° C/-328 ~ 2498 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F 0 ~ 1390 ° C/32 ~ 2534 ° F -200 ~ 850 ° C/-328 ~ 1562 ° F ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C 0 ~ 1760 ° C/32 ~ 3200 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F
Digital instruction adjustment meter ACD-13A/ACR-13A-Part Number-ACD-13A-R/M 1, A3

ACD-13A-R/M 1, A3

Available upon quote ・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance 50Ω, allowable input current 50mA or less
・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC
・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less
・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less
・ PT100, JPT100 3 conductor type
・ Removable value per tolerable resistance value 10Ω or less per line
・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance 100Ω
-2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 0 ~ 2315 ° C/32 ~ 4199 ° F -200 ~ 800 ° C/-328 ~ 1472 ° F 0 ~ 1760 ° C/32 ~ 3200 ° F -200 ~ 1300 ° C/-328 ~ 2372 ° F 0 ~ 1820 ° C/32 ~ 3308 ° F -200 ~ 1000 ° C/-328 ~ 1832 ° F -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F -200 ~ 500 ° C/-328 ~ 932 ° F -200 ~ 1370 ° C/-328 ~ 2498 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F 0 ~ 1390 ° C/32 ~ 2534 ° F -200 ~ 850 ° C/-328 ~ 1562 ° F ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C 0 ~ 1760 ° C/32 ~ 3200 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F
Digital instruction adjustment meter ACD-13A/ACR-13A-Part Number-ACR-13A-R/M 1, EI, TA1

ACR-13A-R/M 1, EI, TA1

Available upon quote ・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance 50Ω, allowable input current 50mA or less
・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC
・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less
・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less
・ PT100, JPT100 3 conductor type
・ Removable value per tolerable resistance value 10Ω or less per line
・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance 100Ω
-2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 0 ~ 2315 ° C/32 ~ 4199 ° F -200 ~ 800 ° C/-328 ~ 1472 ° F 0 ~ 1760 ° C/32 ~ 3200 ° F -200 ~ 1300 ° C/-328 ~ 2372 ° F 0 ~ 1820 ° C/32 ~ 3308 ° F -200 ~ 1000 ° C/-328 ~ 1832 ° F -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F -200 ~ 500 ° C/-328 ~ 932 ° F -200 ~ 1370 ° C/-328 ~ 2498 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F 0 ~ 1390 ° C/32 ~ 2534 ° F -200 ~ 850 ° C/-328 ~ 1562 ° F ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C 0 ~ 1760 ° C/32 ~ 3200 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F
Digital instruction adjustment meter ACD-13A/ACR-13A-Part Number-ACD-13A-S/M, EI, W

ACD-13A-S/M, EI, W

Available upon quote ・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance 50Ω, allowable input current 50mA or less
・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC
・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less
・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less
・ PT100, JPT100 3 conductor type
・ Removable value per tolerable resistance value 10Ω or less per line
・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance 100Ω
-2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 0 ~ 2315 ° C/32 ~ 4199 ° F -200 ~ 800 ° C/-328 ~ 1472 ° F 0 ~ 1760 ° C/32 ~ 3200 ° F -200 ~ 1300 ° C/-328 ~ 2372 ° F 0 ~ 1820 ° C/32 ~ 3308 ° F -200 ~ 1000 ° C/-328 ~ 1832 ° F -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F -200 ~ 500 ° C/-328 ~ 932 ° F -200 ~ 1370 ° C/-328 ~ 2498 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F 0 ~ 1390 ° C/32 ~ 2534 ° F -200 ~ 850 ° C/-328 ~ 1562 ° F ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C 0 ~ 1760 ° C/32 ~ 3200 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F
Digital instruction adjustment meter ACD-13A/ACR-13A-Part Number-ACR-13A-S/M, DS

ACR-13A-S/M, DS

Available upon quote ・ 0 ~ 20mA DC, 4 ~ 20ma DC
・ Input impedance 50Ω, allowable input current 50mA or less
・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC
・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less
・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC
・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less
・ PT100, JPT100 3 conductor type
・ Removable value per tolerable resistance value 10Ω or less per line
・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26)
・ External resistance 100Ω
-2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 -2000 ~ 10000 0 ~ 2315 ° C/32 ~ 4199 ° F -200 ~ 800 ° C/-328 ~ 1472 ° F 0 ~ 1760 ° C/32 ~ 3200 ° F -200 ~ 1300 ° C/-328 ~ 2372 ° F 0 ~ 1820 ° C/32 ~ 3308 ° F -200 ~ 1000 ° C/-328 ~ 1832 ° F -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F -200 ~ 500 ° C/-328 ~ 932 ° F -200 ~ 1370 ° C/-328 ~ 2498 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F 0 ~ 1390 ° C/32 ~ 2534 ° F -200 ~ 850 ° C/-328 ~ 1562 ° F ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C 0 ~ 1760 ° C/32 ~ 3200 ° F -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree