Fully automatic nucleic acid extraction device-Maglead 5BL
Fully automatic nucleic acid extraction device-Maglead 6GC
Fully automatic nucleic acid extraction device-Maglead 12GC
Fully automatic nucleic acid extraction device-Hitachi High Texification Co., Ltd.

Fully automatic nucleic acid extraction device
Hitachi High Texification Co., Ltd.


About This Product


  • Product

    Fully automatic nucleic acid extraction device




*Please note that we may not be able to accommodate sample requests.

3 Models of Fully automatic nucleic acid extraction device

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) European Directors Extraction time Handling liquid amount Number of simultaneous processing samples Standard accessories Temperature control application option power supply size weight
Fully automatic nucleic acid extraction device-Part Number-Maglead 5BL

Maglead 5BL

Available upon quote - About 70 minutes 1-20ml 1-5 1 SD card
Built -in UV lamp
Heating block: room temperature ~ 95 ° C ± 3 ° C C Genomic DNA extraction from 5 ml of human blood External barcode reader AC100-240 V 50/60 Hz 240 VA H660 x W450 x D670 mm Approximately 40kg
Fully automatic nucleic acid extraction device-Part Number-Maglead 6GC

Maglead 6GC

Available upon quote Medical device for out -of -body diagnostic diagnosis
EU Directive 98/97/EC conformity
About 25 minutes ~/ Run
* The processing time depends on the application.
25 - 1,000 µL 1-6 1 protocol IC card
Built -in UV lamp
Heating block: 40-95 ° C Extracting Total nucleic acid from 200 μL, 400 μL, or 1 ml External barcode reader
PC software
AC100-240 V 50/60 Hz 300 VA H570 x W330 x D510 mm Approximately 30kg
Fully automatic nucleic acid extraction device-Part Number-Maglead 12GC

Maglead 12GC

Available upon quote Medical device for out -of -body diagnostic diagnosis
EU Directive 98/97/EC conformity
About 25 minutes ~/ Run
* The processing time depends on the application.
25 - 1,000 µL 1-12 1 protocol IC card
Built -in UV lamp
Heating block: 40-95 ° C Extracting Total nucleic acid from 200 μL, 400 μL, or 1 ml External barcode reader
PC software
AC100-240 V 50/60 Hz 300 VA H574 x W500 x D535 mm Approximately 55kg

Click on the part number for more information about each product

About Company Handling This Product

Hitachi High Texification Co., Ltd.

  • Japan
  • Since 2000
  • 671 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.