About This Product

■AC adapter (sold separately) can be connected, ideal for long-term measurements

・4,000 counts ・0.5% maximum accuracy ・Capacitance measurement ・Measurement of capacitor capacitance with large leakage current is not possible. ・Data hold/range hold ・Mis-insertion prevention cover (4・10A) ・AC adapter/terminal safety cover ・Optical link USB interface (optional)

  • Product

    Digital multimeter (tester) Data processing (PC connection) PC20

Share this product


140+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Digital multimeter (tester) Data processing (PC connection) PC20

Image Part Number Price (excluding tax) Power supply Battery low warning Battery life DC current measurement range DC current highest accuracy DC current resolution DC voltage measurement range DC voltage highest accuracy DC voltage resolution DC voltage input resistance LCD display Power consumption Automatic polarity display switching Dimensions/mass Operating temperature/humidity Operation method Storage temperature/humidity Operating environment conditions AC current measurement range AC current highest accuracy AC current resolution AC voltage measurement range AC voltage highest accuracy AC voltage resolution AC voltage input resistance AC detection method Range switching Fuse Sample rate Over display
Digital multimeter (tester) Data processing (PC connection) PC20-Part Number-Digital multimeter PC20

Digital multimeter PC20

Available upon quote

R6 (AA battery) 1.5V x 2

The battery mark lights up when the internal battery is exhausted.

Continuous at DCV, approximately 150 hours

400μ/4,000μ/40m/400m/4A/10A

± (1.5%+2)

0.1μA

400m/4/40/400/1,000V

± (0.5%+2)

0.1mV

10M~100MΩ

4,000 counts

Typical value 7mW (at DCV)

Only "-" is displayed when inputting a negative value

H167×W90×D48mm/approx. 330g (with holster attached)

5℃~31℃, 80%RH (max),
At temperatures above 31℃ and 40℃, it decreases linearly from 80%RH to 50%RH.

Δ-Σ method

-10℃~50℃, 70%RH or less (no condensation)

Altitude below 2,000m/Environmental pollution level II

400μ/4,000μ/40m/400m/4A/10A

± (1.8%+5)

0.1μA

4/40/400/750V

± (1.2%+5)

0.001V

10~11MΩ

Average value method

Auto and manual

F1176:0.5A/250V, IR1.5kA, φ5×20mm ceramic tube
F1197:12.5A/250V,IR125A, φ6.3×32mm glass tube

Approximately 3 times/second

OL" is displayed in the numerical part
(Excluding DC1,000V, AC750V, 10A)

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Digital Multimeters Products

Other products of Sanwa Electric Meter Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Sanwa Electric Meter Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

53.8hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree