Biological molecular thermal stability analysis device in solution Microcal DSC series Microcal Peaq-DSC-Microcal Peaq-DSC
Biological molecular thermal stability analysis device in solution Microcal DSC series Microcal Peaq-DSC-Spectory

Biological molecular thermal stability analysis device in solution Microcal DSC series Microcal Peaq-DSC
Spectory


About This Product

Protein stability analysis for the highest level of survey applications The Microcal Peaq-DSC system is a high-sensitivity and easy-to-use microcarolimetry, reducing the time and cost of stability test and equivalent analysis. Microcal Peaq-DSC is a manual device with a cleaning device and can be upgraded to the automatic version according to the request. Data generated by Microcal Peaq-DSC is an important guidance for bio-drug development in research on protein engineering, preparation (preliminary prescription) development, manufacturing method development, manufacturing change, biological similarity and biological equivalency. The integrated software rationalizes workflow, promoting unprecedented data analysis, performance certification, 21 CFR part 11 and Annex 11, which provides highly consistent data by biopharmaceutical research to improve productivity. ■ Overview A radical scanning -type calorieimetry (DSC) is a powerful analysis tool for evaluating the heat stability of proteins and other biomolecular molecules. In this analysis method, the entertainment change (ΔH) of the structural change (ΔH) of the molecular molecule in the solution caused by heat is measured. This information gives a beneficial understanding of proteins, nucleic acids, Micell complexes, and other elements that stabilize or unstable the other macro molecular systems. Data predicts the period of storage of biomolecular products such as biofasmers, enables molecular comparison between batches and bio shrimmer and innovator, develops purification strategies, evaluates and evaluates the characteristics of protein configuration, and ranks ligand similarity in the detection program of low molecular products. Use it for attaching. High-sensitivity Microcal Peaq-DSC systems are equipped with automatic data analysis, supporting highly consistent thermal stability data, complementing legal regulations, and can be easily integrated into existing systems for data processing and transfer. Loading the sample can be operated unmanned, so you can reduce the man -hours of the operator. It is a completely equipped system and does not require additional accessories, reagents, or consumables.

  • Product

    Biological molecular thermal stability analysis device in solution Microcal DSC series Microcal Peaq-DSC




*Please note that we may not be able to accommodate sample requests.

1 Models of Biological molecular thermal stability analysis device in solution Microcal DSC series Microcal Peaq-DSC

Product Image Part Number Price (excluding tax) 21 CFR Part 11 Allowed noise Baseline reproducibility Cell capacity Cell material Cleaning solvent Humidity Maximum scan rate Measurement temperature range Measuring type Multiple feedback mode Network compatible Operation temperature (° C) Pressure intake Carolimetry (PPC) Protection grade (IP) Repetition Reproduction (at non -continuous measurement) Response time Reverse scan Sample processing Sample volume Storage temperature System reproducibility Technology Typical sample concentration cell power supply
Biological molecular thermal stability analysis device in solution Microcal DSC series Microcal Peaq-DSC-Part Number-Microcal Peaq-DSC

Microcal Peaq-DSC

Available upon quote Yes (when using Peaq-Complience software options) 0.05 μCal/° C 2 1 μCal/° C 2 130 μL tantalum Use water and cleaning solution (Contrad 90) as standard 10%to 70%, no condensation (10%to 90%when stored) 240 ° C/h 2 ° C to 130 ° C 2,5 Detactive Medium Dark temperature (TM)
Entelled pee change (ΔH)
Change of heat capacity (ΔCP)
Yes (passive, high -gain, low gain) Yes (when using the e -mail warning function) #ERROR! None -manual cleaning device with a workflow with an operation guide IP21 <0.2µcal/° C 3 <0.08 ° C ST. DEV. TM and ΔH <2%RSD 4 5s 2 can be ≤6 Number of analysis samples/8 hours 250µL (manual filling) -20 ° C ~+50 ° C <0.1 ° C ST. DEV. TM and ΔH <5%RSD 4 Explaning scanning thermo -type carolimetry 0.01 mg/ml to 10 mg/ml 1 Capillary AC100V -240V, 50/60Hz, 70W (cell), provided PC

Other products of Spectory


View more products of Spectory

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.