Ultra -low ripple noise, high -stability fixed voltage power supply ALR seriesHandling Company
FUTEX co., ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Output voltage | Output voltage monitor | Output current monitor | Rated output current | Ripple noise | Ripple voltage monitor | Voltage monitor accuracy | DC stability | Temperature coefficient | Input fluctuation rate | Load variable rate | Output setting | External input | Protection circuit | Input voltage | control method | Switching method | Boosting system | Outer diameter dimensions | Output voltage control manual | Output voltage control remote | Protection function ① | Protection function ➁ | Output display | usage environment | accessories | option |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ALR503- □ |
Available upon quote |
0.1kv ~ 50kv |
D-Sub connector: 0 to 50kv → 0-10V |
D-Sub connector: 0 to 250μA → 0-10V |
250μA MAX |
Less than 5 ppm (250mVP-P) @50kv/100 μA |
Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) |
± 0.1%or less (5kv to 50kV) |
10ppm/h or less |
10ppm/℃ or less |
Within 20 ppm for fluctuation of AC input voltage ± 10% |
50 ppm or less @ fluctuations in total load at maximum output voltage |
10 -rotation potenthameter (coarse) & (Fine (fine tone)) |
BNC terminal: 0-10V → 0 to 50kv |
Over -voltage: 55kV, overcurrent protection: 275 μA |
Single -phase 100VAC ± 10% 50/60Hz |
Continent voltage control |
Freback Pushpur method + soft switching + soft start |
Freback Trans + Symmetric Cock Croft / Walton Circuit |
482W x 88H x 452D |
Front panel COARSE (rough tone) and FINE (fine tone) |
External control voltage 0VDC ~+10VDC, or external output control BOX (optional) |
Over -voltage protection (110%rated) Over Volt. LED lighting / overcurrent protection (110%rated) Over Current. LED lighting |
Interlock Protection (Limit by door open) Interlock LED Lighting / Power Power Power Power Power Prevention |
Output voltage / output current with the front panel "Output Monitor" |
Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) |
High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual |
External output control BOX |
|
ALR403- □ |
Available upon quote |
0.1kv ~ 40kv |
D-Sub connector: 0 to 40kv → 0-10V |
D-Sub connector: 0 to 250μA → 0-10V |
250μA MAX |
5ppm or less (200mvp-P) @40kv/100μA |
Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) |
± 0.1%or less (5kv to 40kv) |
10ppm/h or less |
10ppm/℃ or less |
Within 20 ppm for fluctuation of AC input voltage ± 10% |
50 ppm or less @ fluctuations in total load at maximum output voltage |
10 -rotation potenthameter (coarse) & (Fine (fine tone)) |
BNC terminal: 0-10V → 0 to 40kv |
Over -voltage: 44kV, overcurrent protection: 275 μA |
Single -phase 100VAC ± 10% 50/60Hz |
Continent voltage control |
Freback Pushpur method + soft switching + soft start |
Freback Trans + Symmetric Cock Croft / Walton Circuit |
482W x 88H x 452D |
Front panel COARSE (rough tone) and FINE (fine tone) |
External control voltage 0VDC ~+10VDC, or external output control BOX (optional) |
Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting |
Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage |
Output voltage / output current with the front panel "Output Monitor" |
Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) |
High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual |
External output control BOX |
|
ALR303- □ |
Available upon quote |
0.1kv ~ 30kv |
D-Sub connector: 0 to 30kV → 0-10V |
D-Sub connector: 0 to 250μA → 0-10V |
250μA MAX |
Less than 5 ppm (150mVP-P) @30kv/100 μA |
Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) |
± 0.1%or less (5kv to 30kV) |
10ppm/h or less |
10ppm/℃ or less |
Within 50 ppm for fluctuation of AC input voltage ± 10% |
± 0.01%or less @ fluctuations in total load at maximum output voltage |
10 -rotation potenthameter (coarse) & (Fine (fine tone)) |
BNC terminal: 0-10V → 0 to 30kv |
Over -voltage: 33kV, overcurrent protection: 275 μA |
Single -phase 100VAC ± 10% 50/60Hz |
Continent voltage control |
Freback Pushpur method + soft switching + soft start |
Freback Trans + Symmetric Cock Croft / Walton Circuit |
482W x 88H x 452D |
Front panel COARSE (rough tone) and FINE (fine tone) |
External control voltage 0VDC ~+10VDC, or external output control BOX (optional) |
Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting |
Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage |
Output voltage / output current with the front panel "Output Monitor" |
Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) |
High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual |
External output control BOX |
Click on the part number for more information about each product