Ultra -low ripple noise, high -stability fixed voltage power supply ALR series-ALR503- □
Ultra -low ripple noise, high -stability fixed voltage power supply ALR series-FUTEX co., ltd.

Ultra -low ripple noise, high -stability fixed voltage power supply ALR series
FUTEX co., ltd.


About This Product

■ Characteristics

・ It is the optimal specification for research and development of charging particles such as electronic source, ion source, and electrostatic lenses that require high accuracy and initial experiments. ・ Manual operation by simple multi -dial. ・ The ripple monitor terminal is standard equipment, and it is possible to check the ripple of the power supply itself and the radio waveform on the high -pressure output side (load side). * ALR503 (50kV), ALR403 (40kV), ALR303 (30kV), each + / -total 6 series lineup

  • Product

    Ultra -low ripple noise, high -stability fixed voltage power supply ALR series

Share this product


350+ people viewing

Last viewed: 20 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of Ultra -low ripple noise, high -stability fixed voltage power supply ALR series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Output voltage Output voltage monitor Output current monitor Rated output current Ripple noise Ripple voltage monitor Voltage monitor accuracy DC stability Temperature coefficient Input fluctuation rate Load variable rate Output setting External input Protection circuit Input voltage control method Switching method Boosting system Outer diameter dimensions Output voltage control manual Output voltage control remote Protection function ① Protection function ➁ Output display usage environment accessories option
Ultra -low ripple noise, high -stability fixed voltage power supply ALR series-Part Number-ALR503- □

ALR503- □

Available upon quote

0.1kv ~ 50kv

D-Sub connector: 0 to 50kv → 0-10V

D-Sub connector: 0 to 250μA → 0-10V

250μA MAX

Less than 5 ppm (250mVP-P) @50kv/100 μA

Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz)

± 0.1%or less (5kv to 50kV)

10ppm/h or less

10ppm/℃ or less

Within 20 ppm for fluctuation of AC input voltage ± 10%

50 ppm or less @ fluctuations in total load at maximum output voltage

10 -rotation potenthameter (coarse) & (Fine (fine tone))

BNC terminal: 0-10V → 0 to 50kv

Over -voltage: 55kV, overcurrent protection: 275 μA

Single -phase 100VAC ± 10% 50/60Hz

Continent voltage control

Freback Pushpur method + soft switching + soft start

Freback Trans + Symmetric Cock Croft / Walton Circuit

482W x 88H x 452D

Front panel COARSE (rough tone) and FINE (fine tone)

External control voltage 0VDC ~+10VDC, or external output control BOX (optional)

Over -voltage protection (110%rated) Over Volt. LED lighting / overcurrent protection (110%rated) Over Current. LED lighting

Interlock Protection (Limit by door open) Interlock LED Lighting / Power Power Power Power Power Prevention

Output voltage / output current with the front panel "Output Monitor"

Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation)

High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual

External output control BOX

Ultra -low ripple noise, high -stability fixed voltage power supply ALR series-Part Number-ALR403- □

ALR403- □

Available upon quote

0.1kv ~ 40kv

D-Sub connector: 0 to 40kv → 0-10V

D-Sub connector: 0 to 250μA → 0-10V

250μA MAX

5ppm or less (200mvp-P) @40kv/100μA

Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz)

± 0.1%or less (5kv to 40kv)

10ppm/h or less

10ppm/℃ or less

Within 20 ppm for fluctuation of AC input voltage ± 10%

50 ppm or less @ fluctuations in total load at maximum output voltage

10 -rotation potenthameter (coarse) & (Fine (fine tone))

BNC terminal: 0-10V → 0 to 40kv

Over -voltage: 44kV, overcurrent protection: 275 μA

Single -phase 100VAC ± 10% 50/60Hz

Continent voltage control

Freback Pushpur method + soft switching + soft start

Freback Trans + Symmetric Cock Croft / Walton Circuit

482W x 88H x 452D

Front panel COARSE (rough tone) and FINE (fine tone)

External control voltage 0VDC ~+10VDC, or external output control BOX (optional)

Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting

Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage

Output voltage / output current with the front panel "Output Monitor"

Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation)

High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual

External output control BOX

Ultra -low ripple noise, high -stability fixed voltage power supply ALR series-Part Number-ALR303- □

ALR303- □

Available upon quote

0.1kv ~ 30kv

D-Sub connector: 0 to 30kV → 0-10V

D-Sub connector: 0 to 250μA → 0-10V

250μA MAX

Less than 5 ppm (150mVP-P) @30kv/100 μA

Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz)

± 0.1%or less (5kv to 30kV)

10ppm/h or less

10ppm/℃ or less

Within 50 ppm for fluctuation of AC input voltage ± 10%

± 0.01%or less @ fluctuations in total load at maximum output voltage

10 -rotation potenthameter (coarse) & (Fine (fine tone))

BNC terminal: 0-10V → 0 to 30kv

Over -voltage: 33kV, overcurrent protection: 275 μA

Single -phase 100VAC ± 10% 50/60Hz

Continent voltage control

Freback Pushpur method + soft switching + soft start

Freback Trans + Symmetric Cock Croft / Walton Circuit

482W x 88H x 452D

Front panel COARSE (rough tone) and FINE (fine tone)

External control voltage 0VDC ~+10VDC, or external output control BOX (optional)

Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting

Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage

Output voltage / output current with the front panel "Output Monitor"

Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation)

High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual

External output control BOX

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Voltage Generators Products

Other products of FUTEX co., ltd.

Reviews shown here are reviews of companies.


View more products of FUTEX co., ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree