Product
Ultra -low ripple noise, high -stability fixed voltage power supply ALR seriesHandling Company
FUTEX co., ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Boosting system | DC stability | External input | Input fluctuation rate | Input voltage | Load variable rate | Outer diameter dimensions | Output current monitor | Output display | Output setting | Output voltage | Output voltage control manual | Output voltage control remote | Output voltage monitor | Protection circuit | Protection function ① | Protection function ➁ | Rated output current | Ripple noise | Ripple voltage monitor | Switching method | Temperature coefficient | Voltage monitor accuracy | accessories | control method | option | usage environment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ALR503- □ |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | BNC terminal: 0-10V → 0 to 50kv | Within 20 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | 50 ppm or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | D-Sub connector: 0 to 250μA → 0-10V | Output voltage / output current with the front panel "Output Monitor" | 10 -rotation potenthameter (coarse) & (Fine (fine tone)) | 0.1kv ~ 50kv | Front panel COARSE (rough tone) and FINE (fine tone) | External control voltage 0VDC ~+10VDC, or external output control BOX (optional) | D-Sub connector: 0 to 50kv → 0-10V | Over -voltage: 55kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) Over Volt. LED lighting / overcurrent protection (110%rated) Over Current. LED lighting | Interlock Protection (Limit by door open) Interlock LED Lighting / Power Power Power Power Power Prevention | 250μA MAX | Less than 5 ppm (250mVP-P) @50kv/100 μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur method + soft switching + soft start | 10ppm/℃ or less | ± 0.1%or less (5kv to 50kV) | High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual | Continent voltage control | External output control BOX | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) | |
ALR403- □ |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | BNC terminal: 0-10V → 0 to 40kv | Within 20 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | 50 ppm or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | D-Sub connector: 0 to 250μA → 0-10V | Output voltage / output current with the front panel "Output Monitor" | 10 -rotation potenthameter (coarse) & (Fine (fine tone)) | 0.1kv ~ 40kv | Front panel COARSE (rough tone) and FINE (fine tone) | External control voltage 0VDC ~+10VDC, or external output control BOX (optional) | D-Sub connector: 0 to 40kv → 0-10V | Over -voltage: 44kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting | Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage | 250μA MAX | 5ppm or less (200mvp-P) @40kv/100μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur method + soft switching + soft start | 10ppm/℃ or less | ± 0.1%or less (5kv to 40kv) | High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual | Continent voltage control | External output control BOX | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) | |
ALR303- □ |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | BNC terminal: 0-10V → 0 to 30kv | Within 50 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | ± 0.01%or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | D-Sub connector: 0 to 250μA → 0-10V | Output voltage / output current with the front panel "Output Monitor" | 10 -rotation potenthameter (coarse) & (Fine (fine tone)) | 0.1kv ~ 30kv | Front panel COARSE (rough tone) and FINE (fine tone) | External control voltage 0VDC ~+10VDC, or external output control BOX (optional) | D-Sub connector: 0 to 30kV → 0-10V | Over -voltage: 33kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting | Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage | 250μA MAX | Less than 5 ppm (150mVP-P) @30kv/100 μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur method + soft switching + soft start | 10ppm/℃ or less | ± 0.1%or less (5kv to 30kV) | High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual | Continent voltage control | External output control BOX | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) |