High -performance DC high -voltage power supply ultra -low ripple noise, high stability fixed voltage power supply FLR seriesHandling Company
FUTEX co., ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Boosting system | DC stability | External input | Input fluctuation rate | Input voltage | Load variable rate | Outer diameter dimensions | Output current monitor | Output display | Output setting | Output voltage | Output voltage control (local) | Output voltage control (remote) | Output voltage monitor | Protection circuit | Protection function ① | Protection function ➁ | Rated output current | Ripple noise | Ripple voltage monitor | Switching method | Temperature coefficient | Voltage monitor accuracy | accessories | control method | option | usage environment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLR503- □ |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | 0-10V → 0 to 50kv | Within 20 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | 50 ppm or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | 10V/maximum output current | Output current (selected i-moni on Select switch) in the front panel "I/v monitor", output voltage (selected V-MONI with SELECT switch) | Rotary encoder | 0.1kv ~ 50kv | By the front panel rotary encoder | External control voltage 0VDC ~+10VDC or RS-232C control | D-Sub connector: 0 to 50kv → 0-10V | Over -voltage: 55kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) over volt. LED lighting / overcurrent protection (rated 110%Limit) Over Curent. LED lighting | Interlock Protection (Limit by door open) Interlock LED Lighting / Power Power Power Power Power Prevention | 250μA MAX | ≦ 5ppm (250mVP-P) @50kv/100 μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur type + zero bolt switching | 10ppm/℃ or less | ≦ ± 0.1% (5kv to 50kV) | High -pressure cable 3m (RG11/U Customer terminal unprocessed), AC cable (2m) | Continent voltage control | LAN (LANTRONIX) | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) | |
FLR403- □ |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | 0-10V → 0 to 40kv | Within 20 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | 50 ppm or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | 10V/maximum output current | Output current (selected i-moni on Select switch) in the front panel "I/v monitor", output voltage (selected V-MONI with SELECT switch) | Rotary encoder | 0.1kv ~ 40kv | By the front panel rotary encoder | External control voltage 0VDC ~+10VDC or RS-232C control | D-Sub connector: 0 to 40kv → 0-10V | Over -voltage: 44kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) over volt. LED lighting / overcurrent protection (rated 110%Limit) Over Curent. LED lighting | Interlock Protection (Limit by door open) Interlock LED Lighting / Power Power Power Power Power Prevention | 250μA MAX | ≦ 5ppm (200mVP-P) @40kv/100 μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur type + zero bolt switching | 10ppm/℃ or less | ≦ ± 0.1% (5kv to 40kv) | High -pressure cable 3m (RG11/U Customer terminal unprocessed), AC cable (2m) | Continent voltage control | LAN (LANTRONIX) | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) | |
FLR303- □ |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | 0-10V → 0 to 30kv | Within 20 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | 50 ppm or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | 10V/maximum output current | Output current (selected i-moni on Select switch) in the front panel "I/v monitor", output voltage (selected V-MONI with SELECT switch) | Rotary encoder | 0.1kv ~ 30kv | By the front panel rotary encoder | External control voltage 0VDC ~+10VDC or RS-232C control | D-Sub connector: 0 to 30kV → 0-10V | Over -voltage: 33kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Curent. LED lighting | Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage | 250μA MAX | ≦ 5ppm (150mVP-P) @30kv/100 μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur type + zero bolt switching | 10ppm/℃ or less | ≦ ± 0.1% (5kv to 30kV) | High -pressure cable 3m (RG11/U Customer terminal unprocessed), AC cable (2m) | Continent voltage control | LAN (LANTRONIX) | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) |