Specified measuring instrument that can be used as a drainage flowmeter for transactions and certification Non-full electromagnetic flowmeter FGHandling Company
Aichi Watch Electric Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Detector mass | Detector Installation conditions Incline | Detector Material Electrode/Earth ring | Detector material body | Detector integration accuracy | Detector Measuring fluid temperature | Detector liquid pressure | Detector Hydraulic conditions | Detector structure | Detector Minimum flow rate (Qmin) | Detector Maximum unfilled flow rate (Qw) | Detector Maximum flow rate (Qmax) | Detector conductivity | Detector ambient temperature | Detector mounted at discharge end/mounted in the middle of the pipe | Detector diameter | Detector cable | Converter power supply | Converter alarm display | Converter alarm output | Converter integrated flow value (m3) | Converter Instantaneous flow rate value (m3/h) | Converter power consumption | Transducer structure | Converter Ambient temperature/humidity | Converter pulse output | Converter analog output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FG150B |
Available upon quote |
Approximately 20kg |
1~10‰ |
SUS316L・SUS304 |
Hard vinyl chloride resin |
・Flow rate range ±0.1%F.S./±0.15%F.S.: 0.2~2 |
0~+45℃ |
0.3MPa or less (at full water) |
Upstream is uniform flow (regular flow), downstream is jet flow, and waterfront current appears in the flume inside the main body. |
IP68 (Submersion conditions: 10 days a year at a depth of 10m or 1 month a year at a depth of 3m) |
0.2m3/h |
50m3/h |
200m3/h |
0.1~4.0mS/cm *If the conductivity is outside the range, accurate measurement will not be possible or measurement will not be possible. |
-10~+55℃ (Do not freeze) |
・Upstream piping: Straight pipe section 10D or more ・Gradient 1~10‰ |
150mm |
・One Φ12 dedicated two-way shielded cable |
100VAC±10% 50/60Hz |
・Backflow detection (optional) Instantaneous flow rate value -0.0 |
・Backflow detection (optional) Analog output 2mA DC fixed |
9,999,999.90 |
999.9 |
20W or less |
IP30 *If installing outdoors, please put it in an outdoor box etc. |
-5~+45℃/85%RH or less (no condensation) |
・Open drain pulse unit 0.1/1/10m3 (selection) |
4~20mADC Maximum load resistance 550Ω or less Instantaneous flow rate *Can be set in 1m3/h units |