Mass flow (MF) display SP-835Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Voltage output | Maximum possible voltage input width | Voltage input | Alarm output status determination time | Alarm signal output terminal | Alarm signal output method | Alarm signal output judgment | Alarm signal preset value/output setting width setting | Adjustment method | Measurement type | Measurement method | Output temperature characteristics | Output response time | Output resolution | Input temperature characteristics | Valve forced open/close output terminal | Valve forced open/close input terminal | Valve forced open/close input method | SV display setting selection | SV Settable display range | SV display | SV Decimal point display | PV display range | PV measurement accuracy | PV display | PV display sampling time | PV decimal point display | PV low cut function | PV scaling method | PV overflow display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP-835 |
Available upon quote |
DC 0 ~ 5V output, load resistance 1kΩ or more |
DC -1 ~ 7V |
DC 0~5V |
Output is performed if the output conditions are met continuously even after the set time. |
Output from terminal block 7-8 |
Photomos relay 1a contact output 1 point |
Set the set value (set arbitrarily) and output setting width (set in %), and if the displayed value deviates from the set threshold, judgment output will be made by comparison. |
Can be set arbitrarily by preset value/output setting width setting mode |
Can be adjusted in analog input/output adjustment mode |
Instant measurement (displays the input after scaling conversion) |
A/D conversion method |
±100ppm/℃ (0 ~ 50℃) |
Approximately 50ms (however, as the time until the output change reaches 90%) |
Approx. 1 / 13,000 (for DC 0~5V voltage output) |
±100ppm/℃ (0 ~ 50℃) |
D-sub (9P) Output from 1-4, 9-4 |
Input from terminal block 2-4 (closed), 3-4 (open) (terminal 4 is COM) |
Accepts NPN open collector input or contact input (functions when ON for 50ms or more) |
Setting by flow value" or "Setting by percentage (%)" up to the flow rate display value at 5V can be selected by mode setting. |
When flow rate value display is selected: Up to the set flow rate display value at 5V can be displayed. |
LED green 4 digits |
When flow rate value display is selected: Linked to decimal point position on PV display |
-20% F.S.≦Mass flow output signal≦+140% F.S." |
±0.2%F.S.±1digit (23℃±5℃) for analog input |
LED red 4 digits |
Averages the display in 0.5 to 20 seconds (selectable in mode settings) |
Depending on the mode setting, it can be set from 0 to 0.000 after the decimal point. |
Can be set arbitrarily from 0 to 29% of maximum analog input (F.S value) |
Display value at maximum analog input (flow rate at 5V) can be set arbitrarily (0.001 ~ 9,999) |
Flashing when displaying “-999” or “9,999” (Decimal point position depends on mode setting) |