Recommended for power supply in radio dark rooms. It is a middle to large -capacity disorder wave blocking transformer "Noise Cut Trans ™ ️" with enhanced noise blocking characteristics. By adopting a different axial core structure in the coil -placed format, the noise of a wide range of bandwidth, from several kHz to the GHz band, is reliably blocked. It is recommended for power sources in places that are not allowed to have a slight noise, such as a laboratory of advanced science and radio waves. ■ Characteristics ・ It is a product that achieves a higher frequency bandwidth by enhancing the noise blocking characteristics. ・ By installing it on the power supply of the device, it prevents the entry and leakage of high frequency noise. ・ By using it for power supply in the radio room, the noise from entering from the power supply line can ensure that an environment without noise can be realized. -There are high noise blocking performance to prevent damage from induced lightning surge up to 5000V. ・ Since the ground loop can be cut by the triple shielding structure, the defect due to radiant noise is improved. ・ It can be used in various ground environment. ・ You can reduce other noise prevention elements. ・ It has a structure that is less likely to be affected by radiant noise. ・ Stud terminal connection is both on both the primary and secondary side. ・ In addition to standard products, custom -made specifications by ordering can be produced. ■ Ideal for the following applications. ・ When you want to take noise measures for medium to large equipment ・ When you want to take measures against high frequency noise ・ When the ground loop is formed and affected by radiation noise ・ When there is a limit on the ground method ・ When you want to take noise measures for advanced science research equipment

  • Product

    Disability wave blocking transformer noise cut transformer NCT-G (1kVA ~)




*Please note that we may not be able to accommodate sample requests.

1 Models of Disability wave blocking transformer noise cut transformer NCT-G (1kVA ~)

Product Image Part Number Price (excluding tax) Exchange -powered voltage Impulse -resistant voltage Insulation resistance Noise blocking characteristics Operation peripheral temperature Operation surroundings Phase Primary voltage fluctuation tolerance range Rated frequency Rated output capacity Rated voltage
Disability wave blocking transformer noise cut transformer NCT-G (1kVA ~)-Part Number-NCT-G (1KVA ~)

NCT-G (1KVA ~)

Available upon quote * The test voltage is 50 / 60Hz 1 minute due to rated voltage (between primary and 2nd winding, primary wires-grounding section, secondary volume-grounding) 1.2 / 50 μs standard shock wave (primary winding-2nd winding line, primary winding-contact section, secondary wiring-contact section) 100mΩ or more (DC1000V1 second winding-2nd winding line, primary winding-contact section, secondary volume-grounding) Differential mode (normal mode) 50kHz-100MHz -30db or less to 100MHz to 100MHz -30db or less. -10 ° C to 40 ℃ Relative humidity 95%or less (without condensation) Single phase and three phases 0.1 50 / 60Hz 1KVA ~ 200kva 100V primary voltage 100V -6600V, secondary voltage 100V -6600V