Disability wave blocking transformer noise cut transformer NCT-G (~ 500VA)-NCT-G (~ 500va)
Disability wave blocking transformer noise cut transformer NCT-G (~ 500VA)-Denken Seiki Research Institute

Disability wave blocking transformer noise cut transformer NCT-G (~ 500VA)
Denken Seiki Research Institute


About This Product

It has been well received by state -of -the -art research institutions, including nuclear physics. It is a noise cut -off transformer "noise cut transformer ️" that has enhanced noise blocking characteristics. By adopting a different axial core structure in the coil -placed format, the noise of a wide range of bandwidth, from several kHz to the GHz band, is reliably blocked. Since it can be expected to be more effective compared to products of other models, it has been adopted by advanced science research institutions, including nuclear physics. ■ Characteristics ・ It is a product that achieves a higher frequency bandwidth by enhancing the noise blocking characteristics. ・ By installing it on the power supply of the device, it prevents the entry and leakage of high frequency noise. -There are high noise blocking performance to prevent damage from induced lightning surge up to 5000V. ・ Since the ground loop can be cut by the triple shielding structure, the defect due to radiation noise is improved. ・ It can be used in various ground environment. ・ You can reduce other noise prevention elements. ・ It has a structure that is less likely to be affected by radiant noise. ・ The lead line connection is both the primary and secondary side. ・ In addition to standard products, custom -made specifications by ordering can be produced. ■ Ideal for the following applications. ・ When you want to use it in the device ・ When you want to take measures against small equipment noise ・ When you want to take measures against high frequency noise ・ When the ground loop is formed and affected by radiation noise ・ When there is a limit on the ground method ・ When you want to take noise measures for advanced science research equipment

  • Product

    Disability wave blocking transformer noise cut transformer NCT-G (~ 500VA)




*Please note that we may not be able to accommodate sample requests.

1 Models of Disability wave blocking transformer noise cut transformer NCT-G (~ 500VA)

Product Image Part Number Price (excluding tax) Exchange -powered voltage Impulse -resistant voltage Insulation resistance Noise blocking characteristics Operation peripheral temperature Operation surroundings Phase Primary voltage fluctuation tolerance range Rated frequency Rated output capacity Rated voltage
Disability wave blocking transformer noise cut transformer NCT-G (~ 500VA)-Part Number-NCT-G (~ 500va)

NCT-G (~ 500va)

Available upon quote 2000V50 / 60Hz 1 minute (between primary winding-2nd winding, primary wires-contact section, secondary winding-grounding) 1.2 / 50 μs standard shock wave 5kV (primary winding-2nd winding line, primary wires-contact section, secondary wires-contact section) 100mΩ or more (DC1000V1 second winding-2nd winding line, primary winding-contact section, secondary volume-grounding) Differential mode (normal mode) 50kHz-100MHz -40db or less to 100MHz to 100MHz -40db or less. -10 ° C to 40 ℃ Relative humidity 95%or less (without condensation) Single-phase 0.1 50 / 60Hz 50VA, 100VA, 300VA, 500VA ・ 100V primary voltage, 100V secondary voltage ・ 100V primary voltage, 2st voltage 200V ・ T primary voltage 200V, secondary voltage 100V