CO2 sensor / controller Marvel NMA -PR series (standard size)-Sea Hichi Sea System Co., Ltd.

NMA-PR-RD | CO2 sensor / controller Marvel NMA -PR series (standard size)
Sea Hichi Sea System Co., Ltd.


Price (excluding tax)

$416.00


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

CO2 Atm dependence

CO2 Temperature dependence

CO2 measurement method

CO2 warm -up

Co2 response time

Correction (calibration) function

LCD display

LED display

Measurement interval

Measurement range

Product warranty period

Relay output

Relay setting range CO2

Sensor predictive life

accuracy

alarm

power consumption

power supply

size

terms of use

type

weight

Data recording

See all 2 models in list
  • Part Number

    NMA-PR-RD




*Please note that we may not be able to accommodate sample requests.

CO2 sensor / controller Marvel NMA -PR series (standard size) NMA-PR-RD's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) CO2 Atm dependence CO2 Temperature dependence CO2 measurement method CO2 warm -up Co2 response time Correction (calibration) function Data recording LCD display LED display Measurement interval Measurement range Product warranty period Relay output Relay setting range CO2 Sensor predictive life accuracy alarm power consumption power supply size terms of use type weight
CO2 sensor / controller Marvel NMA -PR series (standard size)-Part Number-NMA-PR-RD $ 416.00 With 0.13% advanced adjustment function permmHg (0m in factory shipment) Great numbers of ± 0.2%or ± 2 ppm per 1 ° C (25 ° C standard) Optical type NDIR (non -scattered infrared absorption method) dual beam sensor Within 60 seconds 2 minutes or less (90%) Manual correction (calibration) CO2 concentration, temperature, and humidity are recorded on microSD card (attached) every 5 seconds. About 2 years in 1GB All display/CO2 concentration only display/hide selection (3 screen switching possible) 3 color switching lit by CO2 concentration (hidden selection can be selected) 5 seconds (Updata Period) ・ CO2: 0 ~ 3,000ppm ・ Temperature: 0 to 50 ℃ ・ Humidity: 20 to 90% One year Max 2a (30VDC or 250vac). 1) If it exceeds the contact and the normal open AL2, it is ON, and if it falls below AL1, it is OFF (reverse setting is also possible). ・ ALARM1: 100-2,980PPM ・ ALARM2: 120 ~ 3,000ppm About 10 years CO2: Within a large number of ± 75ppm or ± 5%(0ppm ~ 3,000 ppm) ・ ALARM1 or higher 4 times ・ ALARM2 or higher sounds 8 times ・ MUTE has a function Approximately 1.5W AC100 ~ 240V W120 x H120 x D28mm ・ Temperature: 0 to 50 ℃ ・ Humidity: 95%or less dew condensation (an environment with an airflow of 0.1m/s or more is recommended) Built -in data logger. Record CO2 concentration, temperature and humidity. 220

There are 2 models for this product.

Customers who viewed this product also viewed

Other products of Sea Hichi Sea System Co., Ltd.


View more products of Sea Hichi Sea System Co., Ltd.

About Company Handling This Product

Sea Hichi Sea System Co., Ltd.

  • Japan
  • Since 1979
  • 50 employees

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree