All Categories
History
Price (excluding tax)
・ Input number: 2 points ・ Input: fluorescent dissolved oxygen detector ・ Power supply voltage: 100-240 V AC (standard) ・ Options: Open collector output 4 points
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Ambient temperature
Conformity standard
Data update cycle
Instruction accuracy
Measurement range (rated scale) Dolut oxygen concentration
Measurement range (rated scale) Dolut oxygen saturation rate
Measurement range (rated scale) oxygen partial pressure
Measurement range (rated scale) temperature
Peripheral humidity
Protective structure
Self -diagnostic function
Serial communication
Serial communication and communication protocol
Serial communication cable length
Serial communication communication line
Serial communication communication method
Serial communication communication speed
Serial communication data bit/Parity
Serial communication error correction
Serial communication error detection
Serial communication format
Serial communication stop bit
Serial communication synchronous method
Time accuracy
Transmission output 1, 2-1
Transmission output 1, 2-2
Transmission output 1, 2-3
input
power supply
structure
Part Number
WIL-102-DO, EVTHandling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry UseImage | Price (excluding tax) | Ambient temperature | Conformity standard | Data update cycle | Instruction accuracy | Measurement range (rated scale) Dolut oxygen concentration | Measurement range (rated scale) Dolut oxygen saturation rate | Measurement range (rated scale) oxygen partial pressure | Measurement range (rated scale) temperature | Peripheral humidity | Protective structure | Self -diagnostic function | Serial communication | Serial communication and communication protocol | Serial communication cable length | Serial communication communication line | Serial communication communication method | Serial communication communication speed | Serial communication data bit/Parity | Serial communication error correction | Serial communication error detection | Serial communication format | Serial communication stop bit | Serial communication synchronous method | Time accuracy | Transmission output 1, 2-1 | Transmission output 1, 2-2 | Transmission output 1, 2-3 | input | power supply | structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 0 to 50 ℃ | ROHS command support | 5 seconds | Rely on the accuracy of the fluorescent dissolved oxygen detector | Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l | Scenery range: 0.0-200.0 %, decomposition ability: 0.1 % | Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa | Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃ | 35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | Perform the following operations from the external computer.・ Read and configure values and set -dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen arbitration, temperature reading / function change, adjustment / user storage area reading and setting. | Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | Half double communication | Select 9600, 19200, 38400 BPS by key operation | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Command resend | ・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) | ASCII, binary | Select 1 bit and 2 bits by key operation | Toning synchronization | Within ± 1%for the set time | Converts the dissolved oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen pressure or MV for each data update cycle, and output it in current. | If the transmission output maximum value and the lower limit of the transmission output are set to the same value, the transmission output is fixed to 4 ma DC. | ・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: Transmit output 1 span or transmission output within ± 0.3%of span | Fluorescent molten oxygen detector | 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC | ・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray panel: Membrane sheet |
Reviews shown here are reviews of companies.