・ Input number: 1 point ・ Input: Turbidity detection device (Optex Co., Ltd. muddy checker), SS detector (SS checker manufactured by Optex Co., Ltd.) ・ Power supply voltage: 24 V AC/DC ・ Options: Serial communication RS-485
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Ambient temperature
Conformity standard
Contact output
External dimensions
Input sampling cycle
Linearness
Moving average number
Peripheral humidity
Protective structure
Repetition
Self -diagnostic function
Serial Communication (Options: C5) Data Bit/Parity
Serial communication (Options: C5)
Serial communication (Options: C5) Certification format
Serial communication (Options: C5) Communication method
Serial communication (Options: C5) Communication protocol
Serial communication (Options: C5) Communication speed
Serial communication (Options: C5) Stop bit
Serial communication (Options: C5) Sync
Serial communication (Options: C5) error correction
Serial communication (option: C5) cable length
Serial communication (option: C5) communication line
Serial communication (option: C5) error detection
Time accuracy
Transmission output 1
Transmission output 2
mass
power supply
structure
Part Number
AER-101-TU1, C5Handling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry UseImage | Price (excluding tax) | Ambient temperature | Conformity standard | Contact output | External dimensions | Input sampling cycle | Linearness | Moving average number | Peripheral humidity | Protective structure | Repetition | Self -diagnostic function | Serial Communication (Options: C5) Data Bit/Parity | Serial communication (Options: C5) | Serial communication (Options: C5) Certification format | Serial communication (Options: C5) Communication method | Serial communication (Options: C5) Communication protocol | Serial communication (Options: C5) Communication speed | Serial communication (Options: C5) Stop bit | Serial communication (Options: C5) Sync | Serial communication (Options: C5) error correction | Serial communication (option: C5) cable length | Serial communication (option: C5) communication line | Serial communication (option: C5) error detection | Time accuracy | Transmission output 1 | Transmission output 2 | mass | power supply | structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | 0 to 50 ℃ | ROHS command support | ・ Relay contact 1A ・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4) ・ Electrical life: 100,000 times ・ Control operation: P operation, ON/OFF operation | W48XH96XD110mm case depth: 98.5mm (at panel mount) | 500ms | ± 0.2%± 1 digit of the measurement range span (however, no sensor accuracy is included) | 1 to 120 times | 35 ~ 85%RH (but not condensation) | Over-pressure category Ⅱ, pollution 2 (IEC61010-1) | ± 0.2%± 1 digit of the measurement range span (however, no sensor accuracy is included) | Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. | 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation | Perform the following operations from the external computer. ・ Read and set various set values ・ Calculation/SS input value, state reading ・ Change and adjust function ・ Reading and setting of user storage area | ASCII, binary | Half double communication | Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation | Select 9,600, 19,200, 38,400 BPS by key operation | Select 1 bit and 2 bits by key operation | Toning synchronization | Command resend | 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) | EIA RS-485 compliant | ・ Parity check, checksum (Shinko standard) ・ LRC (Modbus ASCII), CRC-16 (Modbus RTU) | Within ± 1%for the set time | ・ Convert the turbidity/SS input value and MV to the analog amount for each input sampling, and output it by current. ・ If the transmission output maximum value and the transmission output lower limit are set to the same value, the transmission output is fixed to 4 ma DC. | ・ The transmission output volume can be displayed. ・ Resolution: 12,000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span | Approximately 280g | 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC | ・ Control board embedded method (compatible panel thickness 1 ~ 8mm) ・ Case: flame -retardant resin color: black ・ Panel: Membrane sheet ・ Drip -proof / dustproof structure: front IP66 |