・ Control operation: PID ・ Event output: Select alarm operation by key operation ・ Control output OUT1: Non -contact voltage (for SSR drive) 12V DC ± 15% ・ Input: Multi -range ・ Power supply voltage: 100-240V AC (standard) ・ Options: Event input, heater disconnection warning (single phase)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Input DC current
Input DC voltage 1
Input DC voltage 2
Input measurement temperature resistor
Input thermoelectric dating
Measurement range scale -10 ~ 10mv input (decomposition ability 1)
Measurement range scale 0 ~ 100mv input (decomposition ability 1)
Measurement range scale 0 ~ 10V input (resolution 1)
Measurement range scale 0 ~ 10mv input (resolution 1)
Measurement range scale 0 ~ 1V input (resolution 1)
Measurement range scale 0 ~ 20mA input (resolution 1)
Measurement range scale 0 ~ 50mv input (resolution 1)
Measurement range scale 0 ~ 5V input (resolution 1)
Measurement range scale 1 ~ 5V input (decomposition ability 1)
Measurement range scale 4 ~ 20mA input (resolution 1)
Measurement range scale C input (decomposition ability 1 ° C/° f)
Measurement range scale E input (decomposed ability 1 ° C/° f)
Measurement range scale Input (decomposition ability 1 ° C/° f)
Measurement range scale N input (decomposed ability 1 ° C/° f)
Measurement range scale range B input (decomposed ability 1 ° C/° f)
Measurement range scale range J input (decomposed ability 1 ° C/° f)
Measurement range scale range JPT100 input (decomposition No ability 0.1 ° C/° f)
Measurement range scale range JPT100 input (decomposition ability 1 ° C/° f)
Measurement range scale range K input (decomposed ability 1 ℃/° f)
Measurement range scale range K input (decomposition No ℃/° f)
Measurement range scale range PL-II input (decomposed ability 1 ° C/° f)
Measurement range scale range PT100 input (decomposed ability 1 ℃/° f)
Measurement range scale range PT100 input (decomposition No ℃/° f)
Measurement range scale range R input (decomposition ability 1 ° C/° f)
Measurement range scale range T input (decomposition No ℃/° f)
Part Number
ACD-13A-S/M, EI, WHandling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Plastic & Rubber Manufacturing / Food Industry Use / Electronics & Electrical UseImage | Price (excluding tax) | Input DC current | Input DC voltage 1 | Input DC voltage 2 | Input measurement temperature resistor | Input thermoelectric dating | Measurement range scale -10 ~ 10mv input (decomposition ability 1) | Measurement range scale 0 ~ 100mv input (decomposition ability 1) | Measurement range scale 0 ~ 10V input (resolution 1) | Measurement range scale 0 ~ 10mv input (resolution 1) | Measurement range scale 0 ~ 1V input (resolution 1) | Measurement range scale 0 ~ 20mA input (resolution 1) | Measurement range scale 0 ~ 50mv input (resolution 1) | Measurement range scale 0 ~ 5V input (resolution 1) | Measurement range scale 1 ~ 5V input (decomposition ability 1) | Measurement range scale 4 ~ 20mA input (resolution 1) | Measurement range scale C input (decomposition ability 1 ° C/° f) | Measurement range scale E input (decomposed ability 1 ° C/° f) | Measurement range scale Input (decomposition ability 1 ° C/° f) | Measurement range scale N input (decomposed ability 1 ° C/° f) | Measurement range scale range B input (decomposed ability 1 ° C/° f) | Measurement range scale range J input (decomposed ability 1 ° C/° f) | Measurement range scale range JPT100 input (decomposition No ability 0.1 ° C/° f) | Measurement range scale range JPT100 input (decomposition ability 1 ° C/° f) | Measurement range scale range K input (decomposed ability 1 ℃/° f) | Measurement range scale range K input (decomposition No ℃/° f) | Measurement range scale range PL-II input (decomposed ability 1 ° C/° f) | Measurement range scale range PT100 input (decomposed ability 1 ℃/° f) | Measurement range scale range PT100 input (decomposition No ℃/° f) | Measurement range scale range R input (decomposition ability 1 ° C/° f) | Measurement range scale range T input (decomposition No ℃/° f) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | ・ 0 ~ 20mA DC, 4 ~ 20ma DC ・ Input impedance 50Ω, allowable input current 50mA or less | ・ 0 ~ 10mv DC, -10 ~ 10mv DC, 0 ~ 50mv DC, 0 ~ 100mv DC, 0 ~ 1V DC ・ Input impedance 1mΩ or more, allowed input voltage 5V DC or less, allowable signal source resistance 2kΩ or less | ・ 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC ・ Input impedance 100kΩ or more, allowed input voltage 15V DC or less, allowable signal source resistance of 100Ω or less | ・ PT100, JPT100 3 conductor type ・ Removable value per tolerable resistance value 10Ω or less per line | ・ K, J, R, S, B, E, T, N, PL-II, C (W/Re5-26) ・ External resistance 100Ω | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | -2000 ~ 10000 | 0 ~ 2315 ° C/32 ~ 4199 ° F | -200 ~ 800 ° C/-328 ~ 1472 ° F | 0 ~ 1760 ° C/32 ~ 3200 ° F | -200 ~ 1300 ° C/-328 ~ 2372 ° F | 0 ~ 1820 ° C/32 ~ 3308 ° F | -200 ~ 1000 ° C/-328 ~ 1832 ° F | -200.0 ~ 500.0 ° C/-328.0 ~ 932.0 ° F | -200 ~ 500 ° C/-328 ~ 932 ° F | -200 ~ 1370 ° C/-328 ~ 2498 ° F | -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F | 0 ~ 1390 ° C/32 ~ 2534 ° F | -200 ~ 850 ° C/-328 ~ 1562 ° F | ・ -200.0 ~ 850.0 ° C/-328.0 ~ 1562.0 ° F ・ -100.0 ° C/-148.0 ° C | 0 ~ 1760 ° C/32 ~ 3200 ° F | -200.0 ~ 400.0 ° C/-328.0 ~ 752.0 ° F |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.