All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
20.2hours
Relatively Fast Response
* Please specify p ( +) or n ( -) for □. ■ Specifications Overview ・ High accuracy / high stability ・ Output voltage: 40kV ・ Output power: 10W ・ Continuous output short circuit protection circuit ・ With output voltage / current monitor ・ Low ripple = 5PPM (200mvp-p@40kv or less) ・ Stability is 10ppm/1H or less ・ The temperature coefficient is 10 ppm/℃ or less
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Boosting system
DC stability
External input
Input fluctuation rate
Input voltage
Load variable rate
Outer diameter dimensions
Output current monitor
Output display
Output setting
Output voltage
Output voltage control manual
Output voltage control remote
Output voltage monitor
Protection circuit
Protection function ①
Protection function ➁
Rated output current
Ripple noise
Ripple voltage monitor
Switching method
Temperature coefficient
Voltage monitor accuracy
accessories
control method
option
usage environment
Part Number
ALR403- □Handling Company
FUTEX co., ltd.Categories
Image | Price (excluding tax) | Boosting system | DC stability | External input | Input fluctuation rate | Input voltage | Load variable rate | Outer diameter dimensions | Output current monitor | Output display | Output setting | Output voltage | Output voltage control manual | Output voltage control remote | Output voltage monitor | Protection circuit | Protection function ① | Protection function ➁ | Rated output current | Ripple noise | Ripple voltage monitor | Switching method | Temperature coefficient | Voltage monitor accuracy | accessories | control method | option | usage environment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Freback Trans + Symmetric Cock Croft / Walton Circuit | 10ppm/h or less | BNC terminal: 0-10V → 0 to 40kv | Within 20 ppm for fluctuation of AC input voltage ± 10% | Single -phase 100VAC ± 10% 50/60Hz | 50 ppm or less @ fluctuations in total load at maximum output voltage | 482W x 88H x 452D | D-Sub connector: 0 to 250μA → 0-10V | Output voltage / output current with the front panel "Output Monitor" | 10 -rotation potenthameter (coarse) & (Fine (fine tone)) | 0.1kv ~ 40kv | Front panel COARSE (rough tone) and FINE (fine tone) | External control voltage 0VDC ~+10VDC, or external output control BOX (optional) | D-Sub connector: 0 to 40kv → 0-10V | Over -voltage: 44kV, overcurrent protection: 275 μA | Over -voltage protection (110%rated) Over Volt. LED lighting, overcurrent protection (110%rated) Over Current. LED lighting | Interlock protection (Limit with door open) Interlock LED lighting, high -pressure re -output prevention when power out of power outage | 250μA MAX | 5ppm or less (200mvp-P) @40kv/100μA | Monitor the discharge of the load side and high -speed fluctuations (20Hz to 2MHz) | Freback Pushpur method + soft switching + soft start | 10ppm/℃ or less | ± 0.1%or less (5kv to 40kv) | High -pressure cable 3m (RG11/U Open of customer side), AC cable (2m), 1 part of the instruction manual | Continent voltage control | External output control BOX | Installation location → Indoor temperature →+0 to 40 ° C humidity → 0%to 85%RH (without condensation) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
20.2hrs