Noise blocking exchange automatic constant voltage device noise cut AVR-Denken Seiki Research Institute

Single phase 50kva | Noise blocking exchange automatic constant voltage device noise cut AVR
Denken Seiki Research Institute


Price (excluding tax)

Estimate Required


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Exchange -powered voltage

Impulse -resistant voltage

Input frequency tolerance

Input voltage fluctuation tolerance range

Insulation resistance

Noise blocking characteristics

Operation peripheral temperature

Operation surroundings

Output current tolerance

Output frequency

Output voltage accuracy

Output voltage fine adjustment range

Output voltage strain distortion rate

Place to use

Power factor

Rated input frequency

Rated input voltage

Rated output capacity

Rated output voltage

Transitional response characteristics

efficiency

others

See all 5 models in list
  • Part Number

    Single phase 50kva




*Please note that we may not be able to accommodate sample requests.

Noise blocking exchange automatic constant voltage device noise cut AVR Single phase 50kva's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Exchange -powered voltage Impulse -resistant voltage Input frequency tolerance Input voltage fluctuation tolerance range Insulation resistance Noise blocking characteristics Operation peripheral temperature Operation surroundings Output current tolerance Output frequency Output voltage accuracy Output voltage fine adjustment range Output voltage strain distortion rate Place to use Power factor Rated input frequency Rated input voltage Rated output capacity Rated output voltage Transitional response characteristics efficiency others
Noise blocking exchange automatic constant voltage device noise cut AVR-Part Number-Single phase 50kva Available upon quote 1500V50 / 60Hz 1 minute (between circuit-housing, input-output) * Rated voltage 251V or more 2000V 1.2 / 50μs Standard shock wave 5kv1 times (JEC-0202 input and housing) ± 1Hz ± 10% (single -phase 510va to 10KVA ± 15%) 10mΩ or more (between DC1000V circuit-housing, input-output) Differential mode (normal mode) 10kHz ~ 100MHz -40db or less Common mode DC ~ 100MHz -40db or less. -10 ° C to 40 ℃ Relative humidity 10-90% (without condensation) 0 to 100% (at the load rate of 1.0), 0 to 70% (at 0.7 (delay)) Same for input ± 1% Approximately ± 2.5% 2%or less (rated input, full load) Corrosive gas, remarkable conductive dustless, breathable indoor atmosphere 0.94 or more (when rated input / full load) 50Hz dedicated or 60Hz only (specified when ordering) 100V to 440V (specified when ordering) Single phase 510va ~ 100kVA, three -phase 3kVA ~ 300kva (specified when ordering) 100V to 440V (specified when ordering) Within 0.3 seconds (time to set a sudden change of 10%input voltage within ± 1%) 80-93% (rated input / full resistance) Please contact us as you can also make specifications other than the above.

There are 5 models for this product.

Other products of Denken Seiki Research Institute


View more products of Denken Seiki Research Institute

About Company Handling This Product