All Categories
History
Product
Ideal for exhibiting and evaluating MFS02 Thermal mass flow sensor MFS amplification moduleHandling Company
OG Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Voltage range (heater) | Temperature sensor | Current consumption | Channel cross section | Dimensions (LxWxH in mm) | Installation | Control mode | Output signal range (flow rate) | Built-in sensor | Supply voltage | Usage measurement range | Heater power | Gain | Analog output load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IST_A05_Flow module mit MFS02 |
Available upon quote |
2VDC~5VDC |
Pt RTD Pt1000 (passive–output connected directly) |
<50mA |
2mm2 |
70x35x30 |
2xM3 screws |
Full bridge mode |
-1.8VDC~12VDC (non-linear), adjustable with potentiometer |
MFS02 |
12VDC external supply (no reverse polarity connection protection) |
≥0m/s~2m/s (0ml/min~240ml/min) |
Approximately 6.6mW at 2V heater voltage, 14.9mW at 3V heater voltage, approximately 26.4mW at 4V heater voltage, 41.3mW at 5V heater voltage |
23~10,000, adjusted with potentiometer |
RL≥25kΩ (output short circuit protection) |