Speed control type brushless motor driver TCP-S27AHandling Company
TSUKASA ELECTRIC CO.,LTDCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Current limit value (during home return operation) | Overload measurement current | Speed setting (rotation speed setting) | Speed variable range | Mass | Magnetic pole sensor | Compatible motor | External speed command coefficient | Control circuit power consumption | Signal output | Signal input | Protection function: power supply voltage drop | Protection function: overcurrent | Protection function: overload | Protection function: motor restraint | Protection function: fuse protection | Protection function: Sensor abnormality | Storage environment | Usage environment | Soft start setting | PWM frequency | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TCP-S27A-55N |
Available upon quote |
DC24V±10% or less |
3.3A |
620mA or more |
Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system |
L: 200~3,700rpm, M: 200~6,350rpm, N: 200~8,000rpm |
Approx. 30g (body only) |
Hall IC (square wave output) |
TG-55L, TG-55M, TG-55N |
1,800rpm/V±5% |
1W or less |
Rotation synchronization signal output, alarm output |
Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input |
Detects a drop in power supply voltage and cuts off the output (automatic recovery) |
Detects abnormal motor current and cuts off output (automatic recovery) |
If a current exceeding the rated output current flows continuously, the output is cut off (state maintained) and reset by turning the start input “open” and turning the power on again. |
Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 0.5 A or more when the speed command value is 250 rpm or more, determines the motor to be restrained, and starts input “open” And reset by turning on the power again |
Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) |
Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. |
-10~60℃, 85%RH or less (no condensation) |
0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) |
Approximately 20.0KHz |
Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 |
|
TCP-S27A-22D |
Available upon quote |
DC12V±10% or less |
2.2A |
570mA or more |
Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system |
200~4,900rpm |
Approx. 30g (body only) |
Hall IC (square wave output) |
TG-22D |
1,200rpm/V±5% |
1W or less |
Rotation synchronization signal output, alarm output |
Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input |
Detects a drop in power supply voltage and cuts off the output (automatic recovery) |
Detects abnormal motor current and cuts off output (automatic recovery) |
If a current exceeding the rated output current flows continuously, the output is cut off (state maintained) and reset by turning the start input “open” and turning the power on again. |
Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 0.2 A or more when the speed command value is 250 rpm or more, determines the motor to be restrained, and starts input “open” And reset by turning on the power again |
Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) |
Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. |
-10~60℃, 85%RH or less (no condensation) |
0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) |
Approximately 20.0KHz |
Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 |
|
TCP-S27A-22A |
Available upon quote |
DC24V±10% or less |
2.2A |
285mA or more |
Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system |
200~4,900rpm |
Approx. 30g (body only) |
Hall IC (square wave output) |
TG-22A |
1,200rpm/V±5% |
1W or less |
Rotation synchronization signal output, alarm output |
Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input |
Detects a drop in power supply voltage and cuts off the output (automatic recovery) |
Detects abnormal motor current and cuts off output (automatic recovery) |
If a current exceeding the rated output current flows continuously, the output is cut off (state maintained) and reset by turning the start input “open” and turning the power on again. |
Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 0.2 A or more when the speed command value is 250 rpm or more, determines the motor to be restrained, and starts input “open” And reset by turning on the power again |
Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) |
Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. |
-10~60℃, 85%RH or less (no condensation) |
0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) |
Approximately 20.0KHz |
Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 |
|
TCP-S27A-611B |
Available upon quote |
DC24V±10% or less |
2.2A |
360mA or more |
Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system |
200~6,900rpm |
Approx. 30g (body only) |
Hall IC (square wave output) |
TG-611B |
1,500rpm/V±5% |
1W or less |
Rotation synchronization signal output, alarm output |
Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input |
Detects a drop in power supply voltage and cuts off the output (automatic recovery) |
Detects abnormal motor current and cuts off output (automatic recovery) |
If a current exceeding the rated output current flows continuously, the output is cut off (state maintained) and reset by turning the start input “open” and turning the power on again. |
Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 0.2 A or more when the speed command value is 250 rpm or more, determines the motor to be restrained, and starts input “open” And reset by turning on the power again |
Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) |
Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. |
-10~60℃, 85%RH or less (no condensation) |
0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) |
Approximately 20.0KHz |
Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 |
|
TCP-S27A-609 |
Available upon quote |
DC24V±10% or less |
6.6A |
1,570mA or more |
Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system |
A: 100 ~ 3,700rpm, B・C: 100 ~ 3,800rpm |
Approx. 30g (body only) |
Hall element (analog voltage output) |
TG-609A, TG-609B, TG-609C |
1,000rpm/V ±5% |
1W or less |
Rotation synchronization signal output, alarm output |
Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input |
Detects a drop in power supply voltage and cuts off the output (automatic recovery) |
Detects abnormal motor current and cuts off output (automatic recovery) |
If a current exceeding the rated output current flows continuously, the output will be cut off (state maintained) and reset by turning the start input “open” and turning the power on again. |
Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 1A or more when the speed command value is 250rpm or more, determines the motor to be restrained, starts input "open" and , reset by turning the power on again |
Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) |
Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. |
-10~60℃, 85%RH or less (no condensation) |
0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) |
Approximately 20.0KHz |
Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 |
|
TCP-S27A-503 |
Available upon quote |
DC24V±10% or less |
6.6A |
A: 1,150mA or more, B: 1,790mA or more |
Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system |
A: 100~4,900rpm, B: 100~7,220rpm |
Approx. 30g (body only) |
Hall IC (rectangular wave output) |
TG-503A, TG-503B |
1,500rpm/V±5% |
1W or less |
Rotation synchronization signal output, alarm output |
Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input |
Detects a drop in power supply voltage and cuts off the output (automatic recovery) |
Detects abnormal motor current and cuts off output (automatic recovery) |
If a current exceeding the rated output current flows continuously, the output will be cut off (state maintained) and reset by turning the start input “open” and turning the power on again. |
Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 1A or more when the speed command value is 250rpm or more, determines the motor to be restrained, starts input "open" and , reset by turning the power on again |
Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) |
Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. |
-10~60℃, 85%RH or less (no condensation) |
0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) |
Approximately 20.0KHz |
Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 |