Image | Part Number | Price (excluding tax) | Power supply | Scanning speed (m/s) | Mass (kg) Total mass | Mass | Tolerance settings | Display interval | Display section | Target value setting | Measurement area front and back (mm) | Measurement area top and bottom (mm) | Measurement accuracy (μm) Repeatability | Measurement accuracy (μm) Linearity | Measurement accuracy (μm) Reproducibility | Measuring range (mm) | Number of measurements (/s) | Measured value display section | Measurement mode | Minimum display value (μm) | Number of connected sensors | Ambient temperature (℃) | Light source | Laser class | Data calculation processing | Data output | Alarm | Mass (kg) Light transmitter | Mass (kg) Installation stand | Mass (kg) Photodetector | Others |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LMG027 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
85 |
2 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7 |
Set separately for left and right measurement values |
0 |
2 |
±0.03 |
±0.3 |
±0.5 |
0.01~2 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0.01 |
1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
2 |
2 |
2 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMG127 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
226 |
2.5 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7 |
Set separately for left and right measurement values |
4 (2) |
12 |
±0.04 |
±0.5 |
±1 |
0.05~12 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0.01 |
1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
2.5 |
2.5 |
2.5 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMG307 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
355 |
2.7 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7 |
Set separately for left and right measurement values |
10 |
30 |
±0.10 |
±1 |
±2 |
0.2~30 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0 |
1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
2.7 |
2.7 |
2.7 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMG607 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
707 |
4.8 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7 |
Set separately for left and right measurement values |
30 |
60 |
±0.35 |
±2.5 |
±4 |
0.5~60 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0.1 |
1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
2.2 |
1.6 |
1 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMG807 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
990 |
9 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7 |
Set separately for left and right measurement values |
40 |
80 |
±0.6 |
±4 |
±5 |
0.5~80 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0.1 |
1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
4 |
3 |
2 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMG1507 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
1,130 |
16.5 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7 |
Set separately for left and right measurement values |
20 |
150 |
±2 |
±8 |
±12 |
0.7~150 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0.1 |
1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
7.5 |
4.5 |
4.5 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMGW2207 |
Available upon quote |
AC100~240V, 50/60Hz, 30VA |
990 |
33 |
4kg |
Set the upper and lower limits of the decimal point. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered |
D7-W |
Set separately for left and right measurement values |
40 |
220 |
±2 (±0.6) |
±12 (±4) |
±15 (±5) |
0.7~220 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
Select up to 2 outer diameter locations and 3 spacing locations |
0.1 |
1 unit (for LMGW2207) |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value, moving average value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
20 |
16.5 |
6 |
Measurement using external signals, calibration, offset of measured values, zero set |
|
LMG127XY |
Available upon quote |
AC85~264V, 50/60Hz, 30VA |
226 |
5 |
4kg |
Set the upper and lower limits of the decimal point for each left and right data calculation value. |
Arbitrarily set between 0.28ms and 4.4s: 5 types can be registered (moving average can also be set) |
D7-XY |
Set separately for left and right measurement values |
6 |
6 |
±0.05 |
±0.5 |
±0.5 |
0.1~12 |
3,600 |
Measured values from two locations can be displayed simultaneously on the left and right measured value display sections. |
In addition to 2 locations on the outer diameter and 3 locations on each of X and Y, outer diameter X-Y, average of outer diameters X and Y |
0.01 |
LMG127XY1 unit |
0~45 |
Visible semiconductor laser (wavelength: 655nm) |
CLASS2 (IEC/JIS) |
Average value, maximum value, minimum value, maximum value - minimum value |
RS-232C, analog ±10V (BCD is optional) |
When the error is within the tolerance range, the lamp on the display panel lights up and the alarm contact on the rear terminal block closes. |
- | - | - |
Measurement using external signals, calibration, offset of measured values, zero set |
Click on the part number for more information about each product