Resin pressure sensor CZ-100PHandling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Limit overload | Allowable overload pressure | Accuracy, linearity | Strain gauge maximum allowable temperature | Intrinsically safe explosion-proof | Recommended tightening | Impulse tube material | Impulse tube cover material | Pressure conversion method | Specification | Hysteresis | Diaphragm material | Diaphragm surface treatment | Diaphragm maximum allowable temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CZ-100P-HB-SN |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
150℃ |
Standard specification (for non-intrinsically safe explosion-proof) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
SUS630 (standard) |
No surface treatment (standard) |
400℃ |
|
CZ-100P-HB-SNG |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
150℃ |
Intrinsically safe explosion-proof type (for indoor use) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
SUS630 (standard) |
No surface treatment (standard) |
400℃ |
|
CZ-100P-HB-SNH |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
150℃ |
Intrinsically safe explosion-proof type (for outdoor use) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
SUS630 (standard) |
No surface treatment (standard) |
400℃ |
|
CZ-100P-HB-SK |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
150℃ |
Standard specification (for non-intrinsically safe explosion-proof) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
SUS630 (standard) |
Ceramic kanigen plating |
400℃ |
|
CZ-100P-HB-SKG |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
150℃ |
Intrinsically safe explosion-proof type (for indoor use) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
SUS630 (standard) |
Ceramic kanigen plating |
400℃ |
|
CZ-100P-HB-SKH |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
150℃ |
Intrinsically safe explosion-proof type (for outdoor use) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Types over 70MPa: ±2.0% of span) [When diaphragm temperature is 150°C] |
SUS630 (standard) |
Ceramic kanigen plating |
400℃ |
|
CZ-100P-HB-HN |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
150℃ |
Standard specification (for non-intrinsically safe explosion-proof) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
Hastelloy C |
No surface treatment (standard) |
400℃ |
|
CZ-100P-HB-HNG |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
150℃ |
Intrinsically safe explosion-proof type (for indoor use) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
Hastelloy C |
No surface treatment (standard) |
400℃ |
|
CZ-100P-HB-HNH |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
150℃ |
Intrinsically safe explosion-proof type (for outdoor use) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
Hastelloy C |
No surface treatment (standard) |
400℃ |
|
CZ-100P-HB-HK |
Available upon quote |
150% of span (2,000% of span for LLA type 0.5MPa, 1,000% of span for LLA type 1MPa) |
120% of span (LLA type 0.5MPa is 1,000% of span, LLA type 1MPa is 500% of span) |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
150℃ |
Standard specification (for non-intrinsically safe explosion-proof) |
30N・m |
SUS403 |
SUS304 |
4-sided adhesive strain gauge Wheatstone bridge |
General specification type |
±1.0% of span (Type over 50MPa: ±2.0% of span) |
Hastelloy C |
Ceramic kanigen plating |
400℃ |