Pilot Module Mass Flow Controller SMARTTRAK Series-C100L
Pilot Module Mass Flow Controller SMARTTRAK Series-C100L-HP
Pilot Module Mass Flow Controller SMARTTRAK Series-C50L
Pilot Module Mass Flow Controller SMARTTRAK Series-FCC

Pilot Module Mass Flow Controller SMARTTRAK Series
FCC


About This Product

A multi -gas multi -range that can be easily operated with a pilot module of full scale flow, measurement gas, output/setting signal. 10 types of measurement gases are input and can be easily changed with the pilot module. It can be used in a wide range of fields such as analysis, fuel cells, liquid crystal, organic EL, bio, culture, food, environmental measurement, burning gas control, factory equipment, and experimental equipment.

  • Product

    Pilot Module Mass Flow Controller SMARTTRAK Series

Share this product


510+ people viewing

Last viewed: 4 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

11 Models of Pilot Module Mass Flow Controller SMARTTRAK Series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Actuator method Bearing pressure Connecting joint Control flow rate range Driving power (MFC) Driving power supply (MFM) External leak Flow range range Flow rate accuracy Interviewed gas part material Pressure impact Reproducibility Setting/output signal Sticker material Temperature impact Used temperature range Valve type responsiveness
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100L

C100L

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 500ma 15-24VDC ± 10 % 30ma 5 × 10-10PA ・ M3/SECHE 10SCCM ~ 50SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485), ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100m

C100m

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 800ma 15-24VDC ± 10 % 230ma 5 × 10-10PA ・ M3/SECHE 20-200SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485), ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100m1

C100m1

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 1260ma 15-24VDC ± 10 % 230ma 5 × 10-10PA ・ M3/SECHE 201-300SLPM ± 2.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485), ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100H

C100H

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 1260ma 15-24VDC ± 10 % 230ma 5 × 10-10PA ・ M3/SECHE 100-500SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485), ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100H1

C100H1

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 1260ma 15-24VDC ± 10 % 230ma 5 × 10-10PA ・ M3/SECHE 501-800SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485), ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100H2

C100H2

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 1260ma 15-24VDC ± 10 % 230ma 5 × 10-10PA ・ M3/SECHE 801-1000SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485), ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C100L-HP

C100L-HP

Available upon quote Solenoid valve (not eligible for meters) 10.3MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 800ma - 5 × 10-10PA ・ M3/SECHE 10SCCM ~ 20SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485) ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C140

C140

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 800ma - 5 × 10-10PA ・ M3/SECHE 10SCCM ~ 200SLPM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485) ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C101

C101

Available upon quote Solenoid valve (not eligible for meters) 3.4MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 400ma 15-24VDC ± 10 % 130ma 5 × 10-10PA ・ M3/SECHE 4SCCM ± 1.0 % F.S SUS316L, Biton or Neophane or Calretz or Polyamide selection ± 0.0015 %/kpaf.s ± 0.2 % F.S Standards: 0-5VDC, 1-5VDC, 0 ~ 10VDC, 4-20mA, 0-20mA, RS232 Changes Options: RS485, DeviceNet, ModBusrtu (RS232, RS485) ProfibusDP (RS232), FieldBus (RS232) Biton or Neopen Select ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C50L

C50L

Available upon quote Solenoid valve (not eligible for meters) 1MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 315mars485: 130ma 15-24VDC ± 10 % 85ma 5 × 10-10PA ・ M3/SECHE 20SCCM ~ 50SLPM ± 1.0 % F.S SUS316LOR Aluminum Selection, Bitton ± 0.0015 %/kpaf.s ± 0.25 % F.S RS232OR0 ~ 5VDC+RS232OR4 ~ 20ma+RS232orRs485 Select Byton ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)
Pilot Module Mass Flow Controller SMARTTRAK Series-Part Number-C50m

C50m

Available upon quote Solenoid valve (not eligible for meters) 1MPa (g) 1/4SWL, 1/4VCO, 1/4VCR, 6mmswl, etc. 2-100 % F.S 24VDC ± 10 % 850mars485: 130ma - 5 × 10-10PA ・ M3/SECHE 50-200SLPM ± 1.0 % F.S SUS316LOR Aluminum Selection, Bitton ± 0.0015 %/kpaf.s ± 0.25 % F.S RS232OR0 ~ 5VDC+RS232OR4 ~ 20ma+RS232orRs485 Select Byton ± 0.05 %/℃ F.S 0 to 50 ℃ NC: Normal Close 2sec (within ± 2 % of the set value)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of FCC


View more products of FCC

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.