Diaphram type high -precision digital quantity pump smart digital seriesHandling Company
Grundfos Pumps CorporationItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 2 Relay Output | 2 relay output | Analog 0/4-20ma Control Input | Analog 0/4-20ma control input | Analog Control 0/4-20ma | Analog Input Scaling | Analog Signal Output 0/4-20ma | Analog control 0/4-20ma | Analog input scaling | Analog signal output 0/4-20ma | Auto Flow Adapt (Automatic Flow Rate Adjustment) | Auto flow adapt (automatic flow rate adjustment) | Automatic Air Removal While Waiting for a Pump | Automatic air removal while waiting for a pump | Batch Control (Pulse Base) | Batch control (pulse base) | Calibration mode | Control Variant | Control variant | Coon -down Ratio (Manual) | Coon -down ratio (manual) | DOUBLE DIAPHRAGM Leak Detection (Optional) | Digital Communication Control (Field Bus) | Digital Input/Output (Genibus) e-BOX Input/Output (PROFIBUSDP or ADDITIONALARM RELAY) | Digital communication control (field bus) | Digital input/Output (Genibus) e-BOX input/output (PROFIBUSDP or additional alarm relay) | Display | Double diaphragm leak detection (optional) | EXTERNAL STOP input | External stop input | Failure Diagnostic Function | Failure diagnostic function | Flow Rate Measurement | Flow rate measurement | Housing Standard | Housing standard | LIQUID VISCOSITY (Maximum) | Liquid viscosity (maximum) | Manual Operation Control | Manual operation control | Maximum Amount of Water (ℓ/h) | Maximum Power Consumption | Maximum amount of water (ℓ/h) | Maximum power consumption | Maximum pressure (MPA) | Maximum presure (MPA) | Pressure Monitoring | Pressure monitoring | Pulse Control (1: n) | Pulse Control (Set in Mℓ/Pulse) | Pulse Control Input | Pulse control (1: n) | Pulse control (set in Mℓ/pulse) | Pulse control input | Relay Setting: Alarm, Warning, Stroke Signal, PUMP Quantitative Injection | Relay Setting: Timer (Cycle), Timer (Week) | Relay setting: Alarm, warning, stroke signal, pump quantitative injection | Relay setting: Timer (cycle), timer (week) | Repeated Injection Accuracy | Repeated injection accuracy | Service Information Display | Service information display | Slow Mode (Cavitation Prevention) | Slow mode (cavitation prevention) | Sound Pressure Level (Maximum) | Sound pressure level (maximum) | Supply Voltage | Supply voltage | Tank Liquid Level Low -Level Signal Input | Tank Liquid Surface Empty Tank Signal Input | Tank liquid level low -level signal input | Tank liquid surface empty tank signal input | Timer (Cycle) | Timer (Week) | Timer (cycle) | Timer (week) | Weight (Maximum) | Weight (maximum) | display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
S series DDA S |
Available upon quote | EXISTENCE | Existence | EXISTENCE | Existence | EXISTENCE | EXISTENCE | EXISTENCE | Existence | Existence | Existence | Yes (FCM) | Yes (FCM) | EXISTENCE | Existence | EXISTENCE | Existence | EXISTENCE | FCM/AR | FCM/AR | 1000: 1 (7.5-16 IS 3000: 1) | 1000: 1 (7.5-16 is 3000: 1) | - | EXISTENCE | EXISTENCE | Existence | Existence | Graphic Display | - | EXISTENCE | Existence | Yes (FCM) | Yes (FCM) | Yes (FCM) | Yes (FCM) | IP65, NEMA4X | IP65, NEMA4X | 2500MPAS (CP) | 2500MPAS (CP) | EXISTENCE | Existence | 30 | 24W | 30 | 24W | 1.6 | 1.6 | Yes (FCM) | Yes (FCM) | - | EXISTENCE | EXISTENCE | - | Existence | Existence | EXISTENCE | EXISTENCE | Existence | Existence | 1% | 1% | EXISTENCE | Existence | EXISTENCE | Existence | 60db (a) | 60db (a) | AC Single Phase 100 ~ 240V50/60Hz | AC single phase 100 ~ 240V50/60Hz | EXISTENCE | EXISTENCE | Existence | Existence | EXISTENCE | EXISTENCE | Existence | Existence | 3.2kg | 3.2kg | Graphic display | |
S series DDC S |
Available upon quote | Yes (AR) | Yes (AR) | Yes (AR) | Yes (AR) | Yes (AR) | - | - | Yes (AR) | - | - | - | - | - | - | - | - | EXISTENCE | AR/A | AR/A | 1000: 1 (7.5-16 IS 3000: 1) | 1000: 1 (7.5-16 is 3000: 1) | - | - | - | - | - | Graphic Display | - | EXISTENCE | Existence | - | - | - | - | IP65, NEMA4X | IP65, NEMA4X | 2500MPAS (CP) | 2500MPAS (CP) | EXISTENCE | Existence | 15 | 22W | 15 | 22W | 1 | 1 | - | - | - | EXISTENCE | EXISTENCE | - | Existence | Existence | Yes (AR) | - | Yes (AR) | - | 1% | 1% | EXISTENCE | Existence | EXISTENCE | Existence | 60db (a) | 60db (a) | AC Single Phase 100 ~ 240V50/60Hz | AC single phase 100 ~ 240V50/60Hz | EXISTENCE | EXISTENCE | Existence | Existence | - | - | - | - | 3.2kg | 3.2kg | Graphic display | |
S series DDE S |
Available upon quote | Yes (PR) | Yes (PR) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | PR/P/B | PR/P/B | 1000: 1 (7.5-16 IS 3000: 1) | 1000: 1 (7.5-16 is 3000: 1) | - | - | - | - | - | - | - | Yes (PR/P) | Yes (PR/P) | - | - | - | - | IP65, NEMA4X | IP65, NEMA4X | 600MPas (CP) | 600MPas (CP) | EXISTENCE | Existence | 15 | 19W | 15 | 19W | 1 | 1 | - | - | EXISTENCE | - | Yes (PR/P) | Existence | - | Yes (PR/P) | Yes (PR) | - | Yes (PR) | - | Five% | Five% | - | - | - | - | 60db (a) | 60db (a) | AC Single Phase 100 ~ 240V50/60Hz | AC single phase 100 ~ 240V50/60Hz | Yes (PR/P) | Yes (PR/P) | Yes (PR/P) | Yes (PR/P) | - | - | - | - | 3.2kg | 3.2kg | - | |
XL series DDA XL |
Available upon quote | EXISTENCE | Existence | EXISTENCE | Existence | EXISTENCE | EXISTENCE | EXISTENCE | Existence | Existence | Existence | Yes (FCM) | Yes (FCM) | EXISTENCE | Existence | EXISTENCE | Existence | EXISTENCE | FCM/AR | FCM/AR | 800: 1 | 800: 1 | Yes (AR) | EXISTENCE | EXISTENCE | Existence | Existence | Graphic Display | Yes (AR) | EXISTENCE | Existence | Yes (FCM) | Yes (FCM) | Yes (FCM) | Yes (FCM) | IP65, NEMA4X | IP65, NEMA4X | 3000MPas (CP) | 3000MPas (CP) | EXISTENCE | Existence | 200 | 62W | 200 | 62W | 1 | 1 | Yes (FCM) | Yes (FCM) | - | EXISTENCE | EXISTENCE | - | Existence | Existence | EXISTENCE | EXISTENCE | Existence | Existence | 1.5%(Set Value)+0.1%(FULL SCALE) | 1.5%(set value)+0.1%(full scale) | EXISTENCE | Existence | EXISTENCE | Existence | 80db (a) | 80db (a) | AC Single Phase 100 ~ 240V50/60Hz | AC single phase 100 ~ 240V50/60Hz | EXISTENCE | EXISTENCE | Existence | Existence | EXISTENCE | EXISTENCE | Existence | Existence | 9.1kg | 9.1kg | Graphic display | |
XL series DDE XL |
Available upon quote | Yes (AR) | Yes (AR) | Yes (AR) | Yes (AR) | Yes (AR) | - | - | Yes (AR) | - | - | - | - | - | - | - | - | - | AR/B | AR/B | 800: 1 | 800: 1 | - | - | - | - | - | - | - | Yes (AR) | Yes (AR) | - | - | - | - | IP65, NEMA4X | IP65, NEMA4X | 1000MPas (CP) | 1000MPas (CP) | EXISTENCE | Existence | 200 | 62W | 200 | 62W | 1 | 1 | - | - | - | Yes (AR) | Yes (AR) | - | Yes (AR) | Yes (AR) | Yes (AR) | - | Yes (AR) | - | 1.5%(Set Value)+0.1%(FULL SCALE) | 1.5%(set value)+0.1%(full scale) | - | - | - | - | 80db (a) | 80db (a) | AC Single Phase 100 ~ 240V50/60Hz | AC single phase 100 ~ 240V50/60Hz | Yes (AR) | Yes (AR) | Yes (AR) | Yes (AR) | - | - | - | - | 9.1kg | 9.1kg | - |
Click on the part number for more information about each product