All Categories
History
Product
High efficiency permanent magnet motor (PM motor) IE4Handling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Drive inverter | Power supply voltage (inverter power reception) | Power frequency (inverter power reception) | Heat resistance class | Type | Magnetic pole position detection | Purpose | Number of poles | Frame number | Rated rotation speed | Rated output | Rating | Paint color | Rotation direction | Ambient environmental conditions Altitude | Ambient environmental conditions Atmosphere | Ambient environmental conditions Installation location | Ambient environmental conditions Humidity | Ambient environmental conditions Temperature | Ambient environmental conditions Vibration | Meddling method | Reference standard | Protective structure | Conduction method | Motor efficiency | Torque characteristics Maximum torque | Torque characteristics Starting torque | Inverter carrier frequency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EHM2-003718 |
Available upon quote |
WJ200 series |
200~240V, 400~480V |
50/60Hz |
B |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
8 |
112M |
1,800min-1 |
3.7 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Terminal block (screwed) |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
8~15kHz |
|
EHM2-005518 |
Available upon quote |
WJ200 series |
200~240V, 400~480V |
50/60Hz |
B |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
8 |
132S |
1,800min-1 |
5.5 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Terminal block (screwed) |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
8~15kHz |
|
EHM2-007518 |
Available upon quote |
WJ200 series |
200~240V, 400~480V |
50/60Hz |
B |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
8 |
132M |
1,800min-1 |
7.5 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Terminal block (screwed) |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
8~15kHz |
|
EHM2-011018 |
Available upon quote |
WJ200 series |
200~240V, 400~480V |
50/60Hz |
B |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
160M |
1,800min-1 |
11 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
8~15kHz |
|
EHM2-015018 |
Available upon quote |
WJ200 series |
200~240V, 400~480V |
50/60Hz |
B |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
160L |
1,800min-1 |
15 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
8~15kHz |
|
EHM2-018518 |
Available upon quote |
WJ200 series |
200~240V, 400~480V |
50/60Hz |
F |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
180M |
1,800min-1 |
18.5 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
8~15kHz |
|
EHM2-022018 |
Available upon quote |
SJ series P1 |
200~240V, 400~480V |
50/60Hz |
F |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
180M |
1,800min-1 |
Twenty two |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
6~12kHz |
|
EHM2-030018 |
Available upon quote |
SJ series P1 |
200~240V, 400~480V |
50/60Hz |
F |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
180L |
1,800min-1 |
30 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
6~12kHz |
|
EHM2-037018 |
Available upon quote |
SJ series P1 |
200~240V, 400~480V |
50/60Hz |
F |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
200L |
1,800min-1 |
37 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
6~12kHz |
|
EHM2-045018 |
Available upon quote |
SJ series P1 |
200~240V, 400~480V |
50/60Hz |
F |
Permanent magnet synchronous motor |
No sensor included |
Reduced torque for fans, pumps, etc. |
6 |
200L |
1,800min-1 |
45 |
S1 (continuous rating) |
Rigel Gray (Munsell 8.9Y5.1/0.3) |
Counterclockwise when viewed from the load side |
Altitude below 1,000m |
A place free from corrosive and explosive gases, steam, condensation, and dust. |
Indoor |
20~90%RH |
-10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) |
4.9m/s2 (0.5G) |
Taking out the rug |
JIS C 4034 |
Totally enclosed external fan type (IP44) |
Direct connection only |
IE4: At rated output/rotation speed |
120% for 1 minute |
50% |
6~12kHz |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
38.9hrs
Company Review
5.0