Product Image | Part Number | Price (excluding tax) | Ambient environmental conditions Altitude | Ambient environmental conditions Atmosphere | Ambient environmental conditions Humidity | Ambient environmental conditions Installation location | Ambient environmental conditions Temperature | Ambient environmental conditions Vibration | Conduction method | Drive inverter | Frame number | Heat resistance class | Inverter carrier frequency | Magnetic pole position detection | Meddling method | Motor efficiency | Number of poles | Paint color | Power frequency (inverter power reception) | Power supply voltage (inverter power reception) | Protective structure | Purpose | Rated output | Rated rotation speed | Rating | Reference standard | Rotation direction | Torque characteristics Maximum torque | Torque characteristics Starting torque | Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EHM2-003718 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | WJ200 series | 112M | B | 8~15kHz | No sensor included | Terminal block (screwed) | IE4: At rated output/rotation speed | 8 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 3.7 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-005518 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | WJ200 series | 132S | B | 8~15kHz | No sensor included | Terminal block (screwed) | IE4: At rated output/rotation speed | 8 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 5.5 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-007518 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | WJ200 series | 132M | B | 8~15kHz | No sensor included | Terminal block (screwed) | IE4: At rated output/rotation speed | 8 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 7.5 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-011018 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | WJ200 series | 160M | B | 8~15kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 11 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-015018 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | WJ200 series | 160L | B | 8~15kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 15 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-018518 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | WJ200 series | 180M | F | 8~15kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 18.5 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-022018 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | SJ series P1 | 180M | F | 6~12kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | Twenty two | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-030018 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | SJ series P1 | 180L | F | 6~12kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 30 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-037018 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | SJ series P1 | 200L | F | 6~12kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 37 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor | |
EHM2-045018 |
Available upon quote | Altitude below 1,000m | A place free from corrosive and explosive gases, steam, condensation, and dust. | 20~90%RH | Indoor | -10℃~40℃ (If the motor is covered with a cover, etc., the temperature inside the cover is considered the ambient temperature.) | 4.9m/s2 (0.5G) | Direct connection only | SJ series P1 | 200L | F | 6~12kHz | No sensor included | Taking out the rug | IE4: At rated output/rotation speed | 6 | Rigel Gray (Munsell 8.9Y5.1/0.3) | 50/60Hz |
200~240V, 400~480V If the voltage is outside the above range, operation at the specified output, rotational speed, and temperature rise cannot be guaranteed. |
Totally enclosed external fan type (IP44) | Reduced torque for fans, pumps, etc. | 45 | 1,800min-1 | S1 (continuous rating) | JIS C 4034 | Counterclockwise when viewed from the load side | 120% for 1 minute | 50% | Permanent magnet synchronous motor |