Hydrogen/helium analyzer HSense-HSense
Hydrogen/helium analyzer HSense-Iwata Dengyo Co., Ltd.

Hydrogen/helium analyzer HSense
Iwata Dengyo Co., Ltd.


About This Product

■Summary HSense is a process mass spectrometer for hydrogen and helium that is based on a magnetic field deflection mass spectrometer (SF-MS) and is optimized for rapid and highly accurate measurements of hydrogen and helium. Hydrogen and helium ions ionized by electron collisions are accelerated in a magnetic field with constant energy, focused, and separated, and detected with a response time of less than 1 second. The gas conditioning unit installed as standard in the main unit is unaffected by changes in the water concentration in the sample gas. It supports flexible system configurations, such as as a dedicated stand-alone device, or by linking with the sister model AirSense (IMR-MS) to expand the range of gases to be measured.

  • Product

    Hydrogen/helium analyzer HSense

Share this product


100+ people viewing

Last viewed: 16 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Hydrogen/helium analyzer HSense

Product Image Part Number Price (excluding tax) Accuracy Ambient humidity Ambient temperature change Ambient temperature range Analysis time Communication Dimensions (body) Drift concentration Gas consumption Gas inlet pressure Gas inlet temperature Low concentration detection limit Mass range Measurement range Power supply Reproducibility Resolution Response time Wait time when starting the device Weight
Hydrogen/helium analyzer HSense-Part Number-HSense

HSense

Available upon quote > ± 2% Ambient humidity max. 80% (non-condensing) Within ±2.5℃ 10℃ - 35℃ >= 1 msec/amu Ethernet (100BASE-TX) RS-232 534 (W) X743 (H) X639 (D) (excluding protrusions) > ± 3% (24 h) Maximum 150 L/h (2.5L/min) -70~200kPa Maximum 190℃ > 1ppm (H2) > 20ppb (He) 2 – 4 amu 0-10,000 ppm, 0-50,000 ppm, 0-100 vol% Single phase AC200V 600W > ± 3% < 1 amu T90 > 1 sec Allow at least 10 minutes to begin vacuuming the instrument and enter operation. We recommend stabilization in standby mode for at least 12 hours before starting measurement. 65kg