Product
Small high frequency induction heating device MU-α seriesHandling Company
SK Medical Electronics Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | High frequency output | Power supply voltage | Automatic control | Oscillation frequency | Temperature input | General purpose input/output | Manual control Constant temperature control | Manual control Constant output control | Safety equipment | External dimensions/weight heating part | External dimensions/weight control section | Cooling method | Resonance method | Storage ambient temperature | Usage environment | Operating ambient temperature | Amount of cooling water used | Remote control | Switching method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MU-αⅢ |
Available upon quote |
Maximum (regular use) 4kW (2kW) |
Single phase AC200V±10%, 50/60Hz±5% |
Program output/temperature control (number of programs: 10, number of steps: 15/1 program) |
350~450kHz (depending on heating coil specifications) |
Thermocouple (K,J,E,W,N,R,S,B,T) Radiation thermometer (220-2,000, 300-2,000, 600-2,000, 600-3,000℃) |
Input: 8 points (1 point is only for emergency stop) Output: 8 points (DC24V, 20mA) |
Temperature adjustment by volume (room temperature to maximum value, 1℃ increments) |
Output adjustment by volume (0~100%, 0.1% increments) |
Earth leakage breaker, fast-acting fuse, cooling water flow rate, temperature, water leakage detection, resonance monitoring, sensor abnormality (disconnection detection), upper/lower temperature limits, overcurrent, emergency stop, etc. |
400×300×300mm (15kg) |
400×300×300mm (15kg) |
Water cooling type (heating coil, resonance capacitor, high frequency transformer, switching element) ・Cooling fan |
LC series resonance |
-10~60℃ (85%RH or less) No condensation or freezing |
Indoor use, altitude below 2,000m, pollution level 2 |
5~40℃ (20~85%RH) No condensation |
Approximately 1.0L/min (at water pressure 0.25MPa) |
Control by external signal (4~20mA) |
Power MOS-FET full bridge inverter |
|
MU-αⅣ |
Available upon quote |
Maximum (regular use) 6kW (6kW) |
Single phase AC200V±10%, 50/60Hz±5% |
Program output/temperature control (number of programs: 10, number of steps: 15/1 program) |
350~450kHz (depending on heating coil specifications) |
Thermocouple (K,J,E,W,N,R,S,B,T) Radiation thermometer (220-2,000, 300-2,000, 600-2,000, 600-3,000℃) |
Input: 8 points (1 point is only for emergency stop) Output: 8 points (DC24V, 20mA) |
Temperature adjustment by volume (room temperature to maximum value, 1℃ increments) |
Output adjustment by volume (0~100%, 0.1% increments) |
Earth leakage breaker, fast-acting fuse, cooling water flow rate, temperature, water leakage detection, resonance monitoring, sensor abnormality (disconnection detection), upper/lower temperature limits, overcurrent, emergency stop, etc. |
400×500×320mm (31kg) |
300×300×280mm (12kg) |
Water cooling type (heating coil, resonance capacitor, high frequency transformer, switching element) ・Cooling fan |
LC series resonance |
-10~60℃ (85%RH or less) No condensation or freezing |
Indoor use, altitude below 2,000m, pollution level 2 |
5~40℃ (20~85%RH) No condensation |
Approx. 3.5L/min (at water pressure 0.25MPa) |
Control by external signal (4~20mA) |
Power MOS-FET full bridge inverter |