All Categories

History

High-speed response digital flow indicator FM series-FM22-AV-RS-C
High-speed response digital flow indicator FM series-Nippon Tescon Co., Ltd.

High-speed response digital flow indicator FM series
Nippon Tescon Co., Ltd.

Nippon Tescon Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

122.1hours


About This Product

The FM series is a low-cost type flow meter. It adopts a periodic calculation method and supports high-speed calculation and high-speed output. ・FM22: Instantaneous flow rate indicator ・FM23P: Instantaneous/integrated flow rate switching display type ・FM34: Integration counter (addition and subtraction operations possible) ・FM25: Ratio meter ・RoHS Directive compliant product ・Panel front protection class IP65 ・48H×96W×92Dmm short body type *Other product numbers are available.

  • Product

    High-speed response digital flow indicator FM series

Share this product


280+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of High-speed response digital flow indicator FM series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Setting value memory Measurement type Display section Display range Display moving average Display unit Display switching cycle Decimal point display External control terminal Operation method Prediction calculation Zero reset time Scaling function Sampling period HOLD terminal CNT terminal 20-point broken line correction
High-speed response digital flow indicator FM series-Part Number-FM22-AV-RS-C

FM22-AV-RS-C

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22-AV-RS-F

FM22-AV-RS-F

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22-AV-RS-N

FM22-AV-RS-N

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22-AI-RS-C

FM22-AI-RS-C

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22-AI-RS-F

FM22-AI-RS-F

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22-AI-RS-N

FM22-AI-RS-N

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22D-AV-RS-C

FM22D-AV-RS-C

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22D-AV-RS-F

FM22D-AV-RS-F

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22D-AV-RS-N

FM22D-AV-RS-N

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

High-speed response digital flow indicator FM series-Part Number-FM22D-AI-RS-C

FM22D-AI-RS-C

Available upon quote

By EEPROM (10 years/time)

Moving average of 1 to 100 times for both sampling period calculation and 1 period calculation

7 segment red LED display Character height: 14.2mm Zero suppression display

0~999,999 6 digit display

1 to 20 times (target is display cycle data)

/h, /min, /sec selection

0.1/0.2/0.5/1~10 (seconds)

0/0.0/0.00/0.000/0.0000/0.00000

Negative logic input minimum ON width: 20msec Internal resistance 1.5KΩ

CPU cycle calculation method

It detects deceleration and predictably lowers the measured value. Updated every 10msec.

1sec~1,000sec

10^-9×0.00001^2~10^9×999,999^2 (target is input frequency)

1/10/20/50/100msec selectable

HOLD/MAX/MIN/P-P hold functions can be selected.

Zero reset/comparison output retention

Up to 20 points can be set for the relationship between frequency and display value. (Option:-L)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Flowmeters Products

Other products of Nippon Tescon Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Nippon Tescon Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

122.1hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree