Product
NDIR non -dispersed infrared light carbon dioxide detection alarmHandling Company
New Cosmos ElectricProduct Image | Part Number | Price (excluding tax) | A warning delay | Alarm accuracy | Alarm display | Alarm mode | Alarm setting value | Conjunction | Detection principle | Detection range | Gas to be detected | Operating temperature limit | Paint color | Repetition | Used humidity range | power consumption | power supply | size | structure | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IRC-630 |
Available upon quote | Within 20 seconds (with 1.6 times gas of the alarm setting) | ± 25%or less of the alarm setting value (under the same condition) | Red lamp lighting and buzzer sound when the set value is exceeded | Automatic return (self -maintenance is also possible) | Violation can be set within the measurement range (two -stage warning type is also possible, but alarm output 1A) | RC1/4 | Non -dispersed infrared light | 0 ~ 5vol % 0-2.5vol % 0 to 1Vol % 0 ~ 5000pm0 to 2500PPM | carbon dioxide | 0 to 40 ° C | Mancel 5y7/1 | ± 2 % of full scale | 35-95 % RH (but not condensation) | Approximately 30va | AC100V ± 10 % 50/60Hz | W200 x H390 x D113mm (excluding protrusions) | Wall -mounted drip -proof structure pump suction type | Approximately 6kg |