■Tubular furnace type sulfur/carbon analyzer that continues to be a long-selling product using LECO's unique technology The SC832 is an ASTM (American Society for Testing and Materials) certified sulfur and carbon analyzer using combustion, non-dispersive infrared absorption method. The latest analyzer, developed using extensive customer feedback and innovative technology, features a mount-type monitor that improves operability and allows for operational management without wasting valuable space. can. Carbon and sulfur in coal, coke, cement, soil, fuel oil, and other organic compounds can be analyzed accurately and quickly. This series has a long history among LECO products due to its ``high-accuracy and rapid analysis'', ``easy maintenance and excellent durability'', ``space saving'', and ``easy-to-use software'', and is constantly evolving to meet the needs of the times. This is a device that continues to do so. With its high-efficiency combustion furnace, improved IR cell, and robustness, the 832 Series meets your needs for fast and accurate analysis of sulfur and carbon in all organic compounds. ■Analysis target Coal, coke, cement, petroleum products, ore, soil, catalyst, rubber, etc. Features and benefits ■High efficiency combustion furnace ・LECO's unique horizontal furnace that can be set up to a maximum of 1,550℃ uses a lance system that sprays oxygen directly onto the sample, allowing for rapid complete combustion and complete recovery of carbon and sulfur. -Analysis completes in approximately 2 minutes per sample. ・The new reactor, which is designed to be isolated from the atmosphere, can reduce blank values ​​and improve analysis accuracy. ・Reduced power consumption and waste heat, dramatically reducing operating costs. ■IR cell ・By optimizing the emitter control and detector circuit, we have achieved long life and long-term stability of the IR cell. ・The S/C/SC832 standard model is equipped with one wide range IR detector for carbon and sulfur analysis, simplifying calibration and condition settings. - The optional S/SC832DR model is equipped with two IR detectors for sulfur analysis, and can be applied to a wide range of analyzes from trace amounts to high concentration ranges.

  • Product

    Organic analysis sulfur carbon analyzer SC832 type

Share this product


210+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

5 Models of Organic analysis sulfur carbon analyzer SC832 type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analysis accuracy *Whichever is greater Analysis range (sample weight 200 mg) Analysis time Detection method Furnace Gas used Heater section Option Part number 1 Part number 2 Power capacity Reagents used Sample weight Size Weight
Organic analysis sulfur carbon analyzer SC832 type-Part Number-SC832

SC832

Available upon quote Sulfur: Standard deviation (s) 0.004 mg or RSD 1%
Sulfur (DR): Standard deviation (s) 0.0018 mg or RSD 1%
Carbon: Standard deviation (s) 0.0088 mg or RSD 1%
Sulfur: 0.008 mg~30 mg (0.004%~15%)
Carbon: 0.0175 mg~200 mg (0.009%~100%)
60~120 seconds (typical) Non-dispersive infrared absorption method 832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃)
832HT: Resistance heating furnace 600℃~1550℃ (set value ±10℃)
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge Made of molybdenum disilicide / 4 pieces Performance package (P); Leak check function and back pressure adjustment function
Desktop type monitors are also available.
S832MC: Sulfur analyzer
C832MC: Carbon analyzer
SC832MC: Sulfur carbon analyzer
S832DR-MC: Dual range sulfur analyzer
SC832DR-MC: Dual range sulfur carbon analyzer
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) Magnesium perchlorate (Anhydron) Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm 88 kg (with mount monitor), 78 kg (without mount monitor)
Organic analysis sulfur carbon analyzer SC832 type-Part Number-SC832DR

SC832DR

Available upon quote Sulfur: Standard deviation (s) 0.004 mg or RSD 1%
Sulfur (DR): Standard deviation (s) 0.0018 mg or RSD 1%
Carbon: Standard deviation (s) 0.0088 mg or RSD 1%
Sulfur: 0.0035 mg~98 mg (0.002%~49%)
Carbon: 0.0175 mg**~200 mg (0.009%~100%)
60~120 seconds (typical) Non-dispersive infrared absorption method 832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃)
832HT: Resistance heating furnace 600℃~1550℃ (set value ±10℃)
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge Made of molybdenum disilicide / 4 pieces Performance package (P); Leak check function and back pressure adjustment function
Desktop type monitors are also available.
S832MC: Sulfur analyzer
C832MC: Carbon analyzer
SC832MC: Sulfur carbon analyzer
S832DR-MC: Dual range sulfur analyzer
SC832DR-MC: Dual range sulfur carbon analyzer
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) Magnesium perchlorate (Anhydron) Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm 88 kg (with mount monitor), 78 kg (without mount monitor)
Organic analysis sulfur carbon analyzer SC832 type-Part Number-S832

S832

Available upon quote Sulfur: Standard deviation (s) 0.004 mg or RSD 1%
Sulfur (DR): Standard deviation (s) 0.0018 mg or RSD 1%
Carbon: Standard deviation (s) 0.0088 mg or RSD 1%
- 60~120 seconds (typical) Non-dispersive infrared absorption method 832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃)
832HT: Resistance heating furnace 600℃~1550℃ (set value ±10℃)
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge Made of molybdenum disilicide / 4 pieces Performance package (P); Leak check function and back pressure adjustment function
Desktop type monitors are also available.
S832MC: Sulfur analyzer
C832MC: Carbon analyzer
SC832MC: Sulfur carbon analyzer
S832DR-MC: Dual range sulfur analyzer
SC832DR-MC: Dual range sulfur carbon analyzer
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) Magnesium perchlorate (Anhydron) Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm 88 kg (with mount monitor), 78 kg (without mount monitor)
Organic analysis sulfur carbon analyzer SC832 type-Part Number-S832DR

S832DR

Available upon quote Sulfur: Standard deviation (s) 0.004 mg or RSD 1%
Sulfur (DR): Standard deviation (s) 0.0018 mg or RSD 1%
Carbon: Standard deviation (s) 0.0088 mg or RSD 1%
Sulfur (DR): 0.0035 mg~98 mg (0.002%~49%)
Carbon: 0.0175 mg~200 mg (0.009%~100%)
60~120 seconds (typical) Non-dispersive infrared absorption method 832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃)
832HT: Resistance heating furnace 600℃~1550℃ (set value ±10℃)
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge Made of molybdenum disilicide / 4 pieces Performance package (P); Leak check function and back pressure adjustment function
Desktop type monitors are also available.
S832MC: Sulfur analyzer
C832MC: Carbon analyzer
SC832MC: Sulfur carbon analyzer
S832DR-MC: Dual range sulfur analyzer
SC832DR-MC: Dual range sulfur carbon analyzer
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) Magnesium perchlorate (Anhydron) Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm 88 kg (with mount monitor), 78 kg (without mount monitor)
Organic analysis sulfur carbon analyzer SC832 type-Part Number-C832

C832

Available upon quote Sulfur: Standard deviation (s) 0.004 mg or RSD 1%
Sulfur (DR): Standard deviation (s) 0.0018 mg or RSD 1%
Carbon: Standard deviation (s) 0.0088 mg or RSD 1%
Carbon: 0.0175 mg~200 mg (0.009%~100%) 60~120 seconds (typical) Non-dispersive infrared absorption method 832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃)
832HT: Resistance heating furnace 600℃~1550℃ (set value ±10℃)
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge Made of molybdenum disilicide / 4 pieces Performance package (P); Leak check function and back pressure adjustment function
Desktop type monitors are also available.
S832MC: Sulfur analyzer
C832MC: Carbon analyzer
SC832MC: Sulfur carbon analyzer
S832DR-MC: Dual range sulfur analyzer
SC832DR-MC: Dual range sulfur carbon analyzer
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) Magnesium perchlorate (Anhydron) Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm 88 kg (with mount monitor), 78 kg (without mount monitor)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of LECO Japan LLC


View more products of LECO Japan LLC

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree