All Categories
History
Response Rate
100.0%
Response Time
126.8hours
Product
Organic analysis sulfur carbon analyzer SC832 typeHandling Company
LECO Japan LLCCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power capacity | Weight | Sample weight | Furnace | Detection method | Size | Analysis accuracy *Whichever is greater | Analysis range (sample weight 200 mg) | Analysis time | Reagents used | Gas used | Heater section | Part number 2 | Part number 1 | Option |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SC832 |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) |
88 kg (with mount monitor), 78 kg (without mount monitor) |
Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) |
832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃) |
Non-dispersive infrared absorption method |
Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm |
Sulfur: Standard deviation (s) 0.004 mg or RSD 1% |
Sulfur: 0.008 mg~30 mg (0.004%~15%) |
60~120 seconds (typical) |
Magnesium perchlorate (Anhydron) |
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge |
Made of molybdenum disilicide / 4 pieces |
S832DR-MC: Dual range sulfur analyzer |
S832MC: Sulfur analyzer |
Performance package (P); Leak check function and back pressure adjustment function |
![]() |
SC832DR |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) |
88 kg (with mount monitor), 78 kg (without mount monitor) |
Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) |
832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃) |
Non-dispersive infrared absorption method |
Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm |
Sulfur: Standard deviation (s) 0.004 mg or RSD 1% |
Sulfur: 0.0035 mg~98 mg (0.002%~49%) |
60~120 seconds (typical) |
Magnesium perchlorate (Anhydron) |
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge |
Made of molybdenum disilicide / 4 pieces |
S832DR-MC: Dual range sulfur analyzer |
S832MC: Sulfur analyzer |
Performance package (P); Leak check function and back pressure adjustment function |
![]() |
S832 |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) |
88 kg (with mount monitor), 78 kg (without mount monitor) |
Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) |
832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃) |
Non-dispersive infrared absorption method |
Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm |
Sulfur: Standard deviation (s) 0.004 mg or RSD 1% |
- |
60~120 seconds (typical) |
Magnesium perchlorate (Anhydron) |
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge |
Made of molybdenum disilicide / 4 pieces |
S832DR-MC: Dual range sulfur analyzer |
S832MC: Sulfur analyzer |
Performance package (P); Leak check function and back pressure adjustment function |
![]() |
S832DR |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) |
88 kg (with mount monitor), 78 kg (without mount monitor) |
Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) |
832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃) |
Non-dispersive infrared absorption method |
Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm |
Sulfur: Standard deviation (s) 0.004 mg or RSD 1% |
Sulfur (DR): 0.0035 mg~98 mg (0.002%~49%) |
60~120 seconds (typical) |
Magnesium perchlorate (Anhydron) |
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge |
Made of molybdenum disilicide / 4 pieces |
S832DR-MC: Dual range sulfur analyzer |
S832MC: Sulfur analyzer |
Performance package (P); Leak check function and back pressure adjustment function |
![]() |
C832 |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 14 A (maximum), 5 A (standby), 5,100 BTU/hr (during analysis), 3,100 BTU/hr (standby) |
88 kg (with mount monitor), 78 kg (without mount monitor) |
Normal Sulfur only: 350 mg (coal), Carbon/Sulfur: 200 mg (coal) |
832/832DR: Resistance heating furnace 600℃~1450℃ (set value ±10℃) |
Non-dispersive infrared absorption method |
Width: 46 cm x Depth: 79 cm (66 cm) x Height: 80 cm |
Sulfur: Standard deviation (s) 0.004 mg or RSD 1% |
Carbon: 0.0175 mg~200 mg (0.009%~100%) |
60~120 seconds (typical) |
Magnesium perchlorate (Anhydron) |
Oxygen 99.5%, 0.1 MPa ±10%, 3.5 L/min, 1.0 L/min/purge |
Made of molybdenum disilicide / 4 pieces |
S832DR-MC: Dual range sulfur analyzer |
S832MC: Sulfur analyzer |
Performance package (P); Leak check function and back pressure adjustment function |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
126.8hrs