Organic elemental analyzer CNS928 typeHandling Company
LECO Japan LLCCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power capacity | Weight | Sample amount | Furnace | Detection method | Dimensions body and autoloader | Operating environment | Analysis accuracy Carrier gas 《3 cm3 loop》 | Analysis accuracy Carrier gas《10 cm3 loop》 | Analysis range Carrier gas 《3 cm3 loop》 | Analysis range Carrier gas《10 cm3 loop》 | Gas used | Gas used Combustion | Gas carrier used | Cycle time (EDTA, normal sample amount) | Autoloader |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CNS928 |
Available upon quote |
200 V (+10%/-15%, boosted to 230 V), 50/60 Hz, single phase 14 A (maximum), 6 A (standby), 4,100 BTU/hr during analysis |
Main unit, autoloader approximately 178 kg Monitor 10 kg |
Nitrogen (FP) up to 3.0 g, typical 1.0 g |
Resistance heating furnace 600℃ – 1,450℃ ±10℃ |
Nitrogen: thermal conductivity method |
Height: 112 cm x Width: 150 cm x Depth: 76 cm |
Temperature: 15℃~35℃ |
Helium Sulfur 0.02 mg or 0.8% RSD |
Helium Sulfur 0.01 mg or 0.4% RSD |
Helium Sulfur 0.04 mg~50 mg |
Helium Sulfur 0.02 mg~50 mg |
Compressed air or nitrogen (no moisture or oil), 0.28 MPa ±10% |
Oxygen (99.9%), 0.17 MPa ±10% |
Helium (99.99%), 0.17 MPa ±10% |
5 minutes (12 samples/hour) |
100 samples |
|
FP928 |
Available upon quote |
200 V (+10%/-15%, boosted to 230 V), 50/60 Hz, single phase 14 A (maximum), 6 A (standby), 4,100 BTU/hr during analysis |
Main unit, autoloader approximately 178 kg Monitor 10 kg |
Nitrogen (FP) up to 3.0 g, typical 1.0 g |
Resistance heating furnace 600℃ – 1,450℃ ±10℃ |
Nitrogen: thermal conductivity method |
Height: 112 cm x Width: 150 cm x Depth: 76 cm |
Temperature: 15℃~35℃ |
Helium Nitrogen 0.02 mg or 0.6% RSD |
Helium Nitrogen 0.01 mg or 0.3% RSD |
Helium Nitrogen 0.04 mg~300 mg |
Helium Nitrogen 0.02 mg~300 mg |
Compressed air or nitrogen (no moisture or oil), 0.28 MPa ±10% |
Oxygen (99.9%), 0.17 MPa ±10% |
Helium (99.99%), 0.17 MPa ±10% |
5 minutes (12 samples/hour) |
100 samples |
|
CN928 |
Available upon quote |
200 V (+10%/-15%, boosted to 230 V), 50/60 Hz, single phase 14 A (maximum), 6 A (standby), 4,100 BTU/hr during analysis |
Main unit, autoloader approximately 178 kg Monitor 10 kg |
Nitrogen (FP) up to 3.0 g, typical 1.0 g |
Resistance heating furnace 600℃ – 1,450℃ ±10℃ |
Nitrogen: thermal conductivity method |
Height: 112 cm x Width: 150 cm x Depth: 76 cm |
Temperature: 15℃~35℃ |
Helium Carbon 0.02 mg or 0.8% RSD |
Helium Carbon 0.01 mg or 0.4% RSD |
Helium Carbon 0.04 mg~200 mg |
Helium Carbon 0.02 mg~200 mg |
Compressed air or nitrogen (no moisture or oil), 0.28 MPa ±10% |
Oxygen (99.9%), 0.17 MPa ±10% |
Helium (99.99%), 0.17 MPa ±10% |
5 minutes (12 samples/hour) |
100 samples |