Inorganic analysis hydrogen analyzer model DH603Handling Company
LECO Japan LLCCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Analysis range (sample weight 1 g) | Analytical accuracy (sample weight 1 g) | Calibration | Detection method | Dimensions/weight | Furnace | Gas flow rate | Gas used Carrier gas | Gas used Gas dose | Installation conditions | Minimum read | Option | Power capacity | Reagents used | Sample size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DH603 |
Available upon quote |
Hydrogen 0.1 ppm~2500 ppm *The analysis range can be widened by changing the sample weight. |
Hydrogen: Standard deviation (s) 0.02 ppm or RSD 2% *Whichever is greater | Standard material / multi-point / gas dose | Thermal conductivity method | Width: 57 cm x Depth: 70 cm x Height: 84 cm | Resistance heating furnace (room temperature to 1100℃) Temperature and heating rate can be programmed |
3 L/min (in operation) 0.25 L/min (standby) |
Nitrogen purity 99.99%, 0.21 MPa ±10%, Nitrogen purity 99.99%, 0.41 MPa ±10% (with diffusible hydrogen option) | Helium purity 99.99%, 0.14 MPa ±10% |
Temperature: 15℃~35℃ Relative humidity: 20%~80% (non-condensing) |
Hydrogen: 0.001 ppm |
625-515 Upgrade Kit (DH603 → DH603DC) |
Single phase 200 V~ (±10%: maximum output, boosted to 230 V), 50/60 Hz, 35 A, 23,600 BTU/hr *Average during normal operation. | Magnesium perchlorate Mg (ClO4) 2 / Sodium hydroxide (NaOH) / Copper oxide (CuO) | For non-diffusible hydrogen / max. 23 × 102 mm | |
DH603DC |
Available upon quote |
Hydrogen 0.1 ppm~2500 ppm *The analysis range can be widened by changing the sample weight. |
Hydrogen: Standard deviation (s) 0.02 ppm or RSD 2% *Whichever is greater | Standard material / multi-point / gas dose | Thermal conductivity method | Width: 57 cm x Depth: 70 cm x Height: 84 cm | Resistance heating furnace (room temperature to 1100℃) Temperature and heating rate can be programmed |
3 L/min (in operation) 0.25 L/min (standby) |
Nitrogen purity 99.99%, 0.21 MPa ±10%, Nitrogen purity 99.99%, 0.41 MPa ±10% (with diffusible hydrogen option) | Helium purity 99.99%, 0.14 MPa ±10% |
Temperature: 15℃~35℃ Relative humidity: 20%~80% (non-condensing) |
Hydrogen: 0.001 ppm |
625-515 Upgrade Kit (DH603 → DH603DC) |
Single phase 200 V~ (±10%: maximum output, boosted to 230 V), 50/60 Hz, 35 A, 23,600 BTU/hr *Average during normal operation. | Magnesium perchlorate Mg (ClO4) 2 / Sodium hydroxide (NaOH) / Copper oxide (CuO) | For non-diffusible hydrogen / max. 23 × 102 mm | |
DH603C |
Available upon quote |
Hydrogen 0.1 ppm~2500 ppm *The analysis range can be widened by changing the sample weight. |
Hydrogen: Standard deviation (s) 0.02 ppm or RSD 2% *Whichever is greater | Standard material / multi-point / gas dose | Thermal conductivity method | Width: 57 cm x Depth: 70 cm x Height: 84 cm | Resistance heating furnace (room temperature to 1100℃) Temperature and heating rate can be programmed |
3 L/min (in operation) 0.25 L/min (standby) |
Nitrogen purity 99.99%, 0.21 MPa ±10%, Nitrogen purity 99.99%, 0.41 MPa ±10% (with diffusible hydrogen option) | Helium purity 99.99%, 0.14 MPa ±10% |
Temperature: 15℃~35℃ Relative humidity: 20%~80% (non-condensing) |
Hydrogen: 0.001 ppm |
625-515 Upgrade Kit (DH603 → DH603DC) |
Single phase 200 V~ (±10%: maximum output, boosted to 230 V), 50/60 Hz, 35 A, 23,600 BTU/hr *Average during normal operation. | Magnesium perchlorate Mg (ClO4) 2 / Sodium hydroxide (NaOH) / Copper oxide (CuO) | For non-diffusible hydrogen / max. 23 × 102 mm |