All Categories
History
Response Rate
100.0%
Response Time
126.8hours
Product
Inorganic analysis carbon sulfur analyzer CS744 typeHandling Company
LECO Japan LLCCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power capacity | Weight | Reagent | Sample weight | Furnace | Detection method | Dimensions (with touch screen monitor) | Operating environment | Analytical accuracy (sample weight 1 g) | Analysis range (sample weight 1 g) | Analysis time | Processing capacity | Gas used | Cycle time | Calibration | Gas flow rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CS744 |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 30 A, 5,500 BTU/hr |
Body weight 140 kg (with touch screen monitor) 132 kg (without touch screen monitor) |
・Magnesium perchlorate |
Usually 1 g |
High frequency furnace 2.2 kW |
Non-dispersive infrared absorption method |
Width: 59 cm x Depth: 75 cm x Height: 84 cm |
Temperature: 15℃~35℃ |
Carbon: Standard deviation (s) 0.001 mg or RSD 0.5% *Whichever is larger |
Carbon: 0.002 mg~60 mg (2 ppm~6%) |
40 seconds (typical) |
27 samples/hour (typical) |
Carrier: Oxygen 99.5% (0.24 MPa) |
130 seconds (typical) |
Standard sample (1 point or multiple points), automatic or manual |
Carrier: 3 L/min |
![]() |
C744 |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 30 A, 5,500 BTU/hr |
Body weight 140 kg (with touch screen monitor) 132 kg (without touch screen monitor) |
・Magnesium perchlorate |
Usually 1 g |
High frequency furnace 2.2 kW |
Non-dispersive infrared absorption method |
Width: 59 cm x Depth: 75 cm x Height: 84 cm |
Temperature: 15℃~35℃ |
Carbon: Standard deviation (s) 0.001 mg or RSD 0.5% *Whichever is larger |
Carbon: 0.002 mg~60 mg (2 ppm~6%) |
40 seconds (typical) |
27 samples/hour (typical) |
Carrier: Oxygen 99.5% (0.24 MPa) |
130 seconds (typical) |
Standard sample (1 point or multiple points), automatic or manual |
Carrier: 3 L/min |
![]() |
S744 |
Available upon quote |
Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 30 A, 5,500 BTU/hr |
Body weight 140 kg (with touch screen monitor) 132 kg (without touch screen monitor) |
・Magnesium perchlorate |
Usually 1 g |
High frequency furnace 2.2 kW |
Non-dispersive infrared absorption method |
Width: 59 cm x Depth: 75 cm x Height: 84 cm |
Temperature: 15℃~35℃ |
Carbon: Standard deviation (s) 0.001 mg or RSD 0.5% *Whichever is larger |
Carbon: 0.002 mg~60 mg (2 ppm~6%) |
40 seconds (typical) |
27 samples/hour (typical) |
Carrier: Oxygen 99.5% (0.24 MPa) |
130 seconds (typical) |
Standard sample (1 point or multiple points), automatic or manual |
Carrier: 3 L/min |