Inorganic analysis carbon sulfur analyzer CS844 type
LECO Japan LLC


About This Product

■Features It is easy to use with an easy-to-operate touch screen attached to an adjustable 6-way flexible arm. No tools are required to remove the auto cleaner ■Analysis target Steel, cast iron, ferroalloy, mold powder, copper alloy, aluminum alloy, catalyst, ceramics, limestone, ore, etc. The CS844 is a wide range carbon and sulfur analyzer that uses cutting-edge technology to fulfill customer feedback and requests over many years. Carbon and sulfur in all inorganic materials such as metals, ores, and ceramics are measured using the combustion method. All operations such as instrument control, analysis condition settings, diagnostics and report printing are performed via a Windows®-based touchscreen interface mounted on the flexible arm, saving valuable work space. There is nothing wrong. Features and benefits ■High efficiency combustion furnace - Burns a wide variety of samples more efficiently. ・We reviewed the maintenance method and reduced the frequency of regular maintenance. ■Improved IR cell design - Improved accuracy and more accurate results. - Modular and easy to replace. No adjustment is required after replacement. - Improved stability during use and longer life. ・It has a configuration with two detectors each for carbon and sulfur. ■Highly reliable automation mechanism - Shuttle loaders for 10 samples and 60 samples are available. - Highly efficient auto-cleaner/vacuum system minimizes maintenance. ・Equipped with an automatic combustion tube exchange system as standard. ■Others -Ergonomic and intuitive operation is possible with the touch panel interface attached to the flexible arm. ・Pressure-compensated, temperature-controlled gas dosing system. - The latest piping minimizes joints that can cause damage or leaks.

  • Product

    Inorganic analysis carbon sulfur analyzer CS844 type

Share this product


240+ people viewing

Last viewed: 10 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Inorganic analysis carbon sulfur analyzer CS844 type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analysis accuracy carbon Analysis accuracy sulfur Analysis range Sulfur Analysis range carbon Analysis time Calibration Cycle time Detection method Dimensions (with touch screen monitor) Furnace Gas carrier used Gas flow rate Gas used Gas used Gas dosing Internal cooling water Operating environment Operation Power capacity Processing capacity Reagent Sample weight Weight

CS844

Available upon quote Standard deviation (s) 0.0003 mg (0.3 ppm) or RSD 0.5% *Whichever is greater Standard deviation (s) 0.0003 mg (0.3 ppm) or RSD 0.5% *Whichever is greater 0.0006 mg~60 mg (0.6 ppm~6.0% for 1 g sample) 0.0006 mg~60 mg (0.6 ppm~6.0% for 1 g sample) 40 seconds (typical) Standard sample (1 point or multiple points), automatic or manual 130 seconds (typical) Non-dispersive infrared absorption method Width: 59 cm x Depth: 75 cm x Height: 84 cm High frequency furnace, maximum 2.2 kw (heating 0~100% power), water cooling type Oxygen 99.5% (0.24 MPa) Carrier: 3 L/min
Drive: 1 L/min
Compressed air or nitrogen (0.28 MPa; no moisture or oil) Carbon dioxide 99.99% (0.14 MPa) 300mL, LECO Coolant Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
- Single phase 200 V~ (+10/-15%: maximum output, boosted to 230 V), 50/60 Hz, 30 A, 5,500 BTU/hr 27 samples/hour (typical) ・Magnesium perchlorate
・Sodium hydroxide (coding on inert substrate)
・Platinum silica gel
・Rare earth based copper oxide
·cellulose
Usually 1 g Body weight 140 kg (with touch screen monitor), 132 kg (without touch screen monitor)

CS844ES

Available upon quote Standard deviation (s) 0.3 ppm or RSD 0.5% *Whichever is larger (Standard mode): Standard deviation (s) 0.3 ppm or RSD 0.5% *Whichever is larger
(ES mode): Standard deviation (s) 0.05 ppm or RSD 0.5% *Whichever is larger
(Standard mode): 0.0006 mg~60 mg (0.6 ppm~6%)
(ES mode): 0.0001 mg~0.05 mg (0.1 ppm~50 ppm)
0.0006 mg~60 mg (0.6 ppm~6%) Standard mode: 40 seconds ES mode: 130 seconds Standards (single or multipoint), automatic or manual Standard mode: 130 seconds ES mode: 270 seconds Non-dispersive infrared absorption method Height: 84 cm, Width: 64 cm, Depth: 75 cm (including mounted touchscreen) High frequency furnace, maximum 2.2 kW (0-100% output control), water-cooled Oxygen (99.5%), 0.24 MPa ±10% Carrier gas: 3 L/min (ES mode: 0.8 L/min)
Driving gas: 1 L/min
Compressed air or nitrogen (no moisture or oil), 0.28 MPa ±10% Carbon dioxide (99.99%), 0.14 MPa ±10% 300mL, LECO Coolant Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
Windows software Single phase 200 V~ (+10/-15%, boosted to 230 V), 50/60 Hz, 30 A, 5,500 BTU/hr - ・Sodium hydroxide (coated on an inert substrate)
・Magnesium perchlorate
・Platinum silica gel
・Rare earth based copper oxide
·cellulose
Usually 1.0 g Body: 140 kg (including monitor), 132 kg (without monitor)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of LECO Japan LLC


View more products of LECO Japan LLC

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree