■Function These VCA and /VCN types are flowmeters for liquids that have some degree of lubrication. The measuring section of Kracht's flowmeter is based on the operating principle of a gear motor, and consists of two gears that are rotated by the flow of fluid. Plain bearings support gears in both radial and axial directions. Gear movement is detected non-contact by a sensor installed inside the cover. ■Transfer pump Lubricating oil supply equipment, transfer pump for dosing and mixing systems for low-pressure filling and lubrication ■Mobile Single and multi-stage high-pressure gear pumps, hydraulic motors, and valves for construction machinery and on-vehicle machinery. ■Flow rate measurement Gear and turbine type flow meters and indicators for volume and flow measurement technology related to hydraulics, processing, paints, etc. ■For general hydraulic industry CETOP., directional control valves, proportional valves, hydraulic cylinders, pressure controls, stop valves, etc., general industrial hydraulic equipment for piping and slab construction (fixed and mobile)

  • Product

    Gear type flowmeter VCA/VCN

Share this product


260+ people viewing

Last viewed: 4 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

9 Models of Gear type flowmeter VCA/VCN

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Fluid temperature Gear Housing, cover Impulse Installation position Measurement accuracy (flow range) Measuring range (l/min) Noise level Number of measurement channels Output Output power/channel Output pulse form Pairing Peak pressure Power consumption Protection class Pulse amplitude Starting point (l/min) Viscosity Volume per tooth (cm^3) Weight Working pressure (max.) Working voltage
Gear type flowmeter VCA/VCN-Part Number-VCA 0.04 FF R1

VCA 0.04 FF R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Stainless steel 1.4462 Aluminum AlMgSi F30 25,000 Freedom ±2% 20mm^2/s 0.02-4 (v=20mm^2/s) LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Ball bearing 240bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB 0.004 (v=20mm^2/s) Vmin=20mm^2/s
Vmax=4,000mm^2/s
0.04 0.5 200bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCN 0.04 FF R1

VCN 0.04 FF R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Stainless steel 1.4462 Stainless steel 1.4404 25,000 Freedom ±2% 20mm^2/s 0.02-4 (v=20mm^2/s) LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Ball bearing 190bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB 0.004 (v=20mm^2/s) Vmin=20mm^2/s
Vmax=4,000mm^2/s
0.04 1.2 160bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCA 0.1 FE R1

VCA 0.1 FE R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Cast iron 1.7139 Aluminum AlMgSi F30 10,000 Freedom ±2% 20mm^2/s 0.08-10 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Ball bearing 240bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB 0.008 (v=20mm^2/s) Vmin=20mm^2/s
Vmax=4,000mm^2/s
0.1 0.6 200bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCN 0.2 FA R1

VCN 0.2 FA R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Cast iron 1.7139 Aluminum hardening AlMgSi F30 5,000 Freedom ±3% 20mm^2/s 0.25-10 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Plastic Plain Bearing (Iglidur X) 200bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB - Vmin=20mm^2/s
Vmax=4,000mm^2/s
0.2 1.2 160bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCA 0.2 FB R1

VCA 0.2 FB R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Stainless steel 1.4462 Aluminum hardening AlMgSi F30 5,000 Freedom ±3% 20mm^2/s 0.25-10 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Plastic Plain Bearing (Iglidur X) 200bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB - Vmin=20mm^2/s
Vmax=4,000mm^2/s
0.2 0.5 160bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCN 0.2 FB R1

VCN 0.2 FB R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Stainless steel 1.4462 Stainless steel 1.4404 5,000 Freedom ±3% 20mm^2/s 0.25-10 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Plastic Plain Bearing (Iglidur X) 200bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB - Vmin=20mm^2/s
Vmax=4,000mm^2/s
0.2 0.5 160bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCA 2 FC R (P) 1

VCA 2 FC R (P) 1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Cast iron 1.7139 Aluminum hardening AlMgSi F30 50 Freedom ±2.5% 20mm^2/s 1-65 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Composite Plain Bearing (P10) 200bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB 0.12 (v=34mm^2/S
0.004 (v=100mm^2/s)
Vmin=20mm^2/s
Vmax=4,000mm^2/s
2 1.9 160bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCA 2 FB R (P) 1

VCA 2 FB R (P) 1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Stainless steel 1.4462 Aluminum hardening AlMgSi F30 500 Freedom ±2.5% 20mm^2/s 1-65 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Plastic Plain Bearing (Iglidur X) 200bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB 0.12 (v=34mm^2/S
0.004 (v=100mm^2/s)
Vmin=20mm^2/s
Vmax=4,000mm^2/s
2 1.9 160bar UB=12...30VDC
With polarity
Gear type flowmeter VCA/VCN-Part Number-VCA 05 FE R1

VCA 05 FE R1

Available upon quote Θmmin=-10℃
θmmax=+80℃
Θmmin=-10℃
θmmax=+80℃
Cast iron 1.7139 Aluminum hardening AlMgSi F30 191.5 Freedom ±1% 20mm^2/s 1-200 LA=<60dB (A) 1 PNP (NPN:Please contact us) Pamax=0.3W Short circuit prevention Rectangular wave
Pulse duty/channel
1:1±15%
Ball bearing 100bar Pbmax=0.6W IP 65 DIN 40050 UA≥0.8UB 0.1 (v=20mm^2/s) Vmin=20mm^2/s
Vmax=4,000mm^2/s
5.222 6 80bar UB=12...30VDC
With polarity

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Coco Research Co., Ltd.


View more products of Coco Research Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree