About This Product

■Maximum sampling rate 100kS/s, enabling high-resolution torque measurement

Simultaneously collects various mechanical quantities such as rotational speed, torque, angle, position, displacement, and pulse modulation, enabling data transmission with low loss.

■QuantumX MX460B: Compact data acquisition system/frequency counter module

The QuantumX MX460B frequency counter module collects digital pulse and frequency signals with high accuracy with 100MHz resolution and up to 100kS/s sampling rate. It has features that are ideal for the development of electric drives and allows extremely dynamic measurements of modern high-performance engines. QuantumX MX460B is a module that can simultaneously collect various mechanical quantities such as rotational speed, torque, angle, position, displacement, and pulse modulation, and enables data transmission with low loss. Achieving accuracy class 0.01, it provides highly detailed and highly reproducible measurement results. For example, if an emergency stop is required during a test bench load test, comprehensive safety functions can be tested using real-time torsional vibration analysis and differential angle calculations. The pulse and frequency modules have optimal compatibility with the QuantumX family and can also be connected as modules to existing measurement systems via Ethernet and FireWire. QuantumX MX460B supports HBM's torque sensors T12HP and T40B.

■Features

1. High precision ・Accuracy class 0.01 ・High resolution data acquisition at maximum sampling rate of 100kS/s for each channel ・Low noise measurement with active low-pass filter (Bessel, Butterworth, linear phase) ・High resolution and accurate measurement results 2. Multifunctional ・Supports digital pulse and frequency signals up to 1MHz Optimized acquisition and processing of rotational speed, torque, angle, position, displacement, and pulse width modulation ・The active sensor power supply voltage can be selected from 5 to 24 V for each channel. ・For demanding applications that require measurement of various parameters 3. Connectivity ・Angle-based analysis on a PC equipped with Catman software ・Automatic measurement point identification using TEDS ・Optimal integration with other QuantumX ・Easy connection to real-time PC for data analysis and automation environments *There are other features as well.

  • Product

    Frequency counter module QuantumX MX460B

Share this product


80+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Frequency counter module QuantumX MX460B

Image Part Number Price (excluding tax) Power consumption: No adjustable sensor input Power consumption Adjustable sensor input available Connectable sensors Synchronization option PROFINET Synchronization option IRIG-B Synchronization options IEEE1588, NTP Synchronization option EtherCAT® Nominal (rated) temperature range Input Signal bandwidth, maximum (-3dB) Supply voltage range (DC) Maximum supply voltage momentary interruption time (at 24V) Sensor identification Maximum distance to TEDS module Sensor identification Sensor connection Sensor applied voltage (active sensor) -2 Sensor applied voltage (active sensor) -1 Sampling rate Active low pass filter IEEE1394b FireWire-7 IEEE1394b FireWire-6 IEEE1394b FireWire-5 IEEE1394b FireWire-4 IEEE1394b FireWire-3 IEEE1394b FireWire-2 IEEE1394b FireWire-1 Ethernet (data link) -4 Ethernet (data link) -3 Ethernet (data link) -2 Ethernet (data link) -1
Frequency counter module QuantumX MX460B-Part Number-MX460B

MX460B

Available upon quote

6W

9W

Common digital pulse measurements: pulse counter, HBM torque sensor, speed recording (rpm) with inductive rotary encoder (AC coupled), etc.

Via CX27C

Via MX440A or MX840A input channels (B000 to B007; B120 to B127)

Ethernet-based network time protocol (IEEE1588 (PTPv2))

IEEE1394b FireWire (QuantumX only, automatic, recommended) (EtherCAT® is a patented registered trademark of Beckhoff Automation GmbH (Germany))

-20~+65℃

4. Electrically isolated between channels and from the power supply (when using variable sensor applied voltage, remove electrical isolation from the power supply)

0~40,000Hz (without filter) (Conditions: FM when F0=500kHz and AF=100kHz)

10~30V (nominal (rated) voltage 24V)

5ms (uninterruptible power supply (UPS) can be supplied as an accessory for longer interruptions)

100m

TEDS, IEEE 1451.4

D-SUB-15HD

Maximum output power: 0.7W per channel/total maximum 2W

Adjustable supply voltage (DC): 5~24V, adjustable per channel

Individually programmable for each channel: Decimal: 0.1~100,000S/s or Classic mode: 0.1~96,000S/s

Bessel, Butterworth, linear phase, no filter (filter off is only recommended for real-time applications (e.g. when low latency times are required))

Maximum number of hops in chain: 14 (inter-module synchronization, data link, supply voltage options)

Maximum number of modules in an IEEE1394b FireWire system (including hub and backplane): 24 (Hub: IEEE1394b FireWire node point or distributor)

Maximum number of connectable modules (consecutive): 12 (=11 hops) (inter-module synchronization, data link, supply voltage options) (hop: module-to-module transition/signal conditioning)

Maximum cable length between connections: 5m (optical 100) (inter-module synchronization, data link, supply voltage options)

Maximum current between modules: 1.5A (inter-module synchronization, data link, supply voltage options)

Baud rate: 400MBaud (approximately 50MBytes/s) (inter-module synchronization, data link, supply voltage options)

IEEE 1394b (inter-module synchronization, data link, supply voltage options)

Maximum cable length to module: 100m

Plug connection: 8P8C plug (RJ-45) with twisted pair cable (CAT-5)

Protocol (addressing): TCP/IP (fixed IP/DHCP, IPv4/IPv6)

10Base-T/100Base-TX

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Frequency Counters Products

Other products of Hottinger Brüel & Kjær

Reviews shown here are reviews of companies.


View more products of Hottinger Brüel & Kjær

About Company Handling This Product

Response Rate

100.0%


Response Time

22.7hrs


Company Review

5.0

Company Overview

HBK, formerly named HBM, is a global ISO9001 and ISO14001-certified company founded in 1950. It is known for p...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree