All Categories
History
Relatively Fast Response
Product
Pressure sensor P3 Top Class BlueLineHandling Company
Hottinger Brüel & KjærCategories
Image | Part Number | Price (excluding tax) | Deviation based on cubic interpolation by test series | Measurement range, 0bar~ | Measurement method | Self-volume including included packing | Self volume | Withstand voltage | Accuracy class | Effect of temperature change on zero point Ratio to measured value | Effect of temperature change on zero point Ratio to rated sensitivity | Output resistance at standard temperature | Input resistance at standard temperature | Sensitivity | Rated sensitivity | Pressure type | Natural frequency | Reference bridge applied voltage | Dynamic pressure Maximum dynamic vibration amplitude | Dynamic pressure Maximum dynamic pressure | Initial value Limit pressure at standard temperature | Initial value Operating range at standard temperature | Initial value Test pressure | Initial value | Protection class | Nonlinearity including hysteresis | Zero point error | Long-term stability of zero point and sensitivity (yearly) | Control volume | Creep (no load, 15 minutes) | Repeatability according to DIN 1319 | Insulation resistance at 100V AC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
P3 Top Class BlueLine |
Available upon quote |
0.25~0.05% (maximum value) |
5,000~15,000bar |
Foil strain gauge |
200mm3 (5,000bar only) |
100~615mm3 |
90V |
0.25~0.6 (Accuracy grade is HBM product specific grade, not based on DIN 16086) |
Temperature compensation range of 0℃ or higher: ±0.05%, temperature compensation range of 0℃ or less: ±0.1%, permissible temperature range: ±0.2% (per 10K in the rated range of bridge applied voltage) |
In the compensation temperature range: ±0.05%, in the allowable temperature range: ±0.10% (per 10K in the rated range of bridge applied voltage) |
350±1.5Ω |
350±5Ω |
<±0.2~±0.8% |
1mV/V |
Absolute pressure |
>100kHz |
5V |
3,500~6,000bar (based on DIN 50100) |
100% |
110~120% |
110~120% |
100~195% |
0bar |
IP67 |
0.25~0.6% |
<±1% |
0.20% |
Approximately 1mm3 |
<±0.03% |
<±0.05% |
5,000MΩ |
Reviews shown here are reviews of companies.