All Categories

History

Beam type load cell High precision load cell HLC-HLC A1
Beam type load cell High precision load cell HLC-HLC B1
Beam type load cell High precision load cell HLC-HLC B2
Beam type load cell High precision load cell HLC-Hottinger Brüel & Kjær

Beam type load cell High precision load cell HLC
Hottinger Brüel & Kjær

Hottinger Brüel & Kjær's Response Status

Response Rate

100.0%

Response Time

23.2hours

Relatively Fast Response


About This Product

■World standard for high-precision load cells

HBM's flagship load cell boasts high accuracy and robustness. Can be used for various purposes.

■Load cell HLC series: Highly durable type with accuracy class C6

The HLC series load cells are used in all types of platforms, conveyor scales, tank scales, etc. Many of our customers are market leaders in their industries. The HLC's 6-wire configuration guarantees accuracy class C6 according to OIML R60. This heavy-duty load cell HLC has standard dimensions and can easily be adapted to measure capacities up to 110kg to 10t. Furthermore, if necessary, protection class IP69K or IECEx-ATEX compliant explosion-proof specifications can be selected.

■Features

1. High precision ・Guaranteed up to accuracy class C6 (equivalent to OIML class III) ・6-wire configuration that can compensate for changes in resistance value and cable length ・Weighing system for commercial transactions with a maximum scale of 6,000 ・Optimization possible when connecting multiple load cells in parallel ・High accuracy that can also be used as a commercial weighing system and compatible with all applications 2. Robust ・Stainless steel load cell ・Optional TPE-0 cable sheath with extremely high chemical resistance ・Protection class IP68/IP69K ensures durability in constant humidity and high pressure environments ・Explosion-proof specifications can be selected (e.g. IECEx-ATEX-Zone 1/21) ・Durable design and explosion-proof specifications ensure high accuracy and robustness even in harsh environments 3. Flexible -This product version has uniform dimensions and a low height. ・Choose from 8 types of maximum capacity (110kg, 220kg, 550kg, 1.1t, 1.76t, 2.2t, 4.4t, 10t) - Approved to OIML R60 and other international standards. ・Easy and quick integration into existing platforms - Different cable types and lengths available. - Compatible with various specifications: different maximum capacities can be selected with the same standard dimensions

  • Product

    Beam type load cell High precision load cell HLC

Share this product


210+ people viewing

Last viewed: 48 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of Beam type load cell High precision load cell HLC

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Nonlinearity dlin Limit load EL Critical lateral stress Elq Weight (approximate) G Allowable temperature range Btu Allowable dynamic load Fsrel Insulation resistance Ris Breaking load Ed Temperature compensation range BT Material Minimum load output return MDLOR Minimum verification scale Vmin Deflection amount at maximum capacity load (approximate) Snom Maximum capacity Emax Maximum load cell division number nLC Sensitivity error Temperature coefficient for sensitivity TCs Sensitivity CN Reference bridge applied voltage Uref Output resistance R0 Input resistance RLC Protection class (IP) Storage temperature range Btl Bridge applied voltage range BU Hysteresis error dhy Temperature effect on zero point TC0 Creep, over 30 minutes dcr Y value Y Accuracy class based on OIML R60
Beam type load cell High precision load cell HLC-Part Number-HLC A1

HLC A1

Available upon quote

±0.0500~±0.0170 (% of Cn) (Nonlinearity values ​​are recommended values. These combined values ​​meet the cumulative error requirements specified in OIML R60)

150 (% of Emax)

100 (% of Emax)

0.9kg (110kg~1.76t), 1.6kg (2.2t), 2.2kg (4.4t), 6.2kg (10t)

-30~+70℃ (For use in potentially explosive environments: please refer to the safety precautions in the explosion protection standard)

70 (% of Emax) (Frequency and amplitude conditions are according to DIN 50100)

>5GΩ

300 (% of Emax)

-10~+40℃ (Use in potentially explosive environments: see safety precautions in explosion protection standards)

Stainless steel (according to EN10088-1), Stainless steel (according to EN10088-1) / Sealing material: Viton🄬, Cable covering: PVC

±0.0500~±0.0166 (% of Cn)

D1: 0.0285, 0.0100 (220kg, 1.76t, 2.2t, 4.4t), 0.0090 (110kg, 550kg, 1.1t) (% of Emax)

0.5mm (1.76t=1.4mm)

220kg~4.4t

1,000/3,000/4,000/6,000

D1: ±0.5, Others: ±0.1%

±0.0070~±0.0420 (% of Cn) (Temperature effect value on sensitivity is recommended value. These combined values ​​meet the cumulative error requirements specified in OIML R60)

1.94mV/V (10t=2.00mV/V)

5V (for use in potentially explosive environments: see safety instructions in explosion protection standards)

350±2Ω, 350±0.12Ω

350~480Ω

IP68 (according to EN 60529 (IEC 529))

-50~+85℃

0.5~15V (explosion-proof version up to 12V), 5~10V (for use in potentially explosive environments: refer to the safety precautions in the explosion-proof standard)

±0.0500~±0.0166 (% of Cn) (Hysteresis error value is recommended value. These combined values ​​meet the cumulative error requirements specified by OIML R60)

D1: ±0.0400, ±0.0140 (220kg, 1.76t, 2.2t, 4.4t), ±0.0126 (110kg, 550kg, 1.1t) (% of Cn/10K)

±0.0500~±0.0166 (% of Cn)

D1: 3,500, 10,000 (220kg, 1.76t, 2.2t, 4.4t), 11,111 (110kg, 550kg, 1.1t)

D1/C3

Beam type load cell High precision load cell HLC-Part Number-HLC B1

HLC B1

Available upon quote

±0.0500~±0.0170 (% of Cn) (Nonlinearity values ​​are recommended values. These combined values ​​meet the cumulative error requirements specified in OIML R60)

150 (% of Emax)

100 (% of Emax)

0.9kg (110kg~1.76t), 1.6kg (2.2t), 2.2kg (4.4t), 6.2kg (10t)

-30~+70℃ (For use in potentially explosive environments: please refer to the safety precautions in the explosion protection standard)

70 (% of Emax) (Frequency and amplitude conditions are according to DIN 50100)

>5GΩ

300 (% of Emax)

-10~+40℃ (Use in potentially explosive environments: see safety precautions in explosion protection standards)

Stainless steel (according to EN10088-1), Stainless steel (according to EN10088-1) / Sealing material: Viton🄬, Cable covering: PVC

±0.0500~±0.0166 (% of Cn)

D1: 0.0285, 0.0100 (220kg, 1.76t, 2.2t, 4.4t), 0.0090 (110kg, 550kg, 1.1t) (% of Emax)

0.5mm (1.76t=1.4mm)

D1: 110kg~10t, C3: 110kg~4.4t, C4/C6: 220kg~1.1t

1,000/3,000/4,000/6,000

D1: ±0.5, Others: ±0.1%

±0.0070~±0.0420 (% of Cn) (Temperature effect value on sensitivity is recommended value. These combined values ​​meet the cumulative error requirements specified in OIML R60)

1.94mV/V (10t=2.00mV/V)

5V (for use in potentially explosive environments: see safety instructions in explosion protection standards)

350±2Ω, 350±0.12Ω

350~480Ω

IP68 (according to EN 60529 (IEC 529))

-50~+85℃

0.5~15V (explosion-proof version up to 12V), 5~10V (for use in potentially explosive environments: refer to the safety precautions in the explosion-proof standard)

±0.0500~±0.0166 (% of Cn) (Hysteresis error value is recommended value. These combined values ​​meet the cumulative error requirements specified by OIML R60)

D1: ±0.0400, ±0.0140 (220kg, 1.76t, 2.2t, 4.4t), ±0.0126 (110kg, 550kg, 1.1t) (% of Cn/10K)

±0.0500~±0.0166 (% of Cn)

D1: 3,500, 10,000 (220kg, 1.76t, 2.2t, 4.4t), 11,111 (110kg, 550kg, 1.1t)

D1/C3/C4/C6 (accuracy class C4/C6 only for HLCB1/220kg, 550kg, 1.1t)

Beam type load cell High precision load cell HLC-Part Number-HLC B2

HLC B2

Available upon quote

±0.0500~±0.0170 (% of Cn) (Nonlinearity values ​​are recommended values. These combined values ​​meet the cumulative error requirements specified in OIML R60)

150 (% of Emax) (For 1.76t: 171% of Emax)

100 (% of Emax)

0.9kg (110kg~1.76t), 1.6kg (2.2t), 2.2kg (4.4t)

-30~+70℃ (For use in potentially explosive environments: please refer to the safety precautions in the explosion protection standard)

70 (% of Emax) (For 1.76t: 600kg~2t, frequency and amplitude conditions are according to DIN 50100)

>5GΩ

300 (% of Emax)

-10~+40℃ (Use in potentially explosive environments: see safety precautions in explosion protection standards)

Stainless steel (according to EN10088-1), Stainless steel (according to EN10088-1) / Sealing material: Viton🄬, Cable covering: PVC

±0.0500~±0.0166 (% of Cn)

D1: 0.0285, 0.0100 (220kg, 1.76t, 2.2t, 4.4t), 0.0090 (110kg, 550kg, 1.1t) (% of Emax)

0.5mm (1.76t=1.4mm)

D1: 220kg~4.4t, C3: 110~4.4t, C4/C6: 220kg~1.1t

1,000/3,000/4,000/6,000

D1: ±0.5, Others: ±0.1%

±0.0070~±0.0420 (% of Cn) (Temperature effect value on sensitivity is recommended value. These combined values ​​meet the cumulative error requirements specified in OIML R60)

1.94mV/V

5V (for use in potentially explosive environments: see safety instructions in explosion protection standards)

350±2Ω, 350±0.12Ω

350~480Ω

IP68/IP69K (according to EN 60529 (IEC 60529))

-50~+85℃

0.5~15V (explosion-proof version up to 12V), 5~10V (for use in potentially explosive environments: refer to the safety precautions in the explosion-proof standard)

±0.0500~±0.0166 (% of Cn) (Hysteresis error value is recommended value. These combined values ​​meet the cumulative error requirements specified by OIML R60)

D1: ±0.0400, ±0.0140 (220kg, 1.76t, 2.2t, 4.4t), ±0.0126 (110kg, 550kg, 1.1t) (% of Cn/10K)

±0.0500~±0.0166 (% of Cn)

D1: 3,500, 10,000 (220kg, 1.76t, 2.2t, 4.4t), 11,111 (110kg, 550kg, 1.1t)

D1/C3/C4/C6 (PLC=0.7)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Load Cells Products

Other products of Hottinger Brüel & Kjær

Reviews shown here are reviews of companies.


View more products of Hottinger Brüel & Kjær

About Company Handling This Product

Response Rate

100.0%


Response Time

23.2hrs


Company Review

5.0

Company Overview

HBK, formerly named HBM, is a global ISO9001 and ISO14001-certified company founded in 1950. It is known for p...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree