All Categories
History
Relatively Fast Response
Product
Beam type load cell High precision load cell HLCHandling Company
Hottinger Brüel & KjærCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Nonlinearity dlin | Limit load EL | Critical lateral stress Elq | Weight (approximate) G | Allowable temperature range Btu | Allowable dynamic load Fsrel | Insulation resistance Ris | Breaking load Ed | Temperature compensation range BT | Material | Minimum load output return MDLOR | Minimum verification scale Vmin | Deflection amount at maximum capacity load (approximate) Snom | Maximum capacity Emax | Maximum load cell division number nLC | Sensitivity error | Temperature coefficient for sensitivity TCs | Sensitivity CN | Reference bridge applied voltage Uref | Output resistance R0 | Input resistance RLC | Protection class (IP) | Storage temperature range Btl | Bridge applied voltage range BU | Hysteresis error dhy | Temperature effect on zero point TC0 | Creep, over 30 minutes dcr | Y value Y | Accuracy class based on OIML R60 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HLC A1 |
Available upon quote |
±0.0500~±0.0170 (% of Cn) (Nonlinearity values are recommended values. These combined values meet the cumulative error requirements specified in OIML R60) |
150 (% of Emax) |
100 (% of Emax) |
0.9kg (110kg~1.76t), 1.6kg (2.2t), 2.2kg (4.4t), 6.2kg (10t) |
-30~+70℃ (For use in potentially explosive environments: please refer to the safety precautions in the explosion protection standard) |
70 (% of Emax) (Frequency and amplitude conditions are according to DIN 50100) |
>5GΩ |
300 (% of Emax) |
-10~+40℃ (Use in potentially explosive environments: see safety precautions in explosion protection standards) |
Stainless steel (according to EN10088-1), Stainless steel (according to EN10088-1) / Sealing material: Viton🄬, Cable covering: PVC |
±0.0500~±0.0166 (% of Cn) |
D1: 0.0285, 0.0100 (220kg, 1.76t, 2.2t, 4.4t), 0.0090 (110kg, 550kg, 1.1t) (% of Emax) |
0.5mm (1.76t=1.4mm) |
220kg~4.4t |
1,000/3,000/4,000/6,000 |
D1: ±0.5, Others: ±0.1% |
±0.0070~±0.0420 (% of Cn) (Temperature effect value on sensitivity is recommended value. These combined values meet the cumulative error requirements specified in OIML R60) |
1.94mV/V (10t=2.00mV/V) |
5V (for use in potentially explosive environments: see safety instructions in explosion protection standards) |
350±2Ω, 350±0.12Ω |
350~480Ω |
IP68 (according to EN 60529 (IEC 529)) |
-50~+85℃ |
0.5~15V (explosion-proof version up to 12V), 5~10V (for use in potentially explosive environments: refer to the safety precautions in the explosion-proof standard) |
±0.0500~±0.0166 (% of Cn) (Hysteresis error value is recommended value. These combined values meet the cumulative error requirements specified by OIML R60) |
D1: ±0.0400, ±0.0140 (220kg, 1.76t, 2.2t, 4.4t), ±0.0126 (110kg, 550kg, 1.1t) (% of Cn/10K) |
±0.0500~±0.0166 (% of Cn) |
D1: 3,500, 10,000 (220kg, 1.76t, 2.2t, 4.4t), 11,111 (110kg, 550kg, 1.1t) |
D1/C3 |
|
HLC B1 |
Available upon quote |
±0.0500~±0.0170 (% of Cn) (Nonlinearity values are recommended values. These combined values meet the cumulative error requirements specified in OIML R60) |
150 (% of Emax) |
100 (% of Emax) |
0.9kg (110kg~1.76t), 1.6kg (2.2t), 2.2kg (4.4t), 6.2kg (10t) |
-30~+70℃ (For use in potentially explosive environments: please refer to the safety precautions in the explosion protection standard) |
70 (% of Emax) (Frequency and amplitude conditions are according to DIN 50100) |
>5GΩ |
300 (% of Emax) |
-10~+40℃ (Use in potentially explosive environments: see safety precautions in explosion protection standards) |
Stainless steel (according to EN10088-1), Stainless steel (according to EN10088-1) / Sealing material: Viton🄬, Cable covering: PVC |
±0.0500~±0.0166 (% of Cn) |
D1: 0.0285, 0.0100 (220kg, 1.76t, 2.2t, 4.4t), 0.0090 (110kg, 550kg, 1.1t) (% of Emax) |
0.5mm (1.76t=1.4mm) |
D1: 110kg~10t, C3: 110kg~4.4t, C4/C6: 220kg~1.1t |
1,000/3,000/4,000/6,000 |
D1: ±0.5, Others: ±0.1% |
±0.0070~±0.0420 (% of Cn) (Temperature effect value on sensitivity is recommended value. These combined values meet the cumulative error requirements specified in OIML R60) |
1.94mV/V (10t=2.00mV/V) |
5V (for use in potentially explosive environments: see safety instructions in explosion protection standards) |
350±2Ω, 350±0.12Ω |
350~480Ω |
IP68 (according to EN 60529 (IEC 529)) |
-50~+85℃ |
0.5~15V (explosion-proof version up to 12V), 5~10V (for use in potentially explosive environments: refer to the safety precautions in the explosion-proof standard) |
±0.0500~±0.0166 (% of Cn) (Hysteresis error value is recommended value. These combined values meet the cumulative error requirements specified by OIML R60) |
D1: ±0.0400, ±0.0140 (220kg, 1.76t, 2.2t, 4.4t), ±0.0126 (110kg, 550kg, 1.1t) (% of Cn/10K) |
±0.0500~±0.0166 (% of Cn) |
D1: 3,500, 10,000 (220kg, 1.76t, 2.2t, 4.4t), 11,111 (110kg, 550kg, 1.1t) |
D1/C3/C4/C6 (accuracy class C4/C6 only for HLCB1/220kg, 550kg, 1.1t) |
|
HLC B2 |
Available upon quote |
±0.0500~±0.0170 (% of Cn) (Nonlinearity values are recommended values. These combined values meet the cumulative error requirements specified in OIML R60) |
150 (% of Emax) (For 1.76t: 171% of Emax) |
100 (% of Emax) |
0.9kg (110kg~1.76t), 1.6kg (2.2t), 2.2kg (4.4t) |
-30~+70℃ (For use in potentially explosive environments: please refer to the safety precautions in the explosion protection standard) |
70 (% of Emax) (For 1.76t: 600kg~2t, frequency and amplitude conditions are according to DIN 50100) |
>5GΩ |
300 (% of Emax) |
-10~+40℃ (Use in potentially explosive environments: see safety precautions in explosion protection standards) |
Stainless steel (according to EN10088-1), Stainless steel (according to EN10088-1) / Sealing material: Viton🄬, Cable covering: PVC |
±0.0500~±0.0166 (% of Cn) |
D1: 0.0285, 0.0100 (220kg, 1.76t, 2.2t, 4.4t), 0.0090 (110kg, 550kg, 1.1t) (% of Emax) |
0.5mm (1.76t=1.4mm) |
D1: 220kg~4.4t, C3: 110~4.4t, C4/C6: 220kg~1.1t |
1,000/3,000/4,000/6,000 |
D1: ±0.5, Others: ±0.1% |
±0.0070~±0.0420 (% of Cn) (Temperature effect value on sensitivity is recommended value. These combined values meet the cumulative error requirements specified in OIML R60) |
1.94mV/V |
5V (for use in potentially explosive environments: see safety instructions in explosion protection standards) |
350±2Ω, 350±0.12Ω |
350~480Ω |
IP68/IP69K (according to EN 60529 (IEC 60529)) |
-50~+85℃ |
0.5~15V (explosion-proof version up to 12V), 5~10V (for use in potentially explosive environments: refer to the safety precautions in the explosion-proof standard) |
±0.0500~±0.0166 (% of Cn) (Hysteresis error value is recommended value. These combined values meet the cumulative error requirements specified by OIML R60) |
D1: ±0.0400, ±0.0140 (220kg, 1.76t, 2.2t, 4.4t), ±0.0126 (110kg, 550kg, 1.1t) (% of Cn/10K) |
±0.0500~±0.0166 (% of Cn) |
D1: 3,500, 10,000 (220kg, 1.76t, 2.2t, 4.4t), 11,111 (110kg, 550kg, 1.1t) |
D1/C3/C4/C6 (PLC=0.7) |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.