All Categories
History
Relatively Fast Response
Product
Small single point load cell for large loads PW10AHandling Company
Hottinger Brüel & KjærCategories
Image | Part Number | Price (excluding tax) | Nonlinearity dlin | Static critical lateral stress Elq | Limit load EL | Weight (approximate) m | Allowable temperature range Btu | Insulation resistance Ris (at 100VDC) | Accuracy class | Breaking load Ed | Temperature compensation range BT | Material | Ratio of minimum verification scale Y | Minimum verification scale vmin | Maximum loading surface | Maximum capacity Emax | Maximum applied voltage | Maximum load cell division number nLC | Temperature effect on sensitivity TCs | Sensitivity Cn | Reference bridge applied voltage Uref | Output resistance R0 | Input resistance RLC | Eccentricity (off-center) error | Protection class | Storage temperature range Btl | Bridge applied voltage range BU | Hysteresis error dhy | Temperature effect on zero point TC0 | Zero point | Displacement at Emax (approximate) Snom |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PW10A |
Available upon quote |
±0.0166 (% of Cn) (The sum of the values of nonlinearity dlin, hysteresis error dhy, and temperature influence TCs on sensitivity meets the requirements for porting error specified in OIMLR60) |
300 (% of Emax) |
Maximum position 100mm away from load center: 150 (% of Emax) |
0.6kg |
-10~+50℃ |
>2GΩ |
Based on OIML R60 PLC=0.7 C3 Multi-Range (MR) |
300 (% of Emax) |
-10~+40℃ |
Rigid body: Aluminum, Gauge protection: Silicone rubber, Cable covering: PVC |
10,000~15,000 |
5~20g (accuracy class C3MR) |
600×500mm |
50kg~300kg (maximum eccentric load according to OIML R76) |
15V |
3,000 |
|
2.0±0.2mV/V (Option 6: A=2mV/V±0.1%) |
5V |
300~500Ω (Option 6: A=410Ω±0.2Ω) |
300~500Ω |
±0.0233 (according to OIML R76) |
IP67 (IEC529 compliant) |
-25~+70℃ |
1~12V |
±0.0166 (% of Cn) (The sum of the values of nonlinearity dlin, hysteresis error dhy, and temperature influence TCs on sensitivity meets the requirements for porting error specified in OIMLR60) |
±0.0093~0.0140 (% of Cn/10K) (accuracy grade C3MR) |
0±0.1mV/V |
<0.5mm |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.