Single point load cell SP4M/PW15-SP4M
Single point load cell SP4M/PW15-PW15B
Single point load cell SP4M/PW15-PW15AH/PW15AHY
Single point load cell SP4M/PW15-PW15PH
Single point load cell SP4M/PW15-Hottinger Brüel & Kjær

Single point load cell SP4M/PW15
Hottinger Brüel & Kjær

Hottinger Brüel & Kjær's Response Status

Response Rate

100.0%

Response Time

22.7hours

Relatively Fast Response


About This Product

■Single point load cell SP4M/PW15 - Maximum capacity 200kg, protection class IP68/IP69K

Load cells PW15 and SP4M have the same loading surface but different features, and their high flexibility allows platform scale designs for a wide range of applications. It is an ideal weighing component for conveyor scales, floor scales, table scales, etc., as well as for integration into filling and production systems. In addition to the food, packaging, and chemical fields, they are used in a wide variety of applications including trade and agriculture.

■Features

1. Highly accurate weighing for a wide range of applications ・Highly versatile and flexible platform scale design possible ・Eccentricity (off-center) error correction (OIML R76) ・High stability with 6-wire system ・High noise resistance ・Test report included (OIML R60) ・Minimum verification interval for multi-range applications ・Long track record in various fields 2. Easy to customize ・Maximum capacity: 1-200kg ・Space-saving and easy to integrate ・Made of stainless steel or lightweight aluminum ・Robust, protection class IP68/IP69K ・Explosion-proof model ・Cable and plug protection ・Minimization of output error, ideal for parallel connection ・Optimal solution for platform scale design/manufacturing for each application 3. Special accessories ・Various cable lengths ・Various cable materials (PVC, PUR) - Can be used immediately after installation with connection cables designed for various applications and measurement conditions.

■Special accessories/options

・Minimization of output error, ideal for parallel connection ・Explosion-proof model ・Various cable lengths/characteristics

  • Product

    Single point load cell SP4M/PW15

Share this product


320+ people viewing

Last viewed: 22 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of Single point load cell SP4M/PW15

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Nonlinearity dlin Static critical lateral stress Elq Limit load EL Mass (approximate) m Allowable load EU Allowable temperature range Btu Accuracy grade/minimum verification scale (Y) Breaking load Ed Relative allowable dynamic load Fsrel Temperature compensation range BT Minimum load output return MDLOR Ratio of minimum verification scale Y Minimum verification scale vmin Maximum loading surface Deflection amount at maximum capacity load (approximate) Snom Maximum capacity Emax Maximum applied voltage Maximum load cell division number nLC Temperature effect on sensitivity Sensitivity Cn Reference bridge applied voltage Uref Output resistance R0 Input resistance RLC Eccentricity (off-center) error Storage temperature range Btl Bridge applied voltage range BU Hysteresis error dhy Temperature effect on zero point TC0 Zero point Insulation resistance Ris at 100VDC
Single point load cell SP4M/PW15-Part Number-SP4M

SP4M

Available upon quote

±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values ​​meet the cumulative error requirements specified in OIML R60)

300 (% of Emax)

Up to 100mm away from center: 150 (% of Emax)

0.45kg

Up to 100mm away from center: 150 (% of Emax)

-0~+50℃

C3 Multi-Range (MR)

Position 20mm away from center: 300 (% of Emax)

Up to 20mm away from center: 70 (% of Emax)

-10~+40℃

±0.0166 (% of Cn)

10,000~15,000

0.1~20g

300×300/450×450/600×600mm

<0.5mm, <0.3mm, <0.25mm

1~200kg

15V

3,000

Maximum capacity 1kg: 1.8+0.27₋0.18mV/V (Option 6: A=1.8mV/V±0.1%), Maximum capacity 3~200kg: 2.0±0.2mV/V (Option 6: A=2mV/V± 0.1%)

5V

300~500Ω (Option 6: A=410Ω±0.2Ω)

300~500Ω

±0.0233 (according to OIML R76)

-25~+70℃

1~12V

±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values ​​meet the cumulative error requirements specified in OIML R60)

±0.0093~0.0140 (Cn%/10K)

0±0.1mV/V

>2GΩ

Single point load cell SP4M/PW15-Part Number-PW15B

PW15B

Available upon quote

±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values ​​meet the cumulative error requirements specified in OIML R60)

300 (% of Emax)

Up to 160mm away from center: 150 (% of Emax)

1kg

Up to 100mm away from center: 150 (% of Emax)

-10~+50℃

C3 Multi-Range (MR)

Position 20mm away from center: 300 (% of Emax)

Up to 20mm away from center: 70 (% of Emax)

-10~+40℃

±0.0166 (% of Cn)

10,000~15,000

0.5~20g

500×400mm

0.17mm~0.21mm

7.5~200kg

15V

3,000

2.0±0.2mV/V (Option 6: 2.0mV/V±0.1%)

5V

300~500Ω (Option 6: 359±0.2)

300~500Ω

≦233ppm (according to OIML R76)

-25~+70℃

1~12V

±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values ​​meet the cumulative error requirements specified in OIML R60)

±0.0093~0.0140 (Cn%/10K)

0±0.1mV/V

>1GΩ

Single point load cell SP4M/PW15-Part Number-PW15AH/PW15AHY

PW15AH/PW15AHY

Available upon quote

±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values ​​meet the cumulative error requirements specified in OIML R60)

300 (% of Emax)

Up to 160mm away from center: 150 (% of Emax), 160mm

1.0kg

Up to 100mm away from center: 150 (% of Emax)

-10~+50℃ (+14~+122℉)

C3 multi-range, Y value up to 10,000

Position 20mm away from center: 300 (% of Emax)

Up to 20mm away from center: 70 (% of Emax)

-10~+40℃ (+14~+104℉)

±0.0166 (% of Cn)

10000/20,000~25,000

1~10g/0.5~5

500×400mm

<0.5mm

10~100kg

15V

3,000

2.0±0.2mV/V

5V

300~500Ω

300~500Ω

±0.0233 (according to OIML R76)

-25~+70℃ (-13~+158℉)

1~12V

±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values ​​meet the cumulative error requirements specified in OIML R60)

±0.0140/±0.0056~±0.0070 (% of Cn/10K)

0±0.1mV/V

>1GΩ

Single point load cell SP4M/PW15-Part Number-PW15PH

PW15PH

Available upon quote

±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values ​​meet the cumulative error requirements specified in OIML R60)

300 (% of Emax)

Up to 160mm away from center: 150 (% of Emax)

0.9kg

Up to 100mm away from center: 150 (% of Emax)

-10~+50℃

C3 multi-range, Y value up to 10,000

Position 20mm away from center: 300 (% of Emax)

Up to 20mm away from center: 70 (% of Emax)

-10~+40℃

±0.0166 (% of Cn)

10,000

1~10g

500×400mm

<0.5mm

10~100kg

15V

3,000

2.0±0.2mV/V

5V

300~500Ω

300~500Ω

±0.0166 (according to OIML R76)

-25~+70℃

1~12V

±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values ​​meet the cumulative error requirements specified in OIML R60)

±0.0140 (% of Cn/10K)

0±0.1mV/V

>1GΩ

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Load Cells Products

Other products of Hottinger Brüel & Kjær

Reviews shown here are reviews of companies.


View more products of Hottinger Brüel & Kjær

About Company Handling This Product

Response Rate

100.0%


Response Time

22.7hrs


Company Review

5.0

Company Overview

HBK, formerly named HBM, is a global ISO9001 and ISO14001-certified company founded in 1950. It is known for p...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree