All Categories

History

Single point load cell PW29-PW29
Single point load cell PW29-PW29P
Single point load cell PW29-Hottinger Brüel & Kjær

Single point load cell PW29
Hottinger Brüel & Kjær


About This Product

■PW29

The fully enclosed PW29 is a single point load cell designed for large weighing platforms with high maximum load capacity.

■PW29: Completely sealed structure PW29 is a high single point load cell

The fully enclosed PW29 is a single point load cell designed for large weighing platforms with high maximum load capacity. This load cell is made of stainless steel and is ideal for situations where heavy objects must be weighed accurately, such as in the food and beverage industry and the pharmaceutical industry. The PW29 provides reliable measurement results that comply with OIML R60 regulations, even under the harshest operating conditions. This is made possible by the latest housing design, strain gage system and robust design optimized for this instrument. Furthermore, PW29 complies with the current highest level of protection class IP68/IP69K. There is no need to worry about trouble even in dusty environments. Can also be used in applications exposed to water or moisture. Even if you use a high-pressure washer or strong detergent to clean it, the load cell will continue to function normally without being affected in any way. Whether for traditional scale, plant engineering or food manufacturing, the PW29 is designed to be ideal for large platforms. Moreover, only one HBM load cell is required for installation. This single-point load cell provides accurate weighing on rail, tabletop, floor, and belt conveyor scales, as well as when weighing in production systems and in tanks for horizontal monitoring. We provide measurement results reliably. All PW29 models meet the C3MR accuracy class. We also provide OIML compliance certificates for load cells. In this way, the PW29 load cell has optimal performance as a scale suitable for commercial transactions. In addition to adjustable overload protection, four screw holes for fixing the load cell and mounting the weighing platform ensure high mechanical reliability. For maximum allowable loads of 500kg and above, M12 screws are used. An integrated threaded adapter makes it easy to use cable protection systems.

  • Product

    Single point load cell PW29

Share this product


320+ people viewing

Last viewed: 4 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of Single point load cell PW29

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Nonlinearity dlin Static critical lateral stress Elq Limit load EL Mass (approximate) m Allowable temperature range Btu Accuracy class Breaking load Ed Temperature compensation range BT Minimum load output return MDLOR Ratio of minimum verification scale Y Minimum verification scale vmin Maximum loading surface Maximum capacity Emax Maximum applied voltage Maximum load cell division number nLC Sensitivity Cn Reference bridge applied voltage Uref Output resistance R0 Input resistance RLC Eccentricity (off-center) error Protection class Storage temperature range Btl Bridge applied voltage range BU Hysteresis error dhy Error relative to zero point Temperature effect on zero point TK0 Deflection amount snom Deflection amount sexz Temperature effect on sensitivity per 10K TKc Insulation resistance Ris at 100VDC
Single point load cell PW29-Part Number-PW29

PW29

Available upon quote

±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values ​​meet the cumulative error requirements specified in OIML R60)

300 (% of Emax)

Up to 100mm away from center: 150

6.3kg

-10~+50℃

C3 Multi-Range (MR)

300 (% of Emax)

-10~+40℃

±0.0166 (% of Cn)

7,500/10,000/12,500

10/20/50/100g

800×800mm

100/250/500/750/1,000kg

15V

3,000

2.0±0.2mV/V

5V

300~500W

380±15W

≦233ppm (according to OIML R76)

IP68 (load test conditions: 100 hours immersion in a water tank at a depth of 1 m), IP69K (high pressure water, steam jet cleaning) (based on EN 60529 (IEC 529))

-25~+70℃

1~12V

±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values ​​meet the cumulative error requirements specified in OIML R60)

±0.1mV/V

±0.0112/0.0140/0.0186 (%Cn/10K)

<0.2~0.3mm (When the load is applied at Emax at the center of gravity of the load cell)

<0.1~0.3mm (at 1/3 Emax and 283mm away from the center)

>2GΩ

Single point load cell PW29-Part Number-PW29P

PW29P

Available upon quote

±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values ​​meet the cumulative error requirements specified in OIML R60)

300 (% of Emax)

Up to 100mm away from center: 150

6.3kg

-10~+50℃

C3 Multi-Range (MR)

300 (% of Emax)

-10~+40℃

±0.0166 (% of Cn)

7,500/10,000/12,500

10/20/50/100g

800×800mm

100/250/500/750/1,000kg

15V

3,000

2.0±0.2mV/V

5V

300~500W

300~500W

≦233ppm (according to OIML R76)

IP68 (load test conditions: 100 hours immersion in a water tank at a depth of 1 m), IP69K (high pressure water, steam jet cleaning) (based on EN 60529 (IEC 529))

-25~+70℃

1~12V

±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values ​​meet the cumulative error requirements specified in OIML R60)

±0.1mV/V

±0.0112/0.0140/0.0186 (%Cn/10K)

<0.2~0.3mm (When the load is applied at Emax at the center of gravity of the load cell)

<0.1~0.3mm (at 1/3 Emax and 283mm away from the center)

>2GW

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Load Cells Products

Other products of Hottinger Brüel & Kjær

Reviews shown here are reviews of companies.


View more products of Hottinger Brüel & Kjær

About Company Handling This Product

Company Overview

HBK, formerly named HBM, is a global ISO9001 and ISO14001-certified company founded in 1950. It is known for p...

See More